Wai Hong Lau, Wai Kiu Thomas Liu, Kwong Yuen Chiu, Man Hong Cheung, Amy Cheung, Ping Keung Chan, Vincent Wai Kwan Chan, Henry Fu
{"title":"Reducing edge loading and alignment outliers with image-free robotic-assisted unicompartmental knee arthroplasty: a case controlled study.","authors":"Wai Hong Lau, Wai Kiu Thomas Liu, Kwong Yuen Chiu, Man Hong Cheung, Amy Cheung, Ping Keung Chan, Vincent Wai Kwan Chan, Henry Fu","doi":"10.1186/s42836-024-00259-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Survivorship of medial unicompartmental knee arthroplasty (UKA) is technique-dependent. Correct femoral-tibial component positioning associates with improved survivorship. Image-free robotic-assisted unicompartmental knee arthroplasty enables preoperative and intraoperative planning of alignment and assessment of positioning prior to execution. This study aimed to compare the radiological outcomes between robotic-assisted UKA (R-UKA) and conventional UKA (C-UKA).</p><p><strong>Methods: </strong>This retrospective case control study involved 140 UKA (82 C-UKA and 58 R-UKA) performed at an academic institution between March 2016 to November 2020, with a mean follow-up of 3 years. Postoperative radiographs were evaluated for mechanical axis and femoral-tibial component position. Component position was measured by two methods: (1) femoral-tibial component contact point with reference to four medial-to-lateral quadrants of the tibial tray and (2) femoral-tibial component contact point deviation from the center of the tibial tray as a percentage of the tibial tray width. Baseline demographics and complications were recorded.</p><p><strong>Results: </strong>There was a higher mean component deviation in C-UKA compared with R-UKA using method 2 (17.2% vs. 12.8%; P = 0.007), but no difference in proportion of zonal outliers using method 1 (4 outliers in C-UKA, 5.1% vs. 1 outlier in R-UKA, 1.8%; P = 0.403). R-UKA showed no difference in mean mechanical alignment (C-UKA 5° vs. R-UKA 5°; P = 0.250). 2-year survivorship was 99% for C-UKA and 97% for R-UKA. Mean operative time was 18 min longer for R-UKA (P < 0.001).</p><p><strong>Conclusion: </strong>Image-free robotic-assisted UKA had improved component medio-lateral alignment compared with conventional technique.</p>","PeriodicalId":52831,"journal":{"name":"Arthroplasty","volume":"6 1","pages":"33"},"PeriodicalIF":2.3000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11151636/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00259-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Survivorship of medial unicompartmental knee arthroplasty (UKA) is technique-dependent. Correct femoral-tibial component positioning associates with improved survivorship. Image-free robotic-assisted unicompartmental knee arthroplasty enables preoperative and intraoperative planning of alignment and assessment of positioning prior to execution. This study aimed to compare the radiological outcomes between robotic-assisted UKA (R-UKA) and conventional UKA (C-UKA).
Methods: This retrospective case control study involved 140 UKA (82 C-UKA and 58 R-UKA) performed at an academic institution between March 2016 to November 2020, with a mean follow-up of 3 years. Postoperative radiographs were evaluated for mechanical axis and femoral-tibial component position. Component position was measured by two methods: (1) femoral-tibial component contact point with reference to four medial-to-lateral quadrants of the tibial tray and (2) femoral-tibial component contact point deviation from the center of the tibial tray as a percentage of the tibial tray width. Baseline demographics and complications were recorded.
Results: There was a higher mean component deviation in C-UKA compared with R-UKA using method 2 (17.2% vs. 12.8%; P = 0.007), but no difference in proportion of zonal outliers using method 1 (4 outliers in C-UKA, 5.1% vs. 1 outlier in R-UKA, 1.8%; P = 0.403). R-UKA showed no difference in mean mechanical alignment (C-UKA 5° vs. R-UKA 5°; P = 0.250). 2-year survivorship was 99% for C-UKA and 97% for R-UKA. Mean operative time was 18 min longer for R-UKA (P < 0.001).
Conclusion: Image-free robotic-assisted UKA had improved component medio-lateral alignment compared with conventional technique.