Jacopo Pelini , Stefano Dello Russo , Inaki Lopez Garcia , Maria Concetta Canino , Alberto Roncaglia , Pablo Cancio Pastor , Iacopo Galli , Wei Ren , Paolo De Natale , Zhen Wang , Simone Borri , Mario Siciliani de Cumis
{"title":"New silicon-based micro-electro-mechanical systems for photo-acoustic trace-gas detection","authors":"Jacopo Pelini , Stefano Dello Russo , Inaki Lopez Garcia , Maria Concetta Canino , Alberto Roncaglia , Pablo Cancio Pastor , Iacopo Galli , Wei Ren , Paolo De Natale , Zhen Wang , Simone Borri , Mario Siciliani de Cumis","doi":"10.1016/j.pacs.2024.100619","DOIUrl":null,"url":null,"abstract":"<div><p>The achievable sensitivity level of photo-acoustic trace-gas sensors essentially depends on the performances of the acoustic transducer. In this work, the mechanical response of different silicon-based micro-electro-mechanical systems (MEMS) is characterized, aiming at investigating both their mechanical properties, namely the resonance frequency and the quality factor, and the minimum detection limit (MDL) achievable when they are exploited as an acoustic-to-voltage transducer in a trace-gas photoacoustic setup. For this purpose, a 4.56<!--> <!-->µm Continuous-Wave (CW) quantum cascade laser (QCL) is used to excite a strong N<sub>2</sub>O roto-vibrational transition with a line strength of 2.14 × 10<sup>−19</sup> cm/molecule, and the detection of MEMS oscillations is performed via an interferometric readout. As a general trend, the minimum detection limit decreases when the resonance frequency investigated increases, achieving a value of 15 parts per billion with a 3 dB cut-off lock-in bandwidth equal to 100 mHz, around 10 kHz.</p></div>","PeriodicalId":56025,"journal":{"name":"Photoacoustics","volume":"38 ","pages":"Article 100619"},"PeriodicalIF":7.1000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2213597924000363/pdfft?md5=f2c854d090400b3ebe07a9d4c8ffdc34&pid=1-s2.0-S2213597924000363-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photoacoustics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213597924000363","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The achievable sensitivity level of photo-acoustic trace-gas sensors essentially depends on the performances of the acoustic transducer. In this work, the mechanical response of different silicon-based micro-electro-mechanical systems (MEMS) is characterized, aiming at investigating both their mechanical properties, namely the resonance frequency and the quality factor, and the minimum detection limit (MDL) achievable when they are exploited as an acoustic-to-voltage transducer in a trace-gas photoacoustic setup. For this purpose, a 4.56 µm Continuous-Wave (CW) quantum cascade laser (QCL) is used to excite a strong N2O roto-vibrational transition with a line strength of 2.14 × 10−19 cm/molecule, and the detection of MEMS oscillations is performed via an interferometric readout. As a general trend, the minimum detection limit decreases when the resonance frequency investigated increases, achieving a value of 15 parts per billion with a 3 dB cut-off lock-in bandwidth equal to 100 mHz, around 10 kHz.
PhotoacousticsPhysics and Astronomy-Atomic and Molecular Physics, and Optics
CiteScore
11.40
自引率
16.50%
发文量
96
审稿时长
53 days
期刊介绍:
The open access Photoacoustics journal (PACS) aims to publish original research and review contributions in the field of photoacoustics-optoacoustics-thermoacoustics. This field utilizes acoustical and ultrasonic phenomena excited by electromagnetic radiation for the detection, visualization, and characterization of various materials and biological tissues, including living organisms.
Recent advancements in laser technologies, ultrasound detection approaches, inverse theory, and fast reconstruction algorithms have greatly supported the rapid progress in this field. The unique contrast provided by molecular absorption in photoacoustic-optoacoustic-thermoacoustic methods has allowed for addressing unmet biological and medical needs such as pre-clinical research, clinical imaging of vasculature, tissue and disease physiology, drug efficacy, surgery guidance, and therapy monitoring.
Applications of this field encompass a wide range of medical imaging and sensing applications, including cancer, vascular diseases, brain neurophysiology, ophthalmology, and diabetes. Moreover, photoacoustics-optoacoustics-thermoacoustics is a multidisciplinary field, with contributions from chemistry and nanotechnology, where novel materials such as biodegradable nanoparticles, organic dyes, targeted agents, theranostic probes, and genetically expressed markers are being actively developed.
These advanced materials have significantly improved the signal-to-noise ratio and tissue contrast in photoacoustic methods.