Stress-Strain State of Steel Fiber-Reinforced Concrete under Compression Taking into Account Unloading from Inelastic Region

V.P. Agapov, A. Markovich, Prashanta Dkhar, Darya A. Golishevskaia
{"title":"Stress-Strain State of Steel Fiber-Reinforced Concrete under Compression Taking into Account Unloading from Inelastic Region","authors":"V.P. Agapov, A. Markovich, Prashanta Dkhar, Darya A. Golishevskaia","doi":"10.22363/1815-5235-2024-20-2-170-181","DOIUrl":null,"url":null,"abstract":"The purpose of the study is to examine the physical and mechanical characteristics of steel fiber-reinforced concrete under compression, including: modulus of elasticity, Poisson ratio, values of ultimate strains under compression, values of compressive strength with different percentages of dispersed reinforcement. An experimental investigation program, which included the production of cube samples measuring 100×100×100 mm, as well as a compression test under static loading, taking into account unloading from the region of inelastic deformations, was developed and carried out. Two types of steel fiber were chosen as dispersed reinforcement: hooked end and wave shape. The volume content of steel fiber in the cube samples was 0.5, 1.0, 1.5 and 2.0 %. As a result of the investigation, the strength and deformation characteristics of steel fiber reinforced concrete under compression were obtained. Based on the experimental data, actual strain diagrams of steel fiber reinforced concrete were constructed, taking into account the type of reinforcing fibers and the percentage of reinforcing fiber. Based on the obtained diagrams, a law of deformation of steel fiber reinforced concrete is proposed, which can be described by a polynomial function of the fourth order with constant coefficients that determine the shape of the stress-strain curve. The presented research results can be used in developing a methodology for physically nonlinear analysis of steel fiber reinforced concrete elements with a percentage of dispersed reinforcement from 0.5 to 2.0 %.","PeriodicalId":32610,"journal":{"name":"Structural Mechanics of Engineering Constructions and Buildings","volume":" January","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Mechanics of Engineering Constructions and Buildings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22363/1815-5235-2024-20-2-170-181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of the study is to examine the physical and mechanical characteristics of steel fiber-reinforced concrete under compression, including: modulus of elasticity, Poisson ratio, values of ultimate strains under compression, values of compressive strength with different percentages of dispersed reinforcement. An experimental investigation program, which included the production of cube samples measuring 100×100×100 mm, as well as a compression test under static loading, taking into account unloading from the region of inelastic deformations, was developed and carried out. Two types of steel fiber were chosen as dispersed reinforcement: hooked end and wave shape. The volume content of steel fiber in the cube samples was 0.5, 1.0, 1.5 and 2.0 %. As a result of the investigation, the strength and deformation characteristics of steel fiber reinforced concrete under compression were obtained. Based on the experimental data, actual strain diagrams of steel fiber reinforced concrete were constructed, taking into account the type of reinforcing fibers and the percentage of reinforcing fiber. Based on the obtained diagrams, a law of deformation of steel fiber reinforced concrete is proposed, which can be described by a polynomial function of the fourth order with constant coefficients that determine the shape of the stress-strain curve. The presented research results can be used in developing a methodology for physically nonlinear analysis of steel fiber reinforced concrete elements with a percentage of dispersed reinforcement from 0.5 to 2.0 %.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑到非弹性区域卸载的钢纤维加固混凝土压缩下的应力-应变状态
研究的目的是检验钢纤维加固混凝土在压缩条件下的物理和机械特性,包括:弹性模量、泊松比、压缩极限应变值、不同分散钢筋百分比的抗压强度值。制定并实施了一项实验研究计划,包括制作 100×100×100 毫米的立方体样品,以及在静态加载条件下进行压缩试验,同时考虑到从非弹性变形区域卸载的情况。选择了两种类型的钢纤维作为分散加固材料:钩形端部和波形。立方体样品中钢纤维的体积含量分别为 0.5%、1.0%、1.5% 和 2.0%。研究结果表明,钢纤维加固混凝土在压缩条件下的强度和变形特性。根据实验数据,并考虑到钢筋纤维的类型和百分比,构建了钢筋混凝土的实际应变图。根据所获得的图表,提出了钢纤维加固混凝土的变形规律,该规律可以用一个四阶多项式函数来描述,其常数系数决定了应力-应变曲线的形状。本文介绍的研究成果可用于制定钢纤维加固混凝土构件的物理非线性分析方法,分散钢筋的百分比为 0.5% 至 2.0%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
26
审稿时长
18 weeks
期刊最新文献
Optimal Duration of Observations During Seismic Inspection of Buildings Effect of Sinusoidal Fiber Waviness on Non-Linear Dynamic Performance of Laminated Composite Plates with Variable Fiber Spacing Deformation of Cylindrical Shell Made of 9X2 Steel Under Complex Loading Parameterization of Maxwell - Cremona Diagram for Determining Forces in Elements of a Scissors Truss Geometric Investigation of Three Thin Shells with Ruled Middle Surfaces with the Same Main Frame
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1