{"title":"Lower extremity woven and nonwoven venous stent morphology and luminal changes","authors":"","doi":"10.1016/j.jvsv.2024.101893","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>Venous stents are a common treatment modality for obstructive venous disease. Venous stents differentiate themselves by either a woven or braided structure, open or closed cell arrangement or based on material composition (elgiloy vs nitinol). Changes in the morphology of venous stents over time may contribute to restenosis or thrombosis. Woven elgiloy stents are prone to proximal and distal edge deformation compared with dedicated venous stents, which offer increased radial force at stent edges. The objective of this study is to describe luminal morphological changes among various venous stents and between woven to nonwoven venous stent configuration, over time.</div></div><div><h3>Methods</h3><div>A retrospective review at a single institution between January 2014 and June 2021 identified patients treated with venous stents. Patients with iliac and/or femoral venous stents with intraoperative intravascular ultrasound and a postoperative computed tomography scan were included in the study. Cross-sectional diameters measurements were taken at proximal, middle, and distal portions of each stent from intravascular ultrasound examination at the time of initial stenting and compared with the cross-sectional diameter measurements taken from computed tomography imaging at follow-up. A paired <em>t</em> test was used to compare the luminal change with a D'Agostino-Pearson test used for normality.</div></div><div><h3>Results</h3><div>Fifty-four stents distributed among 38 patients were identified. The mean time to follow-up was 17.5 months. Stents were placed in the common iliac vein (n = 37, 68.5%), external iliac vein (n = 14, 25.9%), and common femoral vein (n = 3, 5.6%). Implanted stents included the Boston Scientific Wallstent (n = 23, 42.6%), Bard Venovo (n = 3, 5.6%), Boston Scientific Vici (n = 23, 42.6%), and Medtronic Abre (n = 5, 9.3%). The mean luminal loss was measured at 2.12 mm proximally (95% confidence interval [CI], 1.64-2.60; <em>P</em><.001), 1.29 mm at the mid-stent (95% CI, 0.83-1.74, <em>P</em><.001), and 1.56 mm distally (95% CI, 0.99-2.12; <em>P</em><.001). There was no significant difference in luminal changes between woven and nonwoven stents at proximal (<em>P</em> = .374), middle (<em>P</em> = .179), and distal (<em>P</em> = .609) stent measurements.</div></div><div><h3>Conclusions</h3><div>This study reports morphological changes within venous stents and between woven and nonwoven venous stents. Our findings demonstrate that the edge-stent luminal decrease traditionally attributed to woven configurations also occurs with the newer nonwoven stents. Additional factors such as anatomical location, pelvic curvature, and other external forces may be accountable for this change rather than geometrical configuration of the stent.</div></div>","PeriodicalId":17537,"journal":{"name":"Journal of vascular surgery. Venous and lymphatic disorders","volume":"12 6","pages":"Article 101893"},"PeriodicalIF":2.8000,"publicationDate":"2024-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of vascular surgery. Venous and lymphatic disorders","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213333X24002099","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
Venous stents are a common treatment modality for obstructive venous disease. Venous stents differentiate themselves by either a woven or braided structure, open or closed cell arrangement or based on material composition (elgiloy vs nitinol). Changes in the morphology of venous stents over time may contribute to restenosis or thrombosis. Woven elgiloy stents are prone to proximal and distal edge deformation compared with dedicated venous stents, which offer increased radial force at stent edges. The objective of this study is to describe luminal morphological changes among various venous stents and between woven to nonwoven venous stent configuration, over time.
Methods
A retrospective review at a single institution between January 2014 and June 2021 identified patients treated with venous stents. Patients with iliac and/or femoral venous stents with intraoperative intravascular ultrasound and a postoperative computed tomography scan were included in the study. Cross-sectional diameters measurements were taken at proximal, middle, and distal portions of each stent from intravascular ultrasound examination at the time of initial stenting and compared with the cross-sectional diameter measurements taken from computed tomography imaging at follow-up. A paired t test was used to compare the luminal change with a D'Agostino-Pearson test used for normality.
Results
Fifty-four stents distributed among 38 patients were identified. The mean time to follow-up was 17.5 months. Stents were placed in the common iliac vein (n = 37, 68.5%), external iliac vein (n = 14, 25.9%), and common femoral vein (n = 3, 5.6%). Implanted stents included the Boston Scientific Wallstent (n = 23, 42.6%), Bard Venovo (n = 3, 5.6%), Boston Scientific Vici (n = 23, 42.6%), and Medtronic Abre (n = 5, 9.3%). The mean luminal loss was measured at 2.12 mm proximally (95% confidence interval [CI], 1.64-2.60; P<.001), 1.29 mm at the mid-stent (95% CI, 0.83-1.74, P<.001), and 1.56 mm distally (95% CI, 0.99-2.12; P<.001). There was no significant difference in luminal changes between woven and nonwoven stents at proximal (P = .374), middle (P = .179), and distal (P = .609) stent measurements.
Conclusions
This study reports morphological changes within venous stents and between woven and nonwoven venous stents. Our findings demonstrate that the edge-stent luminal decrease traditionally attributed to woven configurations also occurs with the newer nonwoven stents. Additional factors such as anatomical location, pelvic curvature, and other external forces may be accountable for this change rather than geometrical configuration of the stent.
期刊介绍:
Journal of Vascular Surgery: Venous and Lymphatic Disorders is one of a series of specialist journals launched by the Journal of Vascular Surgery. It aims to be the premier international Journal of medical, endovascular and surgical management of venous and lymphatic disorders. It publishes high quality clinical, research, case reports, techniques, and practice manuscripts related to all aspects of venous and lymphatic disorders, including malformations and wound care, with an emphasis on the practicing clinician. The journal seeks to provide novel and timely information to vascular surgeons, interventionalists, phlebologists, wound care specialists, and allied health professionals who treat patients presenting with vascular and lymphatic disorders. As the official publication of The Society for Vascular Surgery and the American Venous Forum, the Journal will publish, after peer review, selected papers presented at the annual meeting of these organizations and affiliated vascular societies, as well as original articles from members and non-members.