Eric C.J. Claas , Youssef Rezek , Luuk Sterk , Anne Russcher , Fabienne B. Verhees , Anja Heijne-Tol , Paul H.M. Smits , Roel H.T. Nijhuis
{"title":"Diagnosing viral gastro-enteritis using the fully automated sample-in, result-out STARlet All in one system (AIOS)","authors":"Eric C.J. Claas , Youssef Rezek , Luuk Sterk , Anne Russcher , Fabienne B. Verhees , Anja Heijne-Tol , Paul H.M. Smits , Roel H.T. Nijhuis","doi":"10.1016/j.jviromet.2024.114985","DOIUrl":null,"url":null,"abstract":"<div><p>The STARlet All-In-One system is a modular platform that integrates the complete molecular diagnostic workflow from nucleic acid extraction of clinical samples to PCR set-up and amplification. The platform was evaluated in comparison with laboratory developed tests (LDT) on fecal samples from patients with suspected viral gastro-enteritis. In a retrospective study, 72 positive samples were analysed, including all pathogens detected by the Seegene Allplex™ GI-virus assay, adenovirus, astrovirus, norovirus GI and GII, sapovirus, and rotavirus. Concordant results were obtained for 69 samples (96 %). Three discordant results were observed, one norovirus GII positive that gave an invalid result in the AIOS and two samples that were negative in the AIOS. One adenovirus positive that was subtyped as a genotype 2 virus, which is not associated with gastro-enteritis, and a sapovirus. In the prospective part of the study, 661 fecal samples were included. A total of 61 positive samples were detected, of which 60 were also detected by the AIOS. One norovirus GII positive sample (C<sub>T</sub> 35.2) was tested negative in the AIOS. Two additional sapovirus positive samples, C<sub>T</sub> 37 and 38, were detected by the AIOS but not by the LDT. The STARlet All-In-One platforms results in an automated molecular workflow with reduced hands-on time and enables running assays during out of office hours. Application of the Seegene Allplex™ GI-virus assay showed excellent concordance to the current diagnostic LDT. In a prospective comparison, only three discordant results were observed, all with C<sub>T</sub> values over 35 and therefore unlikely of clinical relevance.</p></div>","PeriodicalId":17663,"journal":{"name":"Journal of virological methods","volume":"329 ","pages":"Article 114985"},"PeriodicalIF":2.2000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0166093424001095/pdfft?md5=7756697c86cc5a4478e13a15985801aa&pid=1-s2.0-S0166093424001095-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of virological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0166093424001095","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
The STARlet All-In-One system is a modular platform that integrates the complete molecular diagnostic workflow from nucleic acid extraction of clinical samples to PCR set-up and amplification. The platform was evaluated in comparison with laboratory developed tests (LDT) on fecal samples from patients with suspected viral gastro-enteritis. In a retrospective study, 72 positive samples were analysed, including all pathogens detected by the Seegene Allplex™ GI-virus assay, adenovirus, astrovirus, norovirus GI and GII, sapovirus, and rotavirus. Concordant results were obtained for 69 samples (96 %). Three discordant results were observed, one norovirus GII positive that gave an invalid result in the AIOS and two samples that were negative in the AIOS. One adenovirus positive that was subtyped as a genotype 2 virus, which is not associated with gastro-enteritis, and a sapovirus. In the prospective part of the study, 661 fecal samples were included. A total of 61 positive samples were detected, of which 60 were also detected by the AIOS. One norovirus GII positive sample (CT 35.2) was tested negative in the AIOS. Two additional sapovirus positive samples, CT 37 and 38, were detected by the AIOS but not by the LDT. The STARlet All-In-One platforms results in an automated molecular workflow with reduced hands-on time and enables running assays during out of office hours. Application of the Seegene Allplex™ GI-virus assay showed excellent concordance to the current diagnostic LDT. In a prospective comparison, only three discordant results were observed, all with CT values over 35 and therefore unlikely of clinical relevance.
期刊介绍:
The Journal of Virological Methods focuses on original, high quality research papers that describe novel and comprehensively tested methods which enhance human, animal, plant, bacterial or environmental virology and prions research and discovery.
The methods may include, but not limited to, the study of:
Viral components and morphology-
Virus isolation, propagation and development of viral vectors-
Viral pathogenesis, oncogenesis, vaccines and antivirals-
Virus replication, host-pathogen interactions and responses-
Virus transmission, prevention, control and treatment-
Viral metagenomics and virome-
Virus ecology, adaption and evolution-
Applied virology such as nanotechnology-
Viral diagnosis with novelty and comprehensive evaluation.
We seek articles, systematic reviews, meta-analyses and laboratory protocols that include comprehensive technical details with statistical confirmations that provide validations against current best practice, international standards or quality assurance programs and which advance knowledge in virology leading to improved medical, veterinary or agricultural practices and management.