Investigation of the relationship between colonoscopy insertion difficulty factors and endoscope shape using an endoscopic position detection unit.

IF 2 4区 医学 Q3 NUTRITION & DIETETICS Journal of Clinical Biochemistry and Nutrition Pub Date : 2024-05-01 Epub Date: 2023-12-15 DOI:10.3164/jcbn.23-109
Takashi Kawai, Yusuke Kawai, Yoshika Akimito, Mariko Hamada, Eri Iwata, Ryota Niikura, Naoyoshi Nagata, Mitsushige Sugimoto, Kyosuke Yanagisawa, Masakatsu Fukuzawa, Takao Itoi
{"title":"Investigation of the relationship between colonoscopy insertion difficulty factors and endoscope shape using an endoscopic position detection unit.","authors":"Takashi Kawai, Yusuke Kawai, Yoshika Akimito, Mariko Hamada, Eri Iwata, Ryota Niikura, Naoyoshi Nagata, Mitsushige Sugimoto, Kyosuke Yanagisawa, Masakatsu Fukuzawa, Takao Itoi","doi":"10.3164/jcbn.23-109","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we investigated the relationship between the cecal intubation time (CIT) and the form and method used for passing through the sigmoid/descending colon junction (SDJ) and the hepatic flexure using an endoscopic position detection unit (UPD), with reference to various factors [age, sex, body mass index (BMI), history of abdominal and pelvic surgery, and diverticulum]. A total of 152 patients underwent colonoscopy with UPD. The mean age was 66.9 ± 12.4 years, and the male to female ratio was 3.6:1. The average CIT time was 14.3 ± 8.2 min. Age, number of experienced endoscopies, history of abdominal and pelvic surgery, BMI, and diverticulum were associated with prolonged CIT; SDJ passage pattern was straight: 8.6 ± 5.0, alpha loop: 11.8 ± 5.6, puzzle ring-like loop: 20.2 ± 5.0, reverse alpha loop: 22.4 ± 9.7, and other loop: 24.7 ± 10.5. The hepatic flexure passing method was in the following order: right rotation maneuver: 12.6 ± 6.6, push maneuver: 15.1 ± 5.9, and right rotation with positional change maneuver: 20.5 ± 7.2. In conclusion, colonoscopy with UPD revealed an association between CIT and SDJ passage pattern and hepatic flexure passing method.</p>","PeriodicalId":15429,"journal":{"name":"Journal of Clinical Biochemistry and Nutrition","volume":"74 3","pages":"245-252"},"PeriodicalIF":2.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11111465/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Biochemistry and Nutrition","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3164/jcbn.23-109","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we investigated the relationship between the cecal intubation time (CIT) and the form and method used for passing through the sigmoid/descending colon junction (SDJ) and the hepatic flexure using an endoscopic position detection unit (UPD), with reference to various factors [age, sex, body mass index (BMI), history of abdominal and pelvic surgery, and diverticulum]. A total of 152 patients underwent colonoscopy with UPD. The mean age was 66.9 ± 12.4 years, and the male to female ratio was 3.6:1. The average CIT time was 14.3 ± 8.2 min. Age, number of experienced endoscopies, history of abdominal and pelvic surgery, BMI, and diverticulum were associated with prolonged CIT; SDJ passage pattern was straight: 8.6 ± 5.0, alpha loop: 11.8 ± 5.6, puzzle ring-like loop: 20.2 ± 5.0, reverse alpha loop: 22.4 ± 9.7, and other loop: 24.7 ± 10.5. The hepatic flexure passing method was in the following order: right rotation maneuver: 12.6 ± 6.6, push maneuver: 15.1 ± 5.9, and right rotation with positional change maneuver: 20.5 ± 7.2. In conclusion, colonoscopy with UPD revealed an association between CIT and SDJ passage pattern and hepatic flexure passing method.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用内窥镜位置检测装置研究结肠镜插入难度因素与内窥镜形状之间的关系。
在这项研究中,我们研究了盲肠插管时间(CIT)与使用内镜位置检测装置(UPD)通过乙状结肠/降结肠交界处(SDJ)和肝曲的形式和方法之间的关系,并参考了各种因素[年龄、性别、体重指数(BMI)、腹部和盆腔手术史以及憩室]。共有 152 名患者接受了带有 UPD 的结肠镜检查。平均年龄为 66.9 ± 12.4 岁,男女比例为 3.6:1。平均 CIT 时间为 14.3 ± 8.2 分钟。年龄、内镜检查次数、腹部和盆腔手术史、体重指数和憩室与 CIT 时间延长有关;SDJ 通过模式为直:8.6 ± 5.0,α环:11.8 ± 5.6,α环:11.8 ± 5.6:11.8 ± 5.6,谜环状襻:20.2 ± 5.0,反向α环:22.4 ± 9.7,其他循环:24.7 ± 10.5.肝曲通过法依次为:右旋手法:12.6 ± 6.6,推压法15.1 ± 5.9,右旋转并改变位置手法:20.5 ± 7.2。总之,使用 UPD 进行结肠镜检查发现,CIT 和 SDJ 通过模式与肝曲通过方法之间存在关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.30
自引率
8.30%
发文量
57
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Biochemistry and Nutrition (JCBN) is an international, interdisciplinary publication encompassing chemical, biochemical, physiological, pathological, toxicological and medical approaches to research on lipid peroxidation, free radicals, oxidative stress and nutrition. The Journal welcomes original contributions dealing with all aspects of clinical biochemistry and clinical nutrition including both in vitro and in vivo studies.
期刊最新文献
Helicobacter pylori infection and oxidative stress. Characterized factors of subjects who were first time diagnosed as hyperglycemia more than 126 mg/dl during annual or biannual medical checkups: a case-control study in Japan. Effect of cerium oxide on iron metabolism in mice. Effect of omega-3 fatty acids on sleep: a systematic review and meta-analysis of randomized controlled trials. Effective disruption of cancer cell membranes by photodynamic therapy with cell membrane-adhesive photosensitizer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1