Semaglutide and health risk: Development and validation of a LC-HRMS method for testing semaglutide in whole blood and application to real cases

IF 2.8 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Journal of Chromatography B Pub Date : 2024-06-14 DOI:10.1016/j.jchromb.2024.124187
N. Arbouche , A. Blanchot , J.S. Raul , P. Kintz
{"title":"Semaglutide and health risk: Development and validation of a LC-HRMS method for testing semaglutide in whole blood and application to real cases","authors":"N. Arbouche ,&nbsp;A. Blanchot ,&nbsp;J.S. Raul ,&nbsp;P. Kintz","doi":"10.1016/j.jchromb.2024.124187","DOIUrl":null,"url":null,"abstract":"<div><p>The use of semaglutide, also known by its trade name Ozempic®, has been increasing worldwide in recent years due to its benefits in treating type II diabetes. Thanks to its effects on appetite regulation, in many countries it is also used to treat obesity. However, due to its promotion by social media and celebrities as a weight-loss treatment, semaglutide is misused by a non-diabetic and non-obese population and by a young public, which is the main target of these media. Following the alert by the ANSM (Agence nationale de sécurité du médicament) in France and the FDA (Food and Drug Administration) in the United States, which imposed the addition of fatal effects to the list of side effects, the misuse of semaglutide seems to be becoming a public health problem. For this reason, it seems important that a toxicology laboratory has the capacity to test for semaglutide in blood.</p><p>In this study, the authors have developed and validated a method for the identification and quantification of semaglutide in whole blood using a LC-HRMS.</p><p>After the addition of the internal standard (bovine insulin), the blood was subjected to protein precipitation using a mix of acetonitrile/methanol (70:30,v:v). The validation procedure demonstrated an acceptable linearity between 2 and 500 ng/mL. LOD and LOQ were 1 and 2 ng/mL, respectively. Intra and inter-day precision were below 20 % at three concentrations. The method was successfully applied to the blood samples of 3 diabetic patients under treatment of semaglutide. The samples tested positive with concentrations ranging from 31 to 70 ng/mL which fall within the limits of therapeutic blood concentrations described in the literature.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S157002322400196X","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The use of semaglutide, also known by its trade name Ozempic®, has been increasing worldwide in recent years due to its benefits in treating type II diabetes. Thanks to its effects on appetite regulation, in many countries it is also used to treat obesity. However, due to its promotion by social media and celebrities as a weight-loss treatment, semaglutide is misused by a non-diabetic and non-obese population and by a young public, which is the main target of these media. Following the alert by the ANSM (Agence nationale de sécurité du médicament) in France and the FDA (Food and Drug Administration) in the United States, which imposed the addition of fatal effects to the list of side effects, the misuse of semaglutide seems to be becoming a public health problem. For this reason, it seems important that a toxicology laboratory has the capacity to test for semaglutide in blood.

In this study, the authors have developed and validated a method for the identification and quantification of semaglutide in whole blood using a LC-HRMS.

After the addition of the internal standard (bovine insulin), the blood was subjected to protein precipitation using a mix of acetonitrile/methanol (70:30,v:v). The validation procedure demonstrated an acceptable linearity between 2 and 500 ng/mL. LOD and LOQ were 1 and 2 ng/mL, respectively. Intra and inter-day precision were below 20 % at three concentrations. The method was successfully applied to the blood samples of 3 diabetic patients under treatment of semaglutide. The samples tested positive with concentrations ranging from 31 to 70 ng/mL which fall within the limits of therapeutic blood concentrations described in the literature.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
塞马鲁肽与健康风险:用于检测全血中塞马鲁肽的 LC-HRMS 方法的开发和验证以及在实际案例中的应用
塞马鲁肽(商品名 Ozempic®)因其在治疗 II 型糖尿病方面的优势,近年来在全球范围内的使用量不断增加。由于其对食欲的调节作用,在许多国家,它还被用于治疗肥胖症。然而,由于社交媒体和名人将其作为减肥治疗药物进行宣传,塞马鲁肽被非糖尿病和非肥胖人群以及年轻人误用,而年轻人正是这些媒体的主要宣传对象。法国国家药品安全局(ANSM)和美国食品和药物管理局(FDA)发出警告,在副作用清单中增加了致命影响,在此之后,误用塞马鲁肽似乎正在成为一个公共卫生问题。因此,毒理学实验室必须具备检测血液中塞马鲁肽的能力。在本研究中,作者开发并验证了一种使用 LC-HRMS 对全血中的塞马鲁肽进行鉴定和定量的方法。加入内标(牛胰岛素)后,使用乙腈/甲醇(70:30,v:v)混合液对血液进行蛋白沉淀。验证程序显示在 2 至 500 ng/mL 之间具有可接受的线性。LOD 和 LOQ 分别为 1 和 2 ng/mL。三个浓度的日内和日间精密度均低于20%。该方法成功地应用于 3 名正在接受塞马鲁肽治疗的糖尿病患者的血液样本。样本检测结果呈阳性,浓度范围为31至70纳克/毫升,均在文献所述的治疗血药浓度范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Chromatography B
Journal of Chromatography B 医学-分析化学
CiteScore
5.60
自引率
3.30%
发文量
306
审稿时长
44 days
期刊介绍: The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis. Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches. Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.
期刊最新文献
Development and application of UPLC-Q-Orbitrap HRMS methods for the determination of eight metabolites of p-chloronitrobenzene in human urine Simultaneous determination of total homocysteine, methionine, methylmalonic acid and 2-methylcitric acid in dried blood spots by ultra-performance liquid chromatography–tandem mass spectrometry Optimized isolation and purification of Shaoyao Gancao decoction using macroporous resin Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samples. Identification and characterization of GSK-9089 metabolites through high resolution-mass spectrometry based in vitro and in vivo rat biological sample analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1