RETRACTION: Histological and histomorphometric evaluation of immediate implant placement on a dog model with a new implant surface treatment

IF 4.8 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Implants Research Pub Date : 2024-05-21 DOI:10.1111/clr.14279
{"title":"RETRACTION: Histological and histomorphometric evaluation of immediate implant placement on a dog model with a new implant surface treatment","authors":"","doi":"10.1111/clr.14279","DOIUrl":null,"url":null,"abstract":"<p>RETRACTION: J. L. Calvo-Guirado, A. J. Ortiz-Ruiz, B. Negri, L. López-Marí, C. Rodriguez-Barba, F. Schlottig, “Histological and histomorphometric evaluation of immediate implant placement on a dog model with a new implant surface treatment”, <i>Clinical Oral Implants Research</i> 21, no. 3 (2010): 308–315, https://doi.org/10.1111/j.1600-0501.2009.01841.x</p><p>The above article, published online on 9 February 2010 in Wiley Online Library (wileyonlinelibrary.com), has been retracted by agreement between the journal's Editor in Chief, Lisa J. A. Heitz-Mayfield; and John Wiley &amp; Sons Ltd.</p><p>The retraction has been agreed due to concerns raised by third parties on the data presented in the article. Several flaws and inconsistencies between results presented and experimental methods described were found. Specifically, Figure 5b is described as control group, but it used in Figure 6b to represent the test group. Figure 7c is described as control group, but it used in Figure 8a to represent the test group. Accordingly, the editors consider the findings of this article unreliable and the conclusions to be invalid. The authors have been informed of the decision to retract the article. The corresponding author J. L. Calvo-Guirado disagrees with the decision of retraction. Co-authors A. J. Ortiz-Ruiz and F. Schlottig state that they were unaware of these issues and concur with the decision for retraction based on the presented findings. The remaining co-authors were not available for a final confirmation of the retraction.</p>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":null,"pages":null},"PeriodicalIF":4.8000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14279","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.14279","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

RETRACTION: J. L. Calvo-Guirado, A. J. Ortiz-Ruiz, B. Negri, L. López-Marí, C. Rodriguez-Barba, F. Schlottig, “Histological and histomorphometric evaluation of immediate implant placement on a dog model with a new implant surface treatment”, Clinical Oral Implants Research 21, no. 3 (2010): 308–315, https://doi.org/10.1111/j.1600-0501.2009.01841.x

The above article, published online on 9 February 2010 in Wiley Online Library (wileyonlinelibrary.com), has been retracted by agreement between the journal's Editor in Chief, Lisa J. A. Heitz-Mayfield; and John Wiley & Sons Ltd.

The retraction has been agreed due to concerns raised by third parties on the data presented in the article. Several flaws and inconsistencies between results presented and experimental methods described were found. Specifically, Figure 5b is described as control group, but it used in Figure 6b to represent the test group. Figure 7c is described as control group, but it used in Figure 8a to represent the test group. Accordingly, the editors consider the findings of this article unreliable and the conclusions to be invalid. The authors have been informed of the decision to retract the article. The corresponding author J. L. Calvo-Guirado disagrees with the decision of retraction. Co-authors A. J. Ortiz-Ruiz and F. Schlottig state that they were unaware of these issues and concur with the decision for retraction based on the presented findings. The remaining co-authors were not available for a final confirmation of the retraction.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
回放:采用新型种植体表面处理方法对狗模型即刻植入种植体进行组织学和组织形态计量学评估。
Retraction:J.L.Calvo-Guirado、A.J.Ortiz-Ruiz、B.Negri、L.López-Marí、C.Rodriguez-Barba、F.Schlottig,"采用新型种植体表面处理方法在狗模型上即刻植入种植体的组织学和组织形态计量学评估",《临床口腔种植研究》21,no.3 (2010):308-315, https://doi.org/10.1111/j.1600-0501.2009.01841.x 上述文章于 2010 年 2 月 9 日在线发表于 Wiley Online Library (wileyonlinelibrary.com),经该杂志主编 Lisa J. A. Heitz-Mayfield 和 John Wiley & Sons Ltd. 协商,该文章已被撤回。同意撤稿的原因是第三方对文章中提供的数据表示担忧。我们发现文章中介绍的结果与实验方法之间存在若干缺陷和不一致之处。具体来说,图 5b 被描述为对照组,但在图 6b 中却用来代表测试组。图 7c 被描述为对照组,但在图 8a 中却用来代表试验组。因此,编辑认为本文的研究结果不可靠,结论无效。已将撤稿决定通知作者。通讯作者 J. L. Calvo-Guirado 不同意撤稿决定。共同作者A. J. Ortiz-Ruiz和F. Schlottig表示,他们不知道这些问题,并同意根据所提交的研究结果撤稿的决定。其余合著者无法对撤稿做出最终确认。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Oral Implants Research
Clinical Oral Implants Research 医学-工程:生物医学
CiteScore
7.70
自引率
11.60%
发文量
149
审稿时长
3 months
期刊介绍: Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.
期刊最新文献
Does an untreated peri-implant dehiscence defect affect the progression of peri-implantitis?: A preclinical in vivo experimental study. Early implant placement versus ridge preservation and delayed implant placement: Analysis of profilometric, clinician- and patient-reported outcomes from a two-centre RCT. Low-dose, standard, and high-resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens. Factors affecting radiographic marginal bone resorption at dental implants in function for at least 5 years: A multicenter retrospective study. A cross-sectional CBCT assessment of the relative position of one-piece titanium-zirconium mini-implants placed for mandibular overdentures using non-guided surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1