{"title":"Ultrasonographic measurement of diaphragm muscle activity for assessment of respiratory function in horses","authors":"B.E. Oliveira, P.A. Canola","doi":"10.1016/j.jevs.2024.105100","DOIUrl":null,"url":null,"abstract":"<div><p>Ultrasonographic imaging of the diaphragm is a non-invasive alternative for respiratory function evaluation in horses. This study aimed to measure diaphragm thickness, thickening (change in thickness with contraction) and thickening fraction in healthy adult horses during tidal breathing and forced vital capacity. Correlation between body weight (≤400 kg and >400 kg) and diaphragm thickness was investigated. To that purpose, 20 adult horses, weight 409±50 kg, height 1.47±0.05 m, and age 16±6 years were included in the study. Diaphragm thickness was measured at end-inspiration and end-expiration using B-mode and M-mode. The transducer was placed in the 10th, 11th and 12th intercostal spaces of both hemithoraces. Measurements obtained at end inspiration using M-mode during forced vital capacity were greater than for tidal breathing for diaphragm thickness (<em>P</em>=0.006), diaphragm thickening (<em>P</em><0.001) and thickening fraction (<em>P</em><0.001). The same was found for thickening (<em>P</em><0.001) and thickening fraction (<em>P</em><0.001). Diaphragm thickness at end-inspiration was greater in horses weighing >400kg than those ≤400kg at the inspiration (0.93±0.2 cm and 0.74±0 0.02 cm, <em>P</em><0.001) and at the end of expiration (0.77±0.02 cm and 0.63±0, 02 cm, <em>P</em><0.001). There was no difference in thickening fraction between horses weighing ≤400kg and >400kg (tidal breathing: 18±2 % and 16±2 %, <em>P</em>=0.609; forced vital capacity: 39±6 % and 31±5 %, <em>P</em>=0.301). Diaphragm assessment in horses is possible using both B-mode and M-mode. Breathing workload has a positive correlation between breathing workload and diaphragm contraction. Due to the relationship demonstrated between diaphragm thickness and weight, it is recommended that diaphragm thickening fraction is used to compare diaphragm measurements between horses.</p></div>","PeriodicalId":15798,"journal":{"name":"Journal of Equine Veterinary Science","volume":"138 ","pages":"Article 105100"},"PeriodicalIF":1.3000,"publicationDate":"2024-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Equine Veterinary Science","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0737080624001060","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Ultrasonographic imaging of the diaphragm is a non-invasive alternative for respiratory function evaluation in horses. This study aimed to measure diaphragm thickness, thickening (change in thickness with contraction) and thickening fraction in healthy adult horses during tidal breathing and forced vital capacity. Correlation between body weight (≤400 kg and >400 kg) and diaphragm thickness was investigated. To that purpose, 20 adult horses, weight 409±50 kg, height 1.47±0.05 m, and age 16±6 years were included in the study. Diaphragm thickness was measured at end-inspiration and end-expiration using B-mode and M-mode. The transducer was placed in the 10th, 11th and 12th intercostal spaces of both hemithoraces. Measurements obtained at end inspiration using M-mode during forced vital capacity were greater than for tidal breathing for diaphragm thickness (P=0.006), diaphragm thickening (P<0.001) and thickening fraction (P<0.001). The same was found for thickening (P<0.001) and thickening fraction (P<0.001). Diaphragm thickness at end-inspiration was greater in horses weighing >400kg than those ≤400kg at the inspiration (0.93±0.2 cm and 0.74±0 0.02 cm, P<0.001) and at the end of expiration (0.77±0.02 cm and 0.63±0, 02 cm, P<0.001). There was no difference in thickening fraction between horses weighing ≤400kg and >400kg (tidal breathing: 18±2 % and 16±2 %, P=0.609; forced vital capacity: 39±6 % and 31±5 %, P=0.301). Diaphragm assessment in horses is possible using both B-mode and M-mode. Breathing workload has a positive correlation between breathing workload and diaphragm contraction. Due to the relationship demonstrated between diaphragm thickness and weight, it is recommended that diaphragm thickening fraction is used to compare diaphragm measurements between horses.
期刊介绍:
Journal of Equine Veterinary Science (JEVS) is an international publication designed for the practicing equine veterinarian, equine researcher, and other equine health care specialist. Published monthly, each issue of JEVS includes original research, reviews, case reports, short communications, and clinical techniques from leaders in the equine veterinary field, covering such topics as laminitis, reproduction, infectious disease, parasitology, behavior, podology, internal medicine, surgery and nutrition.