Evaluation of changes in lacrimal canaliculi width depending on temperature and viscosity of eye drops using spectral-domain optical coherence tomography in dogs.

IF 1.7 4区 农林科学 Q2 VETERINARY SCIENCES Veterinary ophthalmology Pub Date : 2024-06-20 DOI:10.1111/vop.13250
Hyeonu Sung, Seonmi Kang, Songhui Lee, Yeajin Jang, Giyeon Kim, Yujin Kim, Kangmoon Seo
{"title":"Evaluation of changes in lacrimal canaliculi width depending on temperature and viscosity of eye drops using spectral-domain optical coherence tomography in dogs.","authors":"Hyeonu Sung, Seonmi Kang, Songhui Lee, Yeajin Jang, Giyeon Kim, Yujin Kim, Kangmoon Seo","doi":"10.1111/vop.13250","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the changes in the width of the lower lacrimal canaliculi (LC) upon instillation of artificial tears (AT) at different temperatures and viscosities using spectral-domain optical coherence tomography (SD-OCT).</p><p><strong>Animal studied: </strong>Eight eyes of four client-owned adult dogs.</p><p><strong>Procedures: </strong>Imaging of lower LC was performed under general anesthesia. AT at temperatures of 2°C, 20°C, and 38°C, and a high-viscosity tear gel of 20°C, were topically instilled in 100 μL volumes. SD-OCT tracked LC width changes following each instillation.</p><p><strong>Results: </strong>The average baseline width of the LC was 96.38 ± 30.18 μm. The 2°C AT expanded LC width to 183.50 ± 44.11 μm, returning to baseline in 5.00 ± 1.31 min. The 20°C AT resulted in a width of 155.25 ± 35.79 μm, with a 3.88 ± 1.25 min return. The 38°C AT expanded LC width to 131.75 ± 29.49 μm, with a 2.25 ± 0.89 min return. The high-viscosity tear gel expanded LC width to 208.57 ± 56.31 μm, with remained expanded for 10 or more minutes. In temperature comparisons, the 2°C and 20°C AT significantly expanded the LC width more and had longer return times than the 38°C AT (p < .05). Viscosity comparisons showed higher viscosity eye drops significantly expanded LC width more than lower viscosity eye drops (p < .05).</p><p><strong>Conclusions: </strong>This study found that lower temperature and higher viscosity of eye drops had tendency to result in a wider expansion of the LC width. Additionally, the return time to baseline for LC width tended to be longer with eye drops of lower temperature and higher viscosity. This finding could be helpful in advancing future research on tear dynamics.</p>","PeriodicalId":23836,"journal":{"name":"Veterinary ophthalmology","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary ophthalmology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vop.13250","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the changes in the width of the lower lacrimal canaliculi (LC) upon instillation of artificial tears (AT) at different temperatures and viscosities using spectral-domain optical coherence tomography (SD-OCT).

Animal studied: Eight eyes of four client-owned adult dogs.

Procedures: Imaging of lower LC was performed under general anesthesia. AT at temperatures of 2°C, 20°C, and 38°C, and a high-viscosity tear gel of 20°C, were topically instilled in 100 μL volumes. SD-OCT tracked LC width changes following each instillation.

Results: The average baseline width of the LC was 96.38 ± 30.18 μm. The 2°C AT expanded LC width to 183.50 ± 44.11 μm, returning to baseline in 5.00 ± 1.31 min. The 20°C AT resulted in a width of 155.25 ± 35.79 μm, with a 3.88 ± 1.25 min return. The 38°C AT expanded LC width to 131.75 ± 29.49 μm, with a 2.25 ± 0.89 min return. The high-viscosity tear gel expanded LC width to 208.57 ± 56.31 μm, with remained expanded for 10 or more minutes. In temperature comparisons, the 2°C and 20°C AT significantly expanded the LC width more and had longer return times than the 38°C AT (p < .05). Viscosity comparisons showed higher viscosity eye drops significantly expanded LC width more than lower viscosity eye drops (p < .05).

Conclusions: This study found that lower temperature and higher viscosity of eye drops had tendency to result in a wider expansion of the LC width. Additionally, the return time to baseline for LC width tended to be longer with eye drops of lower temperature and higher viscosity. This finding could be helpful in advancing future research on tear dynamics.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用光谱域光学相干断层扫描评估狗泪管宽度随滴眼液温度和粘度的变化。
目的使用光谱域光学相干断层扫描(SD-OCT)评估在不同温度和粘度下注入人工泪液(AT)时下泪道(LC)宽度的变化:研究动物:四只客户饲养的成年犬的八只眼睛:程序:在全身麻醉的情况下对低密度脂蛋白胆固醇进行成像。将温度分别为 2°C、20°C 和 38°C 的 AT 和温度为 20°C 的高粘度泪液凝胶以 100 μL 的容量进行局部灌注。每次灌注后,SD-OCT 跟踪 LC 宽度的变化:LC 的平均基线宽度为 96.38 ± 30.18 μm。2°C AT 将 LC 宽度扩大到 183.50 ± 44.11 μm,在 5.00 ± 1.31 分钟内恢复到基线。20°C AT 使 LC 宽度为 155.25 ± 35.79 μm,恢复时间为 3.88 ± 1.25 分钟。38°C AT 将 LC 宽度扩大到 131.75 ± 29.49 μm,恢复时间为 2.25 ± 0.89 分钟。高粘度泪液凝胶将 LC 宽度扩展到 208.57 ± 56.31 μm,并保持扩展 10 分钟或更长时间。在温度比较中,与 38°C AT 相比,2°C 和 20°C AT 的 LC 宽度明显扩大得更多,回流时间也更长(p 结论):本研究发现,温度较低和粘度较高的眼药水往往会导致 LC 宽度扩大。此外,温度越低、粘度越高的眼药水,LC 宽度恢复到基线的时间越长。这一发现有助于推动未来的泪液动力学研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Veterinary ophthalmology
Veterinary ophthalmology 农林科学-兽医学
CiteScore
2.70
自引率
37.50%
发文量
82
审稿时长
12-24 weeks
期刊介绍: Veterinary Ophthalmology is a peer-reviewed, international journal that welcomes submission of manuscripts directed towards academic researchers of veterinary ophthalmology, specialists and general practitioners with a strong ophthalmology interest. Articles include those relating to all aspects of: Clinical and investigational veterinary and comparative ophthalmology; Prospective and retrospective studies or reviews of naturally occurring ocular disease in veterinary species; Experimental models of both animal and human ocular disease in veterinary species; Anatomic studies of the animal eye; Physiological studies of the animal eye; Pharmacological studies of the animal eye.
期刊最新文献
Dexamethasone-Antibiotic Interactions in Canine Ocular Bacteria: In Vitro Susceptibility Changes in Common Corneal Infection Pathogens. Lateral Tarsorrhaphy and Fixation on the Orbital Ligament to Correct Macroblepharon in Dogs: 77 Palpebral Fissures. Attempted ablation of an orbital cyst in a dog with 1% polidocanol using fluoroscopy and contrast cystography. Veterinary ophthalmology-Ocular surgery. Clinical manifestations of Florida spot keratopathy in dogs and cats: One hundred cases (2021-2024).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1