{"title":"[Pulsed DPOAEs in serial measurements : Combined analysis paradigm of simultaneously occurring changes in hearing thresholds and DPOAEs. German version].","authors":"Katharina Bader, Dennis Zelle, Anthony W Gummer, Ernst Dalhoff","doi":"10.1007/s00106-024-01477-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To date, there is no consensus on how to standardize the assessment of ototoxicity in serial measurements. For the diagnosis of damage to the cochlear amplifier, measurement methods are required that have the highest possible test-retest reliability and validity for detecting persistent damage. Estimated distortion-product thresholds (L<sub>EDPT</sub>) based on short-pulse distortion-product otoacoustic emission (DPOAE) level maps use individually optimal DPOAE stimulus levels and allow reliable quantitative estimation of cochlea-related hearing loss.</p><p><strong>Materials and methods: </strong>Hearing thresholds were estimated objectively using L<sub>EDPT</sub> and subjectively using modified Békésy tracking audiometry (L<sub>TA</sub>). Recordings were performed seven times within three months at 14 frequencies (f<sub>2</sub> = 1-14 kHz) in 20 ears (PTA<sub>4</sub> <sub>(0.5-4</sub> <sub>kHz)</sub> < 20 dB HL). Reconstruction of the DPOAE growth behavior as a function of the stimulus levels L<sub>1</sub>, L<sub>2</sub> was performed on the basis of 21 DPOAE amplitudes. A numerical fit of a nonlinear mathematical function to the three-dimensional DPOAE growth function yielded L<sub>EDPT</sub> for each stimulus frequency. For the combined analysis, probability distributions of hearing thresholds (L<sub>TA</sub>, L<sub>EDPT</sub>), DPOAE levels (L<sub>DP</sub>), and combinations thereof were determined.</p><p><strong>Results: </strong>L<sub>TA</sub> and L<sub>EDPT</sub> each exhibited a test-retest reliability with a median of absolute differences (AD) of 3.2 dB and 3.3 dB, respectively. Combining L<sub>EDPT</sub>, L<sub>DP</sub>, and L<sub>TA</sub> into a single parameter yielded a significantly smaller median AD of 2.0 dB.</p><p><strong>Conclusion: </strong>It is expected that an analysis paradigm based on a combination of L<sub>EDPT</sub>, suprathreshold L<sub>DP</sub>, and fine-structure-reduced L<sub>TA</sub> would achieve higher test performance (sensitivity and specificity), allowing reliable detection of pathological or regenerative changes in the outer hair cells.</p>","PeriodicalId":55052,"journal":{"name":"Hno","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11339121/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hno","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00106-024-01477-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/27 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: To date, there is no consensus on how to standardize the assessment of ototoxicity in serial measurements. For the diagnosis of damage to the cochlear amplifier, measurement methods are required that have the highest possible test-retest reliability and validity for detecting persistent damage. Estimated distortion-product thresholds (LEDPT) based on short-pulse distortion-product otoacoustic emission (DPOAE) level maps use individually optimal DPOAE stimulus levels and allow reliable quantitative estimation of cochlea-related hearing loss.
Materials and methods: Hearing thresholds were estimated objectively using LEDPT and subjectively using modified Békésy tracking audiometry (LTA). Recordings were performed seven times within three months at 14 frequencies (f2 = 1-14 kHz) in 20 ears (PTA4(0.5-4kHz) < 20 dB HL). Reconstruction of the DPOAE growth behavior as a function of the stimulus levels L1, L2 was performed on the basis of 21 DPOAE amplitudes. A numerical fit of a nonlinear mathematical function to the three-dimensional DPOAE growth function yielded LEDPT for each stimulus frequency. For the combined analysis, probability distributions of hearing thresholds (LTA, LEDPT), DPOAE levels (LDP), and combinations thereof were determined.
Results: LTA and LEDPT each exhibited a test-retest reliability with a median of absolute differences (AD) of 3.2 dB and 3.3 dB, respectively. Combining LEDPT, LDP, and LTA into a single parameter yielded a significantly smaller median AD of 2.0 dB.
Conclusion: It is expected that an analysis paradigm based on a combination of LEDPT, suprathreshold LDP, and fine-structure-reduced LTA would achieve higher test performance (sensitivity and specificity), allowing reliable detection of pathological or regenerative changes in the outer hair cells.
期刊介绍:
HNO is an internationally recognized journal and addresses all ENT specialists in practices and clinics dealing with all aspects of ENT medicine, e.g. prevention, diagnostic methods, complication management, modern therapy strategies and surgical procedures.
Review articles provide an overview on selected topics and offer the reader a summary of current findings from all fields of ENT medicine.
Freely submitted original papers allow the presentation of important clinical studies and serve the scientific exchange.
Case reports feature interesting cases and aim at optimizing diagnostic and therapeutic strategies.
Review articles under the rubric ''Continuing Medical Education'' present verified results of scientific research and their integration into daily practice.