{"title":"Quantitative reduction of iron under nitrogen atmosphere for potassium dichromate titration","authors":"Yuto Kadowaki, Yoko Yanagihara, Arinori Inagawa, Nobuo Uehara","doi":"10.2355/isijinternational.isijint-2024-066","DOIUrl":null,"url":null,"abstract":"</p><p>Total iron contents in iron ores have been accurately determined by JIS M 8212, in which iron ions in digested solutions of iron ores are reduced to divalent prior to redox titration. It is necessary for the iron reduction process that no reducing chemicals other than iron(II) in the decomposition solutions must not remain after the reduction with titanium(III). However, the redox reactions concerning the chemical species present in the decomposition solution has not been completely elucidated at the present time. In this paper, the redox reactions that occurred in the decomposition solution during the iron reduction in JIS M 8212 were studied by potentiometry and spectrophotometry under nitrogen atmosphere. The redox reaction of tin(II)/(IV) was very slow, causing significant effects on identifying the end point of the indicator for the iron reduction. The copper chloro-complexes were reduced with titanium(III) at a potential higher than that of indigo carmine used as a redox indicator, so that the reduced copper(I) gave a positive error to the potassium dichromate titration. The pentavalent vanadium was reduced with titanium (III) to form a complex with titanium, which also interfered with the potassium dichromate titration positively. To avoid these interferences, titanium(III) chloride was stoichiometrically added to the reaction mixture after addition of tin(II) chloride under nitrogen atmosphere so as to reduce only iron to divalent prior to the following redox titration. Combination of the proposed protocol with the potassium dichromate titration could successfully determine the iron content of certified reference materials of iron ores.</p>\n<p></p>","PeriodicalId":14619,"journal":{"name":"Isij International","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Isij International","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.2355/isijinternational.isijint-2024-066","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
引用次数: 0
Abstract
Total iron contents in iron ores have been accurately determined by JIS M 8212, in which iron ions in digested solutions of iron ores are reduced to divalent prior to redox titration. It is necessary for the iron reduction process that no reducing chemicals other than iron(II) in the decomposition solutions must not remain after the reduction with titanium(III). However, the redox reactions concerning the chemical species present in the decomposition solution has not been completely elucidated at the present time. In this paper, the redox reactions that occurred in the decomposition solution during the iron reduction in JIS M 8212 were studied by potentiometry and spectrophotometry under nitrogen atmosphere. The redox reaction of tin(II)/(IV) was very slow, causing significant effects on identifying the end point of the indicator for the iron reduction. The copper chloro-complexes were reduced with titanium(III) at a potential higher than that of indigo carmine used as a redox indicator, so that the reduced copper(I) gave a positive error to the potassium dichromate titration. The pentavalent vanadium was reduced with titanium (III) to form a complex with titanium, which also interfered with the potassium dichromate titration positively. To avoid these interferences, titanium(III) chloride was stoichiometrically added to the reaction mixture after addition of tin(II) chloride under nitrogen atmosphere so as to reduce only iron to divalent prior to the following redox titration. Combination of the proposed protocol with the potassium dichromate titration could successfully determine the iron content of certified reference materials of iron ores.
铁矿石中的总铁含量已通过 JIS M 8212 准确测定,其中铁矿石消化溶液中的铁离子在氧化还原滴定之前被还原为二价。在铁还原过程中,除铁(II)外,分解溶液中还原性化学物质在与钛(III)还原后不得残留。然而,有关分解溶液中存在的化学物质的氧化还原反应目前尚未完全阐明。本文在氮气环境下,通过电位法和分光光度法研究了 JIS M 8212 中铁还原过程中分解溶液中发生的氧化还原反应。锡(II)/(IV)的氧化还原反应非常缓慢,对确定铁还原指示剂的终点有很大影响。铜的氯络合物被钛(III)还原时的电位高于用作氧化还原指示剂的靛胭脂红的电位,因此还原的铜(I)给重铬酸钾滴定带来了正误差。五价钒被钛(III)还原后与钛形成络合物,也会对重铬酸钾滴定产生正干扰。为了避免这些干扰,在氮气环境下,在加入氯化锡(II)后,按比例将氯化钛(III)加入反应混合物中,以便在接下来的氧化还原滴定之前只将铁还原成二价。将拟议方案与重铬酸钾滴定法相结合,可成功测定铁矿石认证参考材料中的铁含量。
期刊介绍:
The journal provides an international medium for the publication of fundamental and technological aspects of the properties, structure, characterization and modeling, processing, fabrication, and environmental issues of iron and steel, along with related engineering materials.