Ida Bagus Gede Hermawan Manuaba, Mohammad Aljishi, Marie Van Steene, James Dolan
{"title":"Logging-While-Drilling Laterolog vs. Electromagnetic Propagation Measurements: Which Is Telling the True Resistivity?","authors":"Ida Bagus Gede Hermawan Manuaba, Mohammad Aljishi, Marie Van Steene, James Dolan","doi":"10.2118/219772-pa","DOIUrl":null,"url":null,"abstract":"\n The electromagnetic propagation (EMP) measurement frequently acquired with logging-while-drilling (LWD) tools in high-angle wells is sensitive to geometrical effects that can mask the true formation resistivity. Less commonly used, the LWD laterolog measurement is sometimes perceived as providing data too shallow to give a true formation resistivity (Rt). In this paper, we presents modeling and actual examples to demonstrate that the laterolog can often provide a superior resistivity measurement for formation evaluation to that of the LWD EMP tool.\n We examine the laterolog and EMP resistivities in several high-angle wells crossing carbonate formations in 8.5-in. and 6.125-in. hole sizes. In the 8.5-in. sections, producers and water injectors (high- and low-resistivity ranges) were evaluated. In the 6.125-in. sections, one reservoir sandwiched between two very high-resistivity layers and another borehole in a highly fractured reservoir were examined. The laterolog data were corrected for invasion using a 1D inversion of the memory data. Structure-based forward modeling was used to examine and explain the differences between the laterolog and EMP resistivity measurements.\n In the first example in a thick low-resistivity water reservoir, laterolog resistivity and EMP resistivity agree, showing that the two tools provide the same measurement when no geometrical effects are present.\n In the first part of the second example, a reservoir zone was initially drilled only with the LWD EMP resistivity measurement. The LWD laterolog was run several days later, and the resistivity data read much lower in the relogged section compared with the EMP resistivity. The laterolog 1D inversion was unable to resolve Rt because of the excessively deep invasion that occurred over the course of several days.\n In the second part of the second example, the laterolog resistivity showed a clear conductive invasion profile. While the deepest laterolog real-time resistivity data indicated lower resistivity than the EMP resistivity, the true resistivity, Rt (invasion-corrected 1D-inverted laterolog resistivity), matched the EMP Rt resistivity. This result validated both measurements and emphasized that the differences were due to invasion.\n The first two examples demonstrated that when acquired in normal drilling conditions (within 1–2 hours of drilling the section), the laterolog measurements can provide uninvaded formation resistivity even in the presence of invasion.\n A reservoir in another example was sandwiched between resistive layers that caused difficult-to-explain elevated EMP resistivity readings. Structural modeling reproduced the elevated behavior of the EMP data and explained the differences between resistivity measurements. This result showed that the laterolog is better suited to evaluate resistivity in thin reservoirs where there is a high-resistivity contrast to the adjacent layer.\n Finally, fractured reservoir examples are presented, which show that both the laterolog and EMP can be affected by the presence of fracture swarms.\n The examples presented in this paper demonstrate that in high-angle wells, when acquired under normal drilling conditions, invasion-corrected laterolog resistivity is often nearer to Rt than EMP resistivity. In those cases, the laterolog measurement provides data that are better inputs to water saturation calculations. Multiple examples from high-angle wells illustrate the findings.","PeriodicalId":22252,"journal":{"name":"SPE Journal","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPE Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2118/219772-pa","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, PETROLEUM","Score":null,"Total":0}
引用次数: 0
Abstract
The electromagnetic propagation (EMP) measurement frequently acquired with logging-while-drilling (LWD) tools in high-angle wells is sensitive to geometrical effects that can mask the true formation resistivity. Less commonly used, the LWD laterolog measurement is sometimes perceived as providing data too shallow to give a true formation resistivity (Rt). In this paper, we presents modeling and actual examples to demonstrate that the laterolog can often provide a superior resistivity measurement for formation evaluation to that of the LWD EMP tool.
We examine the laterolog and EMP resistivities in several high-angle wells crossing carbonate formations in 8.5-in. and 6.125-in. hole sizes. In the 8.5-in. sections, producers and water injectors (high- and low-resistivity ranges) were evaluated. In the 6.125-in. sections, one reservoir sandwiched between two very high-resistivity layers and another borehole in a highly fractured reservoir were examined. The laterolog data were corrected for invasion using a 1D inversion of the memory data. Structure-based forward modeling was used to examine and explain the differences between the laterolog and EMP resistivity measurements.
In the first example in a thick low-resistivity water reservoir, laterolog resistivity and EMP resistivity agree, showing that the two tools provide the same measurement when no geometrical effects are present.
In the first part of the second example, a reservoir zone was initially drilled only with the LWD EMP resistivity measurement. The LWD laterolog was run several days later, and the resistivity data read much lower in the relogged section compared with the EMP resistivity. The laterolog 1D inversion was unable to resolve Rt because of the excessively deep invasion that occurred over the course of several days.
In the second part of the second example, the laterolog resistivity showed a clear conductive invasion profile. While the deepest laterolog real-time resistivity data indicated lower resistivity than the EMP resistivity, the true resistivity, Rt (invasion-corrected 1D-inverted laterolog resistivity), matched the EMP Rt resistivity. This result validated both measurements and emphasized that the differences were due to invasion.
The first two examples demonstrated that when acquired in normal drilling conditions (within 1–2 hours of drilling the section), the laterolog measurements can provide uninvaded formation resistivity even in the presence of invasion.
A reservoir in another example was sandwiched between resistive layers that caused difficult-to-explain elevated EMP resistivity readings. Structural modeling reproduced the elevated behavior of the EMP data and explained the differences between resistivity measurements. This result showed that the laterolog is better suited to evaluate resistivity in thin reservoirs where there is a high-resistivity contrast to the adjacent layer.
Finally, fractured reservoir examples are presented, which show that both the laterolog and EMP can be affected by the presence of fracture swarms.
The examples presented in this paper demonstrate that in high-angle wells, when acquired under normal drilling conditions, invasion-corrected laterolog resistivity is often nearer to Rt than EMP resistivity. In those cases, the laterolog measurement provides data that are better inputs to water saturation calculations. Multiple examples from high-angle wells illustrate the findings.
期刊介绍:
Covers theories and emerging concepts spanning all aspects of engineering for oil and gas exploration and production, including reservoir characterization, multiphase flow, drilling dynamics, well architecture, gas well deliverability, numerical simulation, enhanced oil recovery, CO2 sequestration, and benchmarking and performance indicators.