Małgorzata Grzegorczyk-Frańczak, W. Andrzejuk, Robert Hunek, Grzegorz Łagód
{"title":"Effect of Surface Hydrophobization on the Durability of Concrete with Cement Kiln Dust","authors":"Małgorzata Grzegorczyk-Frańczak, W. Andrzejuk, Robert Hunek, Grzegorz Łagód","doi":"10.12913/22998624/186212","DOIUrl":null,"url":null,"abstract":"The examinations of concrete involved partial substitution of cement with cement kiln dust (CKD) 0, 5, 10, 20 and 30%. The water/cement (w/c) ratio amounted to 0.36. The obtained findings pertaining to open porosity, density, and volumetric density were found to correlate with the capillary action and absorptivity of the analyzed types of concrete. With the maximum addition of CKD, i.e. 30%, open porosity decreased by 35%. In turn, CKD added in the amount of 5% resulted in a slightly reduced addition compressive strength, amounting to 1.3% and 2.1% fol - lowing 28 days and 56 days of concrete curing, respectively. After 28 days, the differences in strength were greater when the additive was supplied in higher amounts, i.e. 10%, 20%, and 30%, resulting in 6.5%, 13.4%, and 22.9% decrease, respectively, in spite of strength improvement. In terms of flexural and splitting tensile strengths, compa - rable relations were noted. As far as the frost resistance test results are concerned, the mass losses in all examined concretes were not significant, reaching up to 0.5%. The strength reduction in the case of the first three series of concretes was below 3%. When the CKD addition was increased to 20% and 30%, the value of the dynamic modu - lus of elasticity E c,s decreased to a greater degree, by 8.0% and 14.7%, respectively. The hydrophobization effect is best seen in CKD-free concrete. After the impregnation, the loss of mass following the frost test of the samples is reduced by half. With a higher CKD content, the hydrophobization effectiveness is insignificant. The most favour - able results were observed for hydrophobization with the oligomer-based preparation A1.","PeriodicalId":517116,"journal":{"name":"Advances in Science and Technology Research Journal","volume":"20 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Science and Technology Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12913/22998624/186212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The examinations of concrete involved partial substitution of cement with cement kiln dust (CKD) 0, 5, 10, 20 and 30%. The water/cement (w/c) ratio amounted to 0.36. The obtained findings pertaining to open porosity, density, and volumetric density were found to correlate with the capillary action and absorptivity of the analyzed types of concrete. With the maximum addition of CKD, i.e. 30%, open porosity decreased by 35%. In turn, CKD added in the amount of 5% resulted in a slightly reduced addition compressive strength, amounting to 1.3% and 2.1% fol - lowing 28 days and 56 days of concrete curing, respectively. After 28 days, the differences in strength were greater when the additive was supplied in higher amounts, i.e. 10%, 20%, and 30%, resulting in 6.5%, 13.4%, and 22.9% decrease, respectively, in spite of strength improvement. In terms of flexural and splitting tensile strengths, compa - rable relations were noted. As far as the frost resistance test results are concerned, the mass losses in all examined concretes were not significant, reaching up to 0.5%. The strength reduction in the case of the first three series of concretes was below 3%. When the CKD addition was increased to 20% and 30%, the value of the dynamic modu - lus of elasticity E c,s decreased to a greater degree, by 8.0% and 14.7%, respectively. The hydrophobization effect is best seen in CKD-free concrete. After the impregnation, the loss of mass following the frost test of the samples is reduced by half. With a higher CKD content, the hydrophobization effectiveness is insignificant. The most favour - able results were observed for hydrophobization with the oligomer-based preparation A1.