Comparison of the Time-Course and Magnitude of Cardiorespiratory Responses to Superimposed Surgical Masks or N95 Respirators during 20-min Treadmill Walking

IF 8.3 2区 材料科学 Q1 MATERIALS SCIENCE, MULTIDISCIPLINARY ACS Applied Materials & Interfaces Pub Date : 2024-05-01 DOI:10.1152/physiol.2024.39.s1.1717
Angela Galeos, Rodion Isakovich, Valerie C Cates, Anthony Marullo, Nicholas Strzalkowski, Trevor Day
{"title":"Comparison of the Time-Course and Magnitude of Cardiorespiratory Responses to Superimposed Surgical Masks or N95 Respirators during 20-min Treadmill Walking","authors":"Angela Galeos, Rodion Isakovich, Valerie C Cates, Anthony Marullo, Nicholas Strzalkowski, Trevor Day","doi":"10.1152/physiol.2024.39.s1.1717","DOIUrl":null,"url":null,"abstract":"Wearing medical barriers has recently expanded from healthcare to public settings, and could increase dead space and facilitate rebreathing of expired air resulting in heat accumulation, hypercapnia, and hypoxia, particularly during physical activity. We recently showed that participants wearing surgical masks (SM) and N95 respirators (N95) over 60-min during seated rest had mild and immediately reversible (a) increases face microclimate temperature, (b) increases in the pressure of end-tidal (PET)CO2, (c) decreases in PETO2, but (d) no differences in peripheral oxygen saturation (SpO2). Previous publications showed conflicting results of superimposed barrier wearing during physical activity, and there are limited studies that assessed face microclimate temperature and end-tidal gases, particularly comparing superimposed SM and N95. We hypothesized that participants wearing SM and N95 will experience mild face microclimate hyperthermia, hypoxia, and hypercapnia during 3mph treadmill walking. Participants (n=18; 8F) randomly wore (a) no barrier (NB), (b) SM or (c) N95 during a 10-min standing baseline, 20-min treadmill walking (3 mph), and a 10-min standing recovery. We continuously measured face microclimate temperature (thermistor), end tidal gases (PETCO2, PETO2; oro-nasal cannula), SpO2 (peripheral pulse oximeter). Average 20-min PETCO2 (higher; p<0.0001, P=0.0001) and PETO2 (lower; P=0.0003, P=0.0178) were significantly from baseline for both SM and N95, respectively. The delta between the 20-min average compared to the baseline data was not statistically significant for PETCO2 or PETO2 in all three conditions, except for ΔPETCO2 NB vs. N95 (higher; P=0.0344). Additionally, there was no difference in SpO2 across all barrier conditions during exercise. These mild physiological effects may account for qualitative reports of shortness of breath and increased perceived exertion while wearing barriers during physical activity. However, these effect-magnitudes are not physiologically-meaningful, and are immediately reversed upon cessation of exercise and/or barrier removal. NSERC. This is the full abstract presented at the American Physiology Summit 2024 meeting and is only available in HTML format. There are no additional versions or additional content available for this abstract. Physiology was not involved in the peer review process.","PeriodicalId":5,"journal":{"name":"ACS Applied Materials & Interfaces","volume":"33 2","pages":""},"PeriodicalIF":8.3000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Materials & Interfaces","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1152/physiol.2024.39.s1.1717","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Wearing medical barriers has recently expanded from healthcare to public settings, and could increase dead space and facilitate rebreathing of expired air resulting in heat accumulation, hypercapnia, and hypoxia, particularly during physical activity. We recently showed that participants wearing surgical masks (SM) and N95 respirators (N95) over 60-min during seated rest had mild and immediately reversible (a) increases face microclimate temperature, (b) increases in the pressure of end-tidal (PET)CO2, (c) decreases in PETO2, but (d) no differences in peripheral oxygen saturation (SpO2). Previous publications showed conflicting results of superimposed barrier wearing during physical activity, and there are limited studies that assessed face microclimate temperature and end-tidal gases, particularly comparing superimposed SM and N95. We hypothesized that participants wearing SM and N95 will experience mild face microclimate hyperthermia, hypoxia, and hypercapnia during 3mph treadmill walking. Participants (n=18; 8F) randomly wore (a) no barrier (NB), (b) SM or (c) N95 during a 10-min standing baseline, 20-min treadmill walking (3 mph), and a 10-min standing recovery. We continuously measured face microclimate temperature (thermistor), end tidal gases (PETCO2, PETO2; oro-nasal cannula), SpO2 (peripheral pulse oximeter). Average 20-min PETCO2 (higher; p<0.0001, P=0.0001) and PETO2 (lower; P=0.0003, P=0.0178) were significantly from baseline for both SM and N95, respectively. The delta between the 20-min average compared to the baseline data was not statistically significant for PETCO2 or PETO2 in all three conditions, except for ΔPETCO2 NB vs. N95 (higher; P=0.0344). Additionally, there was no difference in SpO2 across all barrier conditions during exercise. These mild physiological effects may account for qualitative reports of shortness of breath and increased perceived exertion while wearing barriers during physical activity. However, these effect-magnitudes are not physiologically-meaningful, and are immediately reversed upon cessation of exercise and/or barrier removal. NSERC. This is the full abstract presented at the American Physiology Summit 2024 meeting and is only available in HTML format. There are no additional versions or additional content available for this abstract. Physiology was not involved in the peer review process.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在 20 分钟跑步机行走过程中,比较叠加手术面罩或 N95 呼吸器的心肺反应时间过程和幅度
佩戴医疗屏障最近已从医疗机构扩展到公共场所,可能会增加死腔,促进呼出气体的再吸入,导致热量积聚、高碳酸血症和缺氧,尤其是在体育活动期间。我们最近的研究表明,在坐着休息时佩戴外科口罩(SM)和 N95 呼吸器(N95)超过 60 分钟的参与者会出现轻微且可立即逆转的以下情况:(a) 面部微气候温度升高;(b) 潮气末二氧化碳(PET)压力升高;(c) PETO2 降低;但 (d) 周围血氧饱和度(SpO2)无差异。以前的出版物显示,在体育活动中佩戴叠加屏障的结果相互矛盾,评估面部微气候温度和潮气末气体的研究有限,特别是比较叠加 SM 和 N95 的研究。我们假设,佩戴 SM 和 N95 的参与者在每小时 3 英里的跑步机行走过程中会出现轻微的面部微气候高热、缺氧和高碳酸血症。参与者(n=18;8F)在 10 分钟站立基线、20 分钟跑步机行走(3 英里/小时)和 10 分钟站立恢复期间随机佩戴(a)无屏障(NB)、(b)SM 或(c)N95。我们连续测量面部微气候温度(温度计)、潮气末(PETCO2、PETO2;口鼻插管)、SpO2(外周脉搏血氧计)。20 分钟平均 PETCO2(较高;P<0.0001,P=0.0001)和 PETO2(较低;P=0.0003,P=0.0178)分别与 SM 和 N95 的基线相比有显著差异。除 ΔPETCO2 NB 与 N95(较高;P=0.0344)外,在所有三种情况下,20 分钟平均值与基线数据相比,PETCO2 或 PETO2 的三角差均无统计学意义。此外,在运动过程中,所有屏障条件下的 SpO2 均无差异。这些轻微的生理影响可能是在体育活动中佩戴屏障时出现呼吸急促和体力消耗增加的定性报告的原因。不过,这些影响的程度在生理上没有意义,而且在停止运动和/或移除屏障后会立即逆转。国家科学研究中心。这是在 2024 年美国生理学峰会上发表的摘要全文,仅以 HTML 格式提供。本摘要没有附加版本或附加内容。生理学》未参与同行评审过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Materials & Interfaces
ACS Applied Materials & Interfaces 工程技术-材料科学:综合
CiteScore
16.00
自引率
6.30%
发文量
4978
审稿时长
1.8 months
期刊介绍: ACS Applied Materials & Interfaces is a leading interdisciplinary journal that brings together chemists, engineers, physicists, and biologists to explore the development and utilization of newly-discovered materials and interfacial processes for specific applications. Our journal has experienced remarkable growth since its establishment in 2009, both in terms of the number of articles published and the impact of the research showcased. We are proud to foster a truly global community, with the majority of published articles originating from outside the United States, reflecting the rapid growth of applied research worldwide.
期刊最新文献
Hot Electron Photoemission from Tunable Electron Affinity Semiconductor Cathodes Ferroelectric Tunable Nonvolatile Polarization Detection Based on 2H α-In2Se3 Fluoride Ion Passivation of CsPbBr3 Nanocrystals at Room Temperature for Highly Efficient and Stable White Light-Emitting Diodes Butylammonium-Based Chiral 2D Perovskite Single Crystals for Efficient UV Circularly Polarized Light Differentiation and High-Performance X-ray Detection Issue Editorial Masthead
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1