Roberto Sorrentino, Gennaro Ruggiero, Renato Leone, Maria Irene Di Mauro, Edoardo Ferrari Cagidiaco, Tim Joda, Lucio Lo Russo, Fernando Zarone
{"title":"Influence of different palatal morphologies on the accuracy of intraoral scanning of the edentulous maxilla: A three-dimensional analysis.","authors":"Roberto Sorrentino, Gennaro Ruggiero, Renato Leone, Maria Irene Di Mauro, Edoardo Ferrari Cagidiaco, Tim Joda, Lucio Lo Russo, Fernando Zarone","doi":"10.2186/jpr.JPR_D_23_00175","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae.</p><p><strong>Methods: </strong>Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W), or smooth palates (S), resulting in six groups: WF, WM, WD and SF, SM, SD. Ten scans were performed for each group; standard tessellation language files obtained were imported into a software to measure trueness and precision in micrometer. Trueness was calculated as the mean of the standard deviation values obtained by superimposing each scan onto the reference scan. Precision was achieved by overlapping each scan with that with the best trueness in the group. Descriptive and post-hoc analyses were conducted.</p><p><strong>Results: </strong>The mean values for trueness were as follows: WM=48.7±4.7, WD=161.7±18.4, WF=85.9±16, SM=48.1±2.4, SD=349.9±8.8, and SF=349.1±25.5. The precision values were as follows: WM=46.7±7.3, WD=46.9±9, WF=48.9±6.7, SM=46±2.7, SD=105.9±17.4, SF=72.6±10.8. Significant differences were observed for trueness between SM and SD (P < 0.001), SM and SF (P < 0.001), and WF and SF (P = 0.003); whereas for precision, significant differences were reported between WD and SD (P = 0.015). Regarding trueness and precision, no difference was found between WM and SM (P = 1.0).</p><p><strong>Conclusions: </strong>Medium palatal depth showed the best accuracy. The mean accuracy values were within the clinical acceptability thresholds for all palatal morphologies. The presence of rugae improved the precision of deeper palates and the trueness of flat palates. No differences were observed in the medium palates with or without rugae.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"634-642"},"PeriodicalIF":3.2000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of prosthodontic research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_23_00175","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae.
Methods: Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W), or smooth palates (S), resulting in six groups: WF, WM, WD and SF, SM, SD. Ten scans were performed for each group; standard tessellation language files obtained were imported into a software to measure trueness and precision in micrometer. Trueness was calculated as the mean of the standard deviation values obtained by superimposing each scan onto the reference scan. Precision was achieved by overlapping each scan with that with the best trueness in the group. Descriptive and post-hoc analyses were conducted.
Results: The mean values for trueness were as follows: WM=48.7±4.7, WD=161.7±18.4, WF=85.9±16, SM=48.1±2.4, SD=349.9±8.8, and SF=349.1±25.5. The precision values were as follows: WM=46.7±7.3, WD=46.9±9, WF=48.9±6.7, SM=46±2.7, SD=105.9±17.4, SF=72.6±10.8. Significant differences were observed for trueness between SM and SD (P < 0.001), SM and SF (P < 0.001), and WF and SF (P = 0.003); whereas for precision, significant differences were reported between WD and SD (P = 0.015). Regarding trueness and precision, no difference was found between WM and SM (P = 1.0).
Conclusions: Medium palatal depth showed the best accuracy. The mean accuracy values were within the clinical acceptability thresholds for all palatal morphologies. The presence of rugae improved the precision of deeper palates and the trueness of flat palates. No differences were observed in the medium palates with or without rugae.
期刊介绍:
Journal of Prosthodontic Research is published 4 times annually, in January, April, July, and October, under supervision by the Editorial Board of Japan Prosthodontic Society, which selects all materials submitted for publication.
Journal of Prosthodontic Research originated as an official journal of Japan Prosthodontic Society. It has recently developed a long-range plan to become the most prestigious Asian journal of dental research regarding all aspects of oral and occlusal rehabilitation, fixed/removable prosthodontics, oral implantology and applied oral biology and physiology. The Journal will cover all diagnostic and clinical management aspects necessary to reestablish subjective and objective harmonious oral aesthetics and function.
The most-targeted topics:
1) Clinical Epidemiology and Prosthodontics
2) Fixed/Removable Prosthodontics
3) Oral Implantology
4) Prosthodontics-Related Biosciences (Regenerative Medicine, Bone Biology, Mechanobiology, Microbiology/Immunology)
5) Oral Physiology and Biomechanics (Masticating and Swallowing Function, Parafunction, e.g., bruxism)
6) Orofacial Pain and Temporomandibular Disorders (TMDs)
7) Adhesive Dentistry / Dental Materials / Aesthetic Dentistry
8) Maxillofacial Prosthodontics and Dysphagia Rehabilitation
9) Digital Dentistry
Prosthodontic treatment may become necessary as a result of developmental or acquired disturbances in the orofacial region, of orofacial trauma, or of a variety of dental and oral diseases and orofacial pain conditions.
Reviews, Original articles, technical procedure and case reports can be submitted. Letters to the Editor commenting on papers or any aspect of Journal of Prosthodontic Research are welcomed.