Two-dimensional electro-optical multiphoton microscopy.

IF 4.8 2区 医学 Q1 NEUROSCIENCES Neurophotonics Pub Date : 2024-04-01 Epub Date: 2024-06-05 DOI:10.1117/1.NPh.11.2.025005
Deano M Farinella, Samuel Stanek, Harishankar Jayakumar, Zachary L Newman, Jacob Gable, James Leger, Aaron Kerlin
{"title":"Two-dimensional electro-optical multiphoton microscopy.","authors":"Deano M Farinella, Samuel Stanek, Harishankar Jayakumar, Zachary L Newman, Jacob Gable, James Leger, Aaron Kerlin","doi":"10.1117/1.NPh.11.2.025005","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>The development of genetically encoded fluorescent indicators of neural activity with millisecond dynamics has generated demand for ever faster two-photon (2P) imaging systems, but acoustic and mechanical beam scanning technologies are approaching fundamental limits. We demonstrate that potassium tantalate niobate (KTN) electro-optical deflectors (EODs), which are not subject to the same fundamental limits, are capable of ultrafast two-dimensional (2D) 2P imaging <i>in vivo</i>.</p><p><strong>Aim: </strong>To determine if KTN-EODs are suitable for 2P imaging, compatible with 2D scanning, and capable of ultrafast <i>in vivo</i> imaging of genetically encoded indicators with millisecond dynamics.</p><p><strong>Approach: </strong>The performance of a commercially available KTN-EOD was characterized across a range of drive frequencies and laser parameters relevant to <i>in vivo</i> 2P microscopy. A second KTN-EOD was incorporated into a dual-axis scan module, and the system was validated by imaging signals <i>in vivo</i> from ASAP3, a genetically encoded voltage indicator.</p><p><strong>Results: </strong>Optimal KTN-EOD deflection of laser light with a central wavelength of 960 nm was obtained up to the highest average powers and pulse intensities tested (power: 350 mW; pulse duration: 118 fs). Up to 32 resolvable spots per line at a 560 kHz line scan rate could be obtained with single-axis deflection. The complete dual-axis EO 2P microscope was capable of imaging a <math><mrow><mn>13</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> by <math><mrow><mn>13</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> field-of-view at over 10 kHz frame rate with <math><mrow><mo>∼</mo><mn>0.5</mn><mtext>  </mtext><mi>μ</mi><mi>m</mi></mrow></math> lateral resolution. We demonstrate <i>in vivo</i> imaging of neurons expressing ASAP3 with high temporal resolution.</p><p><strong>Conclusions: </strong>We demonstrate the suitability of KTN-EODs for ultrafast 2P cellular imaging <i>in vivo</i>, providing a foundation for future high-performance microscopes to incorporate emerging advances in KTN-based scanning technology.</p>","PeriodicalId":54335,"journal":{"name":"Neurophotonics","volume":"11 2","pages":"025005"},"PeriodicalIF":4.8000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11151658/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurophotonics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.NPh.11.2.025005","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: The development of genetically encoded fluorescent indicators of neural activity with millisecond dynamics has generated demand for ever faster two-photon (2P) imaging systems, but acoustic and mechanical beam scanning technologies are approaching fundamental limits. We demonstrate that potassium tantalate niobate (KTN) electro-optical deflectors (EODs), which are not subject to the same fundamental limits, are capable of ultrafast two-dimensional (2D) 2P imaging in vivo.

Aim: To determine if KTN-EODs are suitable for 2P imaging, compatible with 2D scanning, and capable of ultrafast in vivo imaging of genetically encoded indicators with millisecond dynamics.

Approach: The performance of a commercially available KTN-EOD was characterized across a range of drive frequencies and laser parameters relevant to in vivo 2P microscopy. A second KTN-EOD was incorporated into a dual-axis scan module, and the system was validated by imaging signals in vivo from ASAP3, a genetically encoded voltage indicator.

Results: Optimal KTN-EOD deflection of laser light with a central wavelength of 960 nm was obtained up to the highest average powers and pulse intensities tested (power: 350 mW; pulse duration: 118 fs). Up to 32 resolvable spots per line at a 560 kHz line scan rate could be obtained with single-axis deflection. The complete dual-axis EO 2P microscope was capable of imaging a 13  μm by 13  μm field-of-view at over 10 kHz frame rate with 0.5  μm lateral resolution. We demonstrate in vivo imaging of neurons expressing ASAP3 with high temporal resolution.

Conclusions: We demonstrate the suitability of KTN-EODs for ultrafast 2P cellular imaging in vivo, providing a foundation for future high-performance microscopes to incorporate emerging advances in KTN-based scanning technology.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
二维电子光学多光子显微镜。
意义重大:具有毫秒级动态的神经活动基因编码荧光指示器的开发,催生了对更快的双光子(2P)成像系统的需求,但声学和机械光束扫描技术已接近基本极限。我们证明,钽酸铌酸钾(KTN)电子光学偏转器(EOD)不受同样的基本限制,能够在体内进行超快二维(2D)双光子成像。目的:确定 KTN-EOD 是否适用于双光子成像,是否与二维扫描兼容,是否能够在体内对具有毫秒级动态的基因编码指标进行超快成像:方法:在与活体 2P 显微镜相关的驱动频率和激光参数范围内,对商用 KTN-EOD 的性能进行了鉴定。在双轴扫描模块中加入了第二个 KTN-EOD,并通过对基因编码电压指示器 ASAP3 的体内信号成像对系统进行了验证:结果:在测试的最高平均功率和脉冲强度(功率:350 mW;脉冲持续时间:118 fs)条件下,中心波长为 960 nm 的 KTN-EOD 可获得最佳激光偏转。在 560 kHz 的行扫描速率下,单轴偏转最多可获得每行 32 个可分辨光斑。完整的双轴 EO 2P 显微镜能够以超过 10 kHz 的帧速率对 13 μm x 13 μm 的视场进行成像,横向分辨率为 0.5 μm。我们展示了表达 ASAP3 的神经元在体内的高时间分辨率成像:我们证明了 KTN-EODs 适用于体内超快 2P 细胞成像,为未来高性能显微镜采用基于 KTN 的新兴扫描技术奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Neurophotonics
Neurophotonics Neuroscience-Neuroscience (miscellaneous)
CiteScore
7.20
自引率
11.30%
发文量
114
审稿时长
21 weeks
期刊介绍: At the interface of optics and neuroscience, Neurophotonics is a peer-reviewed journal that covers advances in optical technology applicable to study of the brain and their impact on the basic and clinical neuroscience applications.
期刊最新文献
Viscocohesive hyaluronan gel enhances stability of intravital multiphoton imaging with subcellular resolution. Zika virus encephalitis causes transient reduction of functional cortical connectivity. Early changes in spatiotemporal dynamics of remapped circuits and global networks predict functional recovery after stroke in mice. Distribution of spine classes shows intra-neuronal dendritic heterogeneity in mouse cortex. Expansion microscopy reveals neural circuit organization in genetic animal models.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1