Shunt-mediated decompression sickness in a compressed air worker with an atrial septal defect.

IF 0.8 4区 医学 Q4 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Diving and hyperbaric medicine Pub Date : 2024-06-30 DOI:10.28920/dhm54.2.127-132
Andrew P Colvin, Ryan Hogg, Peter T Wilmshurst
{"title":"Shunt-mediated decompression sickness in a compressed air worker with an atrial septal defect.","authors":"Andrew P Colvin, Ryan Hogg, Peter T Wilmshurst","doi":"10.28920/dhm54.2.127-132","DOIUrl":null,"url":null,"abstract":"<p><p>We report a compressed air worker who had diffuse cutaneous decompression sickness with pain in his left shoulder and visual disturbance characteristic of migraine aura after only his third hyperbaric exposure. The maximum pressure was 253 kPa gauge with oxygen decompression using the Swanscombe Oxygen Decompression Table. He was found to have a very large right-to-left shunt across a 9 mm atrial septal defect. He had transcatheter closure of the defect but had some residual shunting with release of a Valsalva manoeuvre. Thirty-two other tunnel workers undertook the same pressure profile and activities in the same working conditions during the maintenance of a tunnel boring machine for a total of 233 similar exposures and were unaffected. As far as we are aware this is the first report of shunt-mediated decompression sickness in a hyperbaric tunnel worker in the United Kingdom and the second case reported worldwide. These cases suggest that shunt-mediated decompression sickness should be considered to be an occupational risk in modern compressed air working. A right-to-left shunt in a compressed air worker should be managed in accordance with established clinical guidance for divers.</p>","PeriodicalId":11296,"journal":{"name":"Diving and hyperbaric medicine","volume":"54 2","pages":"127-132"},"PeriodicalIF":0.8000,"publicationDate":"2024-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11444913/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diving and hyperbaric medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.28920/dhm54.2.127-132","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

We report a compressed air worker who had diffuse cutaneous decompression sickness with pain in his left shoulder and visual disturbance characteristic of migraine aura after only his third hyperbaric exposure. The maximum pressure was 253 kPa gauge with oxygen decompression using the Swanscombe Oxygen Decompression Table. He was found to have a very large right-to-left shunt across a 9 mm atrial septal defect. He had transcatheter closure of the defect but had some residual shunting with release of a Valsalva manoeuvre. Thirty-two other tunnel workers undertook the same pressure profile and activities in the same working conditions during the maintenance of a tunnel boring machine for a total of 233 similar exposures and were unaffected. As far as we are aware this is the first report of shunt-mediated decompression sickness in a hyperbaric tunnel worker in the United Kingdom and the second case reported worldwide. These cases suggest that shunt-mediated decompression sickness should be considered to be an occupational risk in modern compressed air working. A right-to-left shunt in a compressed air worker should be managed in accordance with established clinical guidance for divers.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一名患有房间隔缺损的压缩空气工人的分流介导的减压病。
我们报告了一名压缩空气工人仅在第三次高压氧暴露后就出现了弥漫性皮肤减压病,左肩疼痛,并伴有偏头痛先兆的视觉障碍。使用 Swanscombe 氧气减压表进行氧气减压时,最大压力为 253 kPa。他被发现在 9 毫米的房间隔缺损处有一个非常大的右向左分流。他接受了经导管的缺损闭合术,但在做瓦尔萨尔瓦动作时仍有一些残留的分流。另外 32 名隧道工人在维护一台隧道掘进机时,在相同的工作条件下进行了相同的压力曲线和活动,总共接触了 233 次类似的压力,但均未受到影响。据我们所知,这是英国第一例关于高压氧隧道工人分流介导的减压病的报告,也是全球第二例报告。这些病例表明,分流介导的减压病应被视为现代压缩空气工作中的一种职业风险。压缩空气工人的右至左分流应根据潜水员的既定临床指南进行处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diving and hyperbaric medicine
Diving and hyperbaric medicine 医学-公共卫生、环境卫生与职业卫生
CiteScore
1.70
自引率
22.20%
发文量
37
审稿时长
>12 weeks
期刊介绍: Diving and Hyperbaric Medicine (DHM) is the combined journal of the South Pacific Underwater Medicine Society (SPUMS) and the European Underwater and Baromedical Society (EUBS). It seeks to publish papers of high quality on all aspects of diving and hyperbaric medicine of interest to diving medical professionals, physicians of all specialties, scientists, members of the diving and hyperbaric industries, and divers. Manuscripts must be offered exclusively to Diving and Hyperbaric Medicine, unless clearly authenticated copyright exemption accompaniesthe manuscript. All manuscripts will be subject to peer review. Accepted contributions will also be subject to editing.
期刊最新文献
Acoustic emission, an innovative diagnosis tool for therapeutic hyperbaric chambers: or how to requalify safely using pneumatic pressure test. Arterial dissection in scuba divers: a potential adverse manifestation of the physiological effects of immersion. Bispectral index with density spectral array (BIS-DSA) monitoring in a patient with inner ear and cerebral decompression sickness. Evaluation of a new hyperbaric oxygen ventilator during pressure-controlled ventilation. Hyperbaric medicine and climate footprint.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1