{"title":"Detection and Defense Method Against False Data Injection Attacks for Distributed Load Frequency Control System in Microgrid","authors":"Zhixun Zhang;Jianqiang Hu;Jianquan Lu;Jie Yu;Jinde Cao;Ardak Kashkynbayev","doi":"10.35833/MPCE.2023.000400","DOIUrl":null,"url":null,"abstract":"In the realm of microgrid (MG), the distributed load frequency control (LFC) system has proven to be highly susceptible to the negative effects of false data injection attacks (FDIAs). Considering the significant responsibility of the distributed LFC system for maintaining frequency stability within the MG, this paper proposes a detection and defense method against unobservable FDIAs in the distributed LFC system. Firstly, the method integrates a bi-directional long short-term memory (BiLSTM) neural network and an improved whale optimization algorithm (IWOA) into the LFC controller to detect and counteract FDIAs. Secondly, to enable the BiLSTM neural network to proficiently detect multiple types of FDIAs with utmost precision, the model employs a historical MG dataset comprising the frequency and power variances. Finally, the IWOA is utilized to optimize the proportional-integral-derivative (PID) controller parameters to counteract the negative impacts of FDIAs. The proposed detection and defense method is validated by building the distributed LFC system in Simulink.","PeriodicalId":51326,"journal":{"name":"Journal of Modern Power Systems and Clean Energy","volume":"12 3","pages":"913-924"},"PeriodicalIF":5.7000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10316540","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Modern Power Systems and Clean Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10316540/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
In the realm of microgrid (MG), the distributed load frequency control (LFC) system has proven to be highly susceptible to the negative effects of false data injection attacks (FDIAs). Considering the significant responsibility of the distributed LFC system for maintaining frequency stability within the MG, this paper proposes a detection and defense method against unobservable FDIAs in the distributed LFC system. Firstly, the method integrates a bi-directional long short-term memory (BiLSTM) neural network and an improved whale optimization algorithm (IWOA) into the LFC controller to detect and counteract FDIAs. Secondly, to enable the BiLSTM neural network to proficiently detect multiple types of FDIAs with utmost precision, the model employs a historical MG dataset comprising the frequency and power variances. Finally, the IWOA is utilized to optimize the proportional-integral-derivative (PID) controller parameters to counteract the negative impacts of FDIAs. The proposed detection and defense method is validated by building the distributed LFC system in Simulink.
期刊介绍:
Journal of Modern Power Systems and Clean Energy (MPCE), commencing from June, 2013, is a newly established, peer-reviewed and quarterly published journal in English. It is the first international power engineering journal originated in mainland China. MPCE publishes original papers, short letters and review articles in the field of modern power systems with focus on smart grid technology and renewable energy integration, etc.