[Design and application of a new type of switchable semi-closed sputum suction device for transfer].

Xiumei Liu, Surui He
{"title":"[Design and application of a new type of switchable semi-closed sputum suction device for transfer].","authors":"Xiumei Liu, Surui He","doi":"10.3760/cma.j.cn121430-20230721-00539","DOIUrl":null,"url":null,"abstract":"<p><p>Sputum suction is a necessary measure to remove respiratory secretions and collect sputum specimens, and the traditional sputum suction device includes open and closed methods. However, the open sputum suction device can easily cause sputum splashing during operation, polluting the operator and the surrounding environment. The closed sputum suction device is more expensive than the open sputum suction device. Although it can be used repeatedly, the friction between the protective sleeve and the wall of the suction tube increases after repeated uses, which in turn affects the operation. In addition, the two sputum suction methods need to be connected to a sputum collector when the sputum specimen is collected. This process can easily lead to leakage and contamination of specimens, and at the same time increase the infection risk for patients. In order to overcome the above problems, the medical staff from the department of critical care medicine of the First Affiliated Hospital of Dalian Medical University invented a new type of switchable semi-closed sputum suction device, and obtained the National Utility Model Patent of China (ZL 2020 2 1564712.3). The device is composed of a suction device connection port, a sliding negative pressure switch, an adapter interface, a pipe body, a transparent film protective sleeve, a clip-on connection joint, and a sputum collector. The sliding negative pressure switch at the connection port of the suction device can realize one-person one-handed operation. The sputum collector is connected with the sputum suction device to ensure that the specimen is not exposed. The transparent film protective sleeve covers the sputum suction tube body to ensure that the whole process of sputum suction operation is pollution-free. The clip-on connection joint is connected with the artificial airway interface to avoid sputum splashing during sputum suction, and it is clamped immediately after operation to reduce environmental pollution. Compared with the existing sputum suction device, the new switchable semi-closed sputum suction device has a more reasonable design and lower cost, which is worthy of clinical promotion.</p>","PeriodicalId":24079,"journal":{"name":"Zhonghua wei zhong bing ji jiu yi xue","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua wei zhong bing ji jiu yi xue","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121430-20230721-00539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Sputum suction is a necessary measure to remove respiratory secretions and collect sputum specimens, and the traditional sputum suction device includes open and closed methods. However, the open sputum suction device can easily cause sputum splashing during operation, polluting the operator and the surrounding environment. The closed sputum suction device is more expensive than the open sputum suction device. Although it can be used repeatedly, the friction between the protective sleeve and the wall of the suction tube increases after repeated uses, which in turn affects the operation. In addition, the two sputum suction methods need to be connected to a sputum collector when the sputum specimen is collected. This process can easily lead to leakage and contamination of specimens, and at the same time increase the infection risk for patients. In order to overcome the above problems, the medical staff from the department of critical care medicine of the First Affiliated Hospital of Dalian Medical University invented a new type of switchable semi-closed sputum suction device, and obtained the National Utility Model Patent of China (ZL 2020 2 1564712.3). The device is composed of a suction device connection port, a sliding negative pressure switch, an adapter interface, a pipe body, a transparent film protective sleeve, a clip-on connection joint, and a sputum collector. The sliding negative pressure switch at the connection port of the suction device can realize one-person one-handed operation. The sputum collector is connected with the sputum suction device to ensure that the specimen is not exposed. The transparent film protective sleeve covers the sputum suction tube body to ensure that the whole process of sputum suction operation is pollution-free. The clip-on connection joint is connected with the artificial airway interface to avoid sputum splashing during sputum suction, and it is clamped immediately after operation to reduce environmental pollution. Compared with the existing sputum suction device, the new switchable semi-closed sputum suction device has a more reasonable design and lower cost, which is worthy of clinical promotion.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[新型可切换半封闭式转运吸痰装置的设计与应用]。
吸痰是清除呼吸道分泌物和采集痰标本的必要措施,传统的吸痰装置包括开放式和封闭式两种。但开放式吸痰装置在操作过程中容易造成痰液飞溅,污染操作者和周围环境。封闭式吸痰装置比开放式吸痰装置昂贵。虽然可以反复使用,但反复使用后,保护套与吸痰管壁之间的摩擦力会增大,进而影响操作。此外,这两种吸痰方法在采集痰液标本时都需要连接痰液收集器。这一过程容易导致标本泄漏和污染,同时也增加了患者感染的风险。为了克服上述问题,大连医科大学附属第一医院重症医学科的医护人员发明了一种新型可开关半封闭吸痰装置,并获得了中国国家实用新型专利(ZL 2020 2 1564712.3)。该装置由吸痰器连接口、滑动负压开关、转接接口、管体、透明膜保护套、卡扣式连接接头和痰液收集器组成。吸痰装置连接口的滑动负压开关可实现单人单手操作。痰液收集器与吸痰装置连接,确保标本不外露。透明薄膜保护套覆盖吸痰管体,确保吸痰操作全过程无污染。夹式连接接头与人工气道接口相连,避免吸痰过程中痰液飞溅,操作结束后立即夹紧,减少环境污染。与现有吸痰装置相比,新型可开关半封闭吸痰装置设计更合理,成本更低,值得临床推广。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Zhonghua wei zhong bing ji jiu yi xue
Zhonghua wei zhong bing ji jiu yi xue Medicine-Critical Care and Intensive Care Medicine
CiteScore
1.00
自引率
0.00%
发文量
42
期刊最新文献
[Annexin A1 activates the G protein-coupled formyl peptide receptor type 2-dependent endothelial nitric oxide synthase pathway to alleviate sepsis associated acute lung injury]. [Application of extracorporeal membrane oxygenation combined with renal replacement therapy in the treatment of war traumatic sepsis]. [Clinical characteristics and risk factors analysis of dengue fever incidence in Xishuangbanna, Yunnan Province in 2023]. [Design and application of an extracorporeal membrane oxygenation-specific line fixation device]. [Early diagnostic and prognosis prediction of circ_0054633 for acute lung injury/acute respiratory distress syndrome in children with severe pneumonia].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1