{"title":"Pulmonary Vein Morphology in Patients Undergoing Catheter Ablation of Atrial Fibrillation.","authors":"Farkasová Barbora, Toman Ondřej, Pospíšil David, Míková Monika, Hejtmánková Nela, Zouharová Anna, Křikavová Lucie, Fiala Martin, Sepši Milan, Kala Petr, Novotný Tomáš","doi":"10.1007/s13239-024-00738-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Variations in the anatomy of pulmonary veins can influence selection of approaches of atrial fibrillation catheter ablation. Therefore, preprocedural evaluation and knowledge of pulmonary veins anatomy is crucial for proper mapping and the successful ablation of atrial fibrillation. The aim of this observational study was to assess CT angiography scans and perform detailed analysis of pulmonary veins morphology in patients scheduled for catheter ablation of atrial fibrillation.</p><p><strong>Methods: </strong>CT angiography was performed in 771 individuals (223 females, 548 males, mean age 58.4 ± 10.7 years). Pulmonary veins anatomy was evaluated using 3D models. The patterns used for evaluation included typical anatomy with four separate pulmonary veins, a common left ostium, and various types of accessory veins either alone or in combination with common left ostia.</p><p><strong>Results: </strong>An anatomical variant with common left ostium was observed as the most prevalent anatomy (44%). The typical variant was observed in 34.8% of patients. Accessory pulmonary veins were observed predominantly on the right side. The prevalence of anatomical variants did not differ between sexes with the exception of the unclassifiable category U (4.4% vs. 9%, p < 0.05).</p><p><strong>Conclusions: </strong>Our study shows that a considerable number of atypical anatomies is present in patients undergoing AF catheter ablation. This knowledge may influence the choice of instrumentation. The data could be possibly helpful also in development of new ablation techniques.</p>","PeriodicalId":54322,"journal":{"name":"Cardiovascular Engineering and Technology","volume":" ","pages":"616-622"},"PeriodicalIF":1.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s13239-024-00738-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Variations in the anatomy of pulmonary veins can influence selection of approaches of atrial fibrillation catheter ablation. Therefore, preprocedural evaluation and knowledge of pulmonary veins anatomy is crucial for proper mapping and the successful ablation of atrial fibrillation. The aim of this observational study was to assess CT angiography scans and perform detailed analysis of pulmonary veins morphology in patients scheduled for catheter ablation of atrial fibrillation.
Methods: CT angiography was performed in 771 individuals (223 females, 548 males, mean age 58.4 ± 10.7 years). Pulmonary veins anatomy was evaluated using 3D models. The patterns used for evaluation included typical anatomy with four separate pulmonary veins, a common left ostium, and various types of accessory veins either alone or in combination with common left ostia.
Results: An anatomical variant with common left ostium was observed as the most prevalent anatomy (44%). The typical variant was observed in 34.8% of patients. Accessory pulmonary veins were observed predominantly on the right side. The prevalence of anatomical variants did not differ between sexes with the exception of the unclassifiable category U (4.4% vs. 9%, p < 0.05).
Conclusions: Our study shows that a considerable number of atypical anatomies is present in patients undergoing AF catheter ablation. This knowledge may influence the choice of instrumentation. The data could be possibly helpful also in development of new ablation techniques.
期刊介绍:
Cardiovascular Engineering and Technology is a journal publishing the spectrum of basic to translational research in all aspects of cardiovascular physiology and medical treatment. It is the forum for academic and industrial investigators to disseminate research that utilizes engineering principles and methods to advance fundamental knowledge and technological solutions related to the cardiovascular system. Manuscripts spanning from subcellular to systems level topics are invited, including but not limited to implantable medical devices, hemodynamics and tissue biomechanics, functional imaging, surgical devices, electrophysiology, tissue engineering and regenerative medicine, diagnostic instruments, transport and delivery of biologics, and sensors. In addition to manuscripts describing the original publication of research, manuscripts reviewing developments in these topics or their state-of-art are also invited.