{"title":"Longevity of different abutments placed on narrow diameter implants: Assessment of structural damage and loosening","authors":"","doi":"10.1016/j.dental.2024.06.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>To evaluate structural damage and loosening of abutments placed on narrow diameter implants after cyclic fatigue.</p></div><div><h3>Methods</h3><p><span>Sixty Morse taper narrow diameter implants (Neodent, Brazil) received two types of abutments (1PA- one-piece abutment or 2PA- two-piece abutment), which were randomly divided into 3 fatigue experiments (n = 10). The implants were placed into a customized supporting holder and a software-assisted digital torque wrench secured the manufacturer recommended torque for each abutment. Cone beam computed tomography (CBCT) scans were acquired, before and after fatigue, and post-processed (software e-Vol DX) to assess damage and abutment displacement. The boundary fatigue method was adapted to use 2 × 10</span><sup>6</sup> cycles, 2 Hz of frequency and constant peak load of 80 N (first experiment) that varied according to the failure rate of previous specimens (second and third experiments). Failure was evaluated using CBCT scans and removal torque values. Data were used to estimate long-term torque degradation, probability of failure and Weibull modulus (software ALTA PRO9).</p></div><div><h3>Results</h3><p>All 2PA specimens became loosen independently of the applied fatigue load, and structural bending was observed in 14 abutments. Eight 1PA got loosen during the fatigue experiment. The Weibull analysis showed a lower modulus (<em>m</em> = 1.0; 0.7, 1.4) for 1PA than for 2PA (<em>m</em> = 2.6; 2, 3.4) resulting in longer predicted lifetimes and slower torque degradation for 1PA than for 2PA specimens.</p></div><div><h3>Significance</h3><p>1PA showed greater long-term survival probability than 2PA. Predicting the lifetime and mechanical behavior of implant-abutment systems are useful information to clinicians during the decision-making process of oral rehabilitations.</p></div>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":"40 9","pages":"Pages 1332-1340"},"PeriodicalIF":4.6000,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0109564124001337","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
To evaluate structural damage and loosening of abutments placed on narrow diameter implants after cyclic fatigue.
Methods
Sixty Morse taper narrow diameter implants (Neodent, Brazil) received two types of abutments (1PA- one-piece abutment or 2PA- two-piece abutment), which were randomly divided into 3 fatigue experiments (n = 10). The implants were placed into a customized supporting holder and a software-assisted digital torque wrench secured the manufacturer recommended torque for each abutment. Cone beam computed tomography (CBCT) scans were acquired, before and after fatigue, and post-processed (software e-Vol DX) to assess damage and abutment displacement. The boundary fatigue method was adapted to use 2 × 106 cycles, 2 Hz of frequency and constant peak load of 80 N (first experiment) that varied according to the failure rate of previous specimens (second and third experiments). Failure was evaluated using CBCT scans and removal torque values. Data were used to estimate long-term torque degradation, probability of failure and Weibull modulus (software ALTA PRO9).
Results
All 2PA specimens became loosen independently of the applied fatigue load, and structural bending was observed in 14 abutments. Eight 1PA got loosen during the fatigue experiment. The Weibull analysis showed a lower modulus (m = 1.0; 0.7, 1.4) for 1PA than for 2PA (m = 2.6; 2, 3.4) resulting in longer predicted lifetimes and slower torque degradation for 1PA than for 2PA specimens.
Significance
1PA showed greater long-term survival probability than 2PA. Predicting the lifetime and mechanical behavior of implant-abutment systems are useful information to clinicians during the decision-making process of oral rehabilitations.
期刊介绍:
Dental Materials publishes original research, review articles, and short communications.
Academy of Dental Materials members click here to register for free access to Dental Materials online.
The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology.
Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.