Comparison of Lateral-flow Nanoparticle Fluorescence Assay and ELISA Method for Interferon-y Release Assay Test

Tandry Meriyanti, Maroloan Aruan, Diana Intan Lusiana Gabriella, Justina Andrea Renjaan
{"title":"Comparison of Lateral-flow Nanoparticle Fluorescence Assay and ELISA Method for Interferon-y Release Assay Test","authors":"Tandry Meriyanti, Maroloan Aruan, Diana Intan Lusiana Gabriella, Justina Andrea Renjaan","doi":"10.24293/ijcpml.v30i3.2212","DOIUrl":null,"url":null,"abstract":"The detection of latent tuberculosis (TB) infection to prevent progression to active TB disease is an essential part of the WHO's end-TB strategy. Diagnosis of latent TB infection is based on detecting immune responses to Mycobacterium tuberculosis antigens. Interferon Gamma Release Assays (IGRA) are superior to Tuberculin Skin Tests (TST) for detecting latent infection; however, the performance of IGRA is limited in resource-limited settings. This study evaluated the sensitivity, specificity, and agreement of the lateral-flow nanoparticle fluorescence assay (QIAreach QFT) compared with the ELISA method (QFT-Plus) as a reference test. This cross-sectional study was carried out in the laboratory department of Siloam Hospitals in Lippo Village, Banten, Indonesia, between January and June 2023. A total of 60 samples consisting of both males and females of all age groups were tested for QFT-Plus and were involved in the study using consecutive samples. Sensitivity, specificity, Negative Predictive Value (NPV), and Positive Predictive Value (PPV) of QIAreach QFT were 100% (95% CI 86.28-100), 70.96% (95% CI 51.96-85.78), 100%, (95% CI 84.56-100) and 73.53% (95% CI 55.64-87.12), respectively. The agreement calculation using Cohen's kappa coefficient, excluding indeterminate data, showed a kappa value 0.68 (95% CI 0.507-0.864). QIAreach QFT, with its superiority, could support the expansion of IGRA testing, particularly in remote areas, thereby helping the eradication attempt of TB infection.","PeriodicalId":354500,"journal":{"name":"Indonesian Journal of Clinical Pathology and Medical Laboratory","volume":"78 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Clinical Pathology and Medical Laboratory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24293/ijcpml.v30i3.2212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The detection of latent tuberculosis (TB) infection to prevent progression to active TB disease is an essential part of the WHO's end-TB strategy. Diagnosis of latent TB infection is based on detecting immune responses to Mycobacterium tuberculosis antigens. Interferon Gamma Release Assays (IGRA) are superior to Tuberculin Skin Tests (TST) for detecting latent infection; however, the performance of IGRA is limited in resource-limited settings. This study evaluated the sensitivity, specificity, and agreement of the lateral-flow nanoparticle fluorescence assay (QIAreach QFT) compared with the ELISA method (QFT-Plus) as a reference test. This cross-sectional study was carried out in the laboratory department of Siloam Hospitals in Lippo Village, Banten, Indonesia, between January and June 2023. A total of 60 samples consisting of both males and females of all age groups were tested for QFT-Plus and were involved in the study using consecutive samples. Sensitivity, specificity, Negative Predictive Value (NPV), and Positive Predictive Value (PPV) of QIAreach QFT were 100% (95% CI 86.28-100), 70.96% (95% CI 51.96-85.78), 100%, (95% CI 84.56-100) and 73.53% (95% CI 55.64-87.12), respectively. The agreement calculation using Cohen's kappa coefficient, excluding indeterminate data, showed a kappa value 0.68 (95% CI 0.507-0.864). QIAreach QFT, with its superiority, could support the expansion of IGRA testing, particularly in remote areas, thereby helping the eradication attempt of TB infection.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于干扰素 y 释放检测的侧流纳米粒子荧光测定法与酶联免疫吸附法的比较
检测潜伏肺结核(TB)感染以防止发展为活动性肺结核病是世界卫生组织终结结核病战略的重要组成部分。潜伏结核感染的诊断基于对结核分枝杆菌抗原免疫反应的检测。干扰素γ释放测定(IGRA)在检测潜伏感染方面优于结核菌素皮试(TST);然而,在资源有限的环境中,IGRA的效果有限。本研究评估了横向流纳米颗粒荧光测定法(QIAreach QFT)与作为参考检验的酶联免疫吸附法(QFT-Plus)相比的灵敏度、特异性和一致性。这项横断面研究于2023年1月至6月期间在印度尼西亚万丹省里波村的西乐庵医院实验室进行。共有 60 份不同年龄段的男性和女性样本接受了 QFT-Plus 检测,并使用连续样本参与了研究。QIAreach QFT的灵敏度、特异性、阴性预测值(NPV)和阳性预测值(PPV)分别为100%(95% CI 86.28-100)、70.96%(95% CI 51.96-85.78)、100%(95% CI 84.56-100)和73.53%(95% CI 55.64-87.12)。使用科恩卡帕系数(Cohen's kappa coefficient)计算的一致性(不包括不确定数据)显示,卡帕值为 0.68(95% CI 0.507-0.864)。QIAreach QFT 的优越性有助于扩大 IGRA 检测范围,尤其是在偏远地区,从而有助于根除结核病感染的努力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Lateral-flow Nanoparticle Fluorescence Assay and ELISA Method for Interferon-y Release Assay Test Correlation between VCAM-1 Level and Absolute Monocyte Count in Coronary Artery Disease Performance Evaluation of Semi-quantitative Urine Albumin Creatinine Ratio Using Meditape UC-11A Strip Test Risk Factors of Fungal Growth in Sputum Culture from Severe and Critical COVID-19 Patients Analysis of Albumin to Globulin Ratio as A Prognostic Predictor in Lupus Nephritis Patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1