Analysis on the delivery quality assurance using SunCHECK for the VMAT in halcyon linear accelerator

IF 0.8 4区 物理与天体物理 Q3 PHYSICS, MULTIDISCIPLINARY Journal of the Korean Physical Society Pub Date : 2024-06-04 DOI:10.1007/s40042-024-01106-7
Shinhaeng Cho, Yong Hyub Kim, Jea-Uk Jeong, Mee Sun Yoon, Taek-Keun Nam, Sung-Ja Ahn, Ju-Young Song
{"title":"Analysis on the delivery quality assurance using SunCHECK for the VMAT in halcyon linear accelerator","authors":"Shinhaeng Cho,&nbsp;Yong Hyub Kim,&nbsp;Jea-Uk Jeong,&nbsp;Mee Sun Yoon,&nbsp;Taek-Keun Nam,&nbsp;Sung-Ja Ahn,&nbsp;Ju-Young Song","doi":"10.1007/s40042-024-01106-7","DOIUrl":null,"url":null,"abstract":"<div><p>This study evaluated the dosimetric accuracy of SunCHECK, a calculation-based IMRT DQA program, when applied to VMAT DQA for the Halcyon LINAC. Virtual VMAT treatment plans were generated utilizing a Delta4 Phantom + diode detector array device to analyze the accuracy of the dose calculation algorithm in SunCHECK. The analysis revealed a strong correlation between the calculated dose in SunCHECK, the planned dose, and the measured delivery dose. The characteristics of dose distribution changes calculated by SunCHECK in the event of MLC errors during VMAT beam delivery were analyzed additionally. After delivering a beam with MLC position errors, the dosimetric error evaluated through log file-based calculations were compared with the error analysis findings obtained from measurements using the Delta4 Phantom + . The dosimetric error calculated based on the log file using SunCHECK showed a similar trend to the dose error calculated through the conventional measurement-based DQA method using a Delta4 Phantom + . The results of this study validate SunCHECK’s accuracy in dose calculation and analysis of dosimetric errors resulting from MLC position errors, thereby confirming its efficacy in VMAT DQA using the Halcyon LINAC.</p></div>","PeriodicalId":677,"journal":{"name":"Journal of the Korean Physical Society","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Physical Society","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s40042-024-01106-7","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the dosimetric accuracy of SunCHECK, a calculation-based IMRT DQA program, when applied to VMAT DQA for the Halcyon LINAC. Virtual VMAT treatment plans were generated utilizing a Delta4 Phantom + diode detector array device to analyze the accuracy of the dose calculation algorithm in SunCHECK. The analysis revealed a strong correlation between the calculated dose in SunCHECK, the planned dose, and the measured delivery dose. The characteristics of dose distribution changes calculated by SunCHECK in the event of MLC errors during VMAT beam delivery were analyzed additionally. After delivering a beam with MLC position errors, the dosimetric error evaluated through log file-based calculations were compared with the error analysis findings obtained from measurements using the Delta4 Phantom + . The dosimetric error calculated based on the log file using SunCHECK showed a similar trend to the dose error calculated through the conventional measurement-based DQA method using a Delta4 Phantom + . The results of this study validate SunCHECK’s accuracy in dose calculation and analysis of dosimetric errors resulting from MLC position errors, thereby confirming its efficacy in VMAT DQA using the Halcyon LINAC.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 SunCHECK 对 halcyon 直线加速器中的 VMAT 的交付质量保证进行分析
本研究评估了基于计算的 IMRT DQA 程序 SunCHECK 应用于 Halcyon LINAC 的 VMAT DQA 时的剂量测定准确性。利用 Delta4 Phantom + 二极管探测器阵列设备生成虚拟 VMAT 治疗计划,以分析 SunCHECK 中剂量计算算法的准确性。分析结果表明,SunCHECK 中的计算剂量、计划剂量和测量的输出剂量之间存在很强的相关性。此外,还分析了在 VMAT 射束输送过程中出现 MLC 误差时 SunCHECK 计算出的剂量分布变化特征。在输送存在 MLC 位置误差的射束后,将通过日志文件计算得出的剂量学误差与使用 Delta4 Phantom + 进行测量得出的误差分析结果进行了比较。使用 SunCHECK 根据日志文件计算出的剂量学误差与使用 Delta4 Phantom + 通过传统的基于测量的 DQA 方法计算出的剂量误差显示出相似的趋势。这项研究结果验证了 SunCHECK 在剂量计算和分析 MLC 位置误差导致的剂量误差方面的准确性,从而确认了其在使用 Halcyon LINAC 进行 VMAT DQA 方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of the Korean Physical Society
Journal of the Korean Physical Society PHYSICS, MULTIDISCIPLINARY-
CiteScore
1.20
自引率
16.70%
发文量
276
审稿时长
5.5 months
期刊介绍: The Journal of the Korean Physical Society (JKPS) covers all fields of physics spanning from statistical physics and condensed matter physics to particle physics. The manuscript to be published in JKPS is required to hold the originality, significance, and recent completeness. The journal is composed of Full paper, Letters, and Brief sections. In addition, featured articles with outstanding results are selected by the Editorial board and introduced in the online version. For emphasis on aspect of international journal, several world-distinguished researchers join the Editorial board. High quality of papers may be express-published when it is recommended or requested.
期刊最新文献
Erratum: Comparative analysis of single and triple material 10 nm Tri-gate FinFET Revisit to the fluid Love numbers and the permanent tide of the Earth Dictionary learning-based denoising algorithm with expected patch log likelihood in diffusion-weighted magnetic resonance image Synthesis and characterization of Fe-doped ZnO films for enhanced NO2 gas-sensing applications Quantum discord in the early universe with non-trivial sound speed
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1