{"title":"[Study on evaluation method of circular small shadow profusion in chest CT reconstruction images of pneumoconiosis].","authors":"C Liu, M Yang, Q Wang, J Bai, Z Duan, H T Dong","doi":"10.3760/cma.j.cn121094-20221226-00607","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To select chest CT image patterns for the diagnosis of pneumoconiosis and establish a method for determining the profusion of circular small shadows in chest CT. <b>Methods:</b> In April 2021, 66 cases of occupational pneumoconiosis patients with digital radiography (DR) chest radiographs and chest CT imaging data with circular small shadow as the main manifestations were selected as the study objects. 1.5 mm and 5 mm chest CT axial images, 1 mm and 5 mm chest CT coronal multi-plane recombination (MPR) images, and 5 mm chest CT coronal maximum intensity projection (MIP) images were used to observe the different characteristics of pneumoconiosis patients, and were compared and analyzed with DR chest radiographs to establish the experimental chest CT standards. The consistency of the profusion results between the experimental chest CT standards and GBZ 70-2015 Diagnosis of Occupational Pneumoconiosis was verified. <b>Results:</b> All the 66 objects were male, including 33 cases of stage Ⅰ pneumoconiosis, 17 cases of stage Ⅱ pneumoconiosis and 16 cases of stage Ⅲ pneumoconiosis. By observing five chest CT images of 66 objects, we found that chest CT images of different modes could clearly display and identify abnormal images such as small circular shadow, large shadow, small shadow aggregation, honeycomb glass shadow, flake glass shadow, uniform low-profusion glass shadow, mesh glass shadow, cable shadow, linear shadow, subpleural spinous shadow, subpleural nodules, various kinds of emphysema and lung texture distortion and fracture. Small shadow aggregation was usually accompanied by the appearance of large shadow. The vascular shadows in 5 mm CT images had good ductility, and small nodules were easy to distinguish. The coronal MIP image of 5 mm chest CT used edge enhancement technology, which was prone to small shadow fusion and fibrotic shadow fusion. The coronal MPR image of 5 mm chest CT was highly consistent with the DR chest radiographs in terms of the integrity of film reading. GBZ 70-2015 standard was used to compare the profusion of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, and the consistency test Kappa=0.64. GBZ 70-2015 standard and experimental chest CT standard were used to compare the profusion results of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, respectively, and the consistency test Kappa=0.80, with high consistency. <b>Conclusion:</b> 5 mm coronal MPR image is suitable for chest CT imaging in the diagnosis of pneumoconiosis. Following the selection path and method of GBZ 70-2015 profusion criterion, the established experimental chest CT standard in determining the profusion of small circular shadows in 5 mm coronal MPR images of chest CT with pneumoconiosis has a high consistency with GBZ 70-2015 standard.</p>","PeriodicalId":23958,"journal":{"name":"中华劳动卫生职业病杂志","volume":"42 5","pages":"359-369"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华劳动卫生职业病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121094-20221226-00607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To select chest CT image patterns for the diagnosis of pneumoconiosis and establish a method for determining the profusion of circular small shadows in chest CT. Methods: In April 2021, 66 cases of occupational pneumoconiosis patients with digital radiography (DR) chest radiographs and chest CT imaging data with circular small shadow as the main manifestations were selected as the study objects. 1.5 mm and 5 mm chest CT axial images, 1 mm and 5 mm chest CT coronal multi-plane recombination (MPR) images, and 5 mm chest CT coronal maximum intensity projection (MIP) images were used to observe the different characteristics of pneumoconiosis patients, and were compared and analyzed with DR chest radiographs to establish the experimental chest CT standards. The consistency of the profusion results between the experimental chest CT standards and GBZ 70-2015 Diagnosis of Occupational Pneumoconiosis was verified. Results: All the 66 objects were male, including 33 cases of stage Ⅰ pneumoconiosis, 17 cases of stage Ⅱ pneumoconiosis and 16 cases of stage Ⅲ pneumoconiosis. By observing five chest CT images of 66 objects, we found that chest CT images of different modes could clearly display and identify abnormal images such as small circular shadow, large shadow, small shadow aggregation, honeycomb glass shadow, flake glass shadow, uniform low-profusion glass shadow, mesh glass shadow, cable shadow, linear shadow, subpleural spinous shadow, subpleural nodules, various kinds of emphysema and lung texture distortion and fracture. Small shadow aggregation was usually accompanied by the appearance of large shadow. The vascular shadows in 5 mm CT images had good ductility, and small nodules were easy to distinguish. The coronal MIP image of 5 mm chest CT used edge enhancement technology, which was prone to small shadow fusion and fibrotic shadow fusion. The coronal MPR image of 5 mm chest CT was highly consistent with the DR chest radiographs in terms of the integrity of film reading. GBZ 70-2015 standard was used to compare the profusion of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, and the consistency test Kappa=0.64. GBZ 70-2015 standard and experimental chest CT standard were used to compare the profusion results of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, respectively, and the consistency test Kappa=0.80, with high consistency. Conclusion: 5 mm coronal MPR image is suitable for chest CT imaging in the diagnosis of pneumoconiosis. Following the selection path and method of GBZ 70-2015 profusion criterion, the established experimental chest CT standard in determining the profusion of small circular shadows in 5 mm coronal MPR images of chest CT with pneumoconiosis has a high consistency with GBZ 70-2015 standard.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[尘肺病胸部 CT 重构图像中圆形小阴影斑的评估方法研究]。
目的:选择用于诊断尘肺病的胸部 CT 图像模式,并建立胸部 CT 中圆形小阴影密集度的判定方法。方法:选取 2021 年 4 月 66 例职业性尘肺患者的数字X线胸片(DR)和胸部 CT 影像资料,以圆形小阴影为主要表现形式作为研究对象。采用1.5 mm和5 mm胸部CT轴位图像、1 mm和5 mm胸部CT冠状位多平面重组(MPR)图像、5 mm胸部CT冠状位最大强度投影(MIP)图像观察尘肺患者的不同特征,并与DR胸片进行对比分析,建立胸部CT实验标准。验证了胸部CT实验标准与GBZ 70-2015《职业性尘肺病诊断》之间的融合结果的一致性。结果:66例对象均为男性,其中Ⅰ期尘肺33例,Ⅱ期尘肺17例,Ⅲ期尘肺16例。通过观察 66 例对象的 5 张胸部 CT 图像,我们发现不同模式的胸部 CT 图像均能清晰显示和识别异常图像,如小圆形阴影、大阴影、小阴影聚集、蜂窝状玻璃阴影、片状玻璃阴影、均匀低灌注玻璃阴影、网状玻璃阴影、索状阴影、线状阴影、胸膜下棘状阴影、胸膜下结节、各种肺气肿以及肺纹理扭曲和断裂等。小阴影聚集通常伴随着大阴影的出现。5 毫米 CT 图像中的血管影延展性良好,小结节易于分辨。5 毫米胸部 CT 冠状 MIP 图像采用边缘增强技术,容易出现小阴影融合和纤维化阴影融合。5 毫米胸部 CT 冠状位 MPR 图像与 DR 胸片在读片完整性方面高度一致。采用GBZ 70-2015标准比较DR胸片与5 mm胸部CT冠状位MPR图像的66个对象的深度,一致性检验Kappa=0.64。采用 GBZ 70-2015 标准和实验胸部 CT 标准分别比较了 66 个对象的 DR 胸片和 5 mm 胸部 CT 冠状位 MPR 图像的切面结果,一致性检验 Kappa=0.80,一致性较高。结论:5 毫米冠状位 MPR 图像适用于尘肺病诊断的胸部 CT 成像。按照 GBZ 70-2015 浓淡标准的选择路径和方法,建立的尘肺病胸部 CT 5 mm 冠状位 MPR 图像小圆影浓淡判定实验标准与 GBZ 70-2015 标准具有较高的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中华劳动卫生职业病杂志
中华劳动卫生职业病杂志 Medicine-Medicine (all)
CiteScore
1.00
自引率
0.00%
发文量
9764
期刊介绍:
期刊最新文献
[3 cases of obstructive ventilation disorder caused by chronic butanedione exposure]. [Analysis of the improvement effect of DR high kilovoltage chest radiography image quality control in Tianjin City from 2022 to 2023]. [Analysis of the influencing factors of abnormal blood pressure and electrocardiogram in occupational motor vehicle drivers]. [Investigation and analysis of work-related musculoskeletal disorders among scientific researchers in computer workstation of an aerospace high-tech enterprise]. [Protective effect of astaxanthin on acute liver injury induced by α-amanitin in mice].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1