Method development with high-throughput enhanced matrix removal followed by UHPLC-QqQ-MS/MS for analysis of grape polyphenol metabolites in human urine

IF 2.8 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Journal of Chromatography B Pub Date : 2024-06-03 DOI:10.1016/j.jchromb.2024.124189
Weiting Lyu , Zhiya Yin , Lingjun Xie , Giulio M. Pasinetti , James W. Murrough , Maxine Marchidan , Elizabeth Karpman , Matthew Dobbs , Mario G. Ferruzzi , James E. Simon , Qingli Wu
{"title":"Method development with high-throughput enhanced matrix removal followed by UHPLC-QqQ-MS/MS for analysis of grape polyphenol metabolites in human urine","authors":"Weiting Lyu ,&nbsp;Zhiya Yin ,&nbsp;Lingjun Xie ,&nbsp;Giulio M. Pasinetti ,&nbsp;James W. Murrough ,&nbsp;Maxine Marchidan ,&nbsp;Elizabeth Karpman ,&nbsp;Matthew Dobbs ,&nbsp;Mario G. Ferruzzi ,&nbsp;James E. Simon ,&nbsp;Qingli Wu","doi":"10.1016/j.jchromb.2024.124189","DOIUrl":null,"url":null,"abstract":"<div><p>Grape and grape derived products contain many bioactive phenolics which have a variety of impacts on health. Following oral ingestion, the phenolic compounds and their metabolites may be detectable in human urine. However, developing a reliable method for the analysis of phenolic compounds in urine is challenging. In this work, we developed and validated a new high-throughput, sensitive and reproducible analytical method for the simultaneous analysis of 31 grape phenolic compounds and metabolites using Oasis PRiME HLB cleanup for sample preparation combined with ultra-performance liquid chromatography with triple quadrupole tandem mass spectrometry (UHPLC-QqQ-MS/MS). Using this new method, the accuracy achieved was 69.3 % ∼ 134.9 % (except for six compounds), and the recovery achieved was 52.4 % ∼ 134.7 % (except for two very polar compounds). For each of the 31 target analytes, the value of intra-day precision was less than 14.3 %. The value of inter-day precision was slightly higher than intra-day precision, with a range of 0.7 % ∼ 19.1 %. We report for the first time on the effect of gender and BMI on the accuracy and recovery of human urine samples, and results from analysis of variance (ANOVA), and principal component analysis (PCA) indicated there was no difference in the value of accuracy and recovery between different gender or BMI (&gt;30) using our purposed cleanup and UHPLC-QqQ-MS/MS method. Overall, this newly developed method could serve as a powerful tool for analyzing grape phenolic compounds and metabolites in human urine samples.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224001983","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Grape and grape derived products contain many bioactive phenolics which have a variety of impacts on health. Following oral ingestion, the phenolic compounds and their metabolites may be detectable in human urine. However, developing a reliable method for the analysis of phenolic compounds in urine is challenging. In this work, we developed and validated a new high-throughput, sensitive and reproducible analytical method for the simultaneous analysis of 31 grape phenolic compounds and metabolites using Oasis PRiME HLB cleanup for sample preparation combined with ultra-performance liquid chromatography with triple quadrupole tandem mass spectrometry (UHPLC-QqQ-MS/MS). Using this new method, the accuracy achieved was 69.3 % ∼ 134.9 % (except for six compounds), and the recovery achieved was 52.4 % ∼ 134.7 % (except for two very polar compounds). For each of the 31 target analytes, the value of intra-day precision was less than 14.3 %. The value of inter-day precision was slightly higher than intra-day precision, with a range of 0.7 % ∼ 19.1 %. We report for the first time on the effect of gender and BMI on the accuracy and recovery of human urine samples, and results from analysis of variance (ANOVA), and principal component analysis (PCA) indicated there was no difference in the value of accuracy and recovery between different gender or BMI (>30) using our purposed cleanup and UHPLC-QqQ-MS/MS method. Overall, this newly developed method could serve as a powerful tool for analyzing grape phenolic compounds and metabolites in human urine samples.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用高通量增强型基质去除技术和超高效液相色谱-QqQ-MS/MS,开发分析人体尿液中葡萄多酚代谢物的方法
葡萄和葡萄衍生产品中含有许多生物活性酚类物质,对健康有多种影响。口服后,人体尿液中可检测到酚类化合物及其代谢物。然而,开发一种可靠的方法来分析尿液中的酚类化合物具有挑战性。在这项工作中,我们采用 Oasis PRiME HLB 净化技术进行样品制备,并结合超高效液相色谱-三重四极杆串联质谱(UHPLC-QqQ-MS/MS),开发并验证了一种新的高通量、灵敏且可重复的分析方法,用于同时分析 31 种葡萄酚类化合物和代谢物。使用这种新方法,准确度达到 69.3 % ∼ 134.9 %(六种化合物除外),回收率达到 52.4 % ∼ 134.7 %(两种极性化合物除外)。31 种目标分析物的日内精密度值均小于 14.3%。日间精度略高于日内精度,范围为 0.7 % ∼ 19.1 %。我们首次报道了性别和体重指数对人体尿样准确度和回收率的影响,方差分析(ANOVA)和主成分分析(PCA)的结果表明,使用我们特制的净化装置和超高效液相色谱-质谱-质谱/多反应监测(UHPLC-QqQ-MS/MS)方法,不同性别和体重指数(30)之间的准确度和回收率没有差异。总之,这种新开发的方法可作为分析人体尿样中葡萄酚类化合物和代谢物的有力工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Chromatography B
Journal of Chromatography B 医学-分析化学
CiteScore
5.60
自引率
3.30%
发文量
306
审稿时长
44 days
期刊介绍: The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis. Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches. Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.
期刊最新文献
Development and application of UPLC-Q-Orbitrap HRMS methods for the determination of eight metabolites of p-chloronitrobenzene in human urine Simultaneous determination of total homocysteine, methionine, methylmalonic acid and 2-methylcitric acid in dried blood spots by ultra-performance liquid chromatography–tandem mass spectrometry Optimized isolation and purification of Shaoyao Gancao decoction using macroporous resin Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samples. Identification and characterization of GSK-9089 metabolites through high resolution-mass spectrometry based in vitro and in vivo rat biological sample analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1