{"title":"A 382nVrms 100GΩ@50Hz Active Electrode for Dry-Electrode EEG Recording.","authors":"Guanghua Qian, Yanxing Suo, Qiao Cai, Yong Lian, Yang Zhao","doi":"10.1109/TBCAS.2024.3417716","DOIUrl":null,"url":null,"abstract":"<p><p>This article describes a low noise and ultra-high input impedance active electrode (AE) interface chip for dry-electrode EEG recording. To compensate the input parasitic capacitance and the ESD leakage, power/ground/ESD bootstrapping is proposed. This design integrates chopping stabilization technique to suppress flicker noise of the amplifier which has never been tackled in previous bootstrapped AE design. Both on-chip and off-chip input routing is active shielded to minimize wire parasitic. Fabricated in a 0.18μm CMOS process, the AE core occupies about 0.056mm2 and draws 17.95μA from a 1.8V supply. The proposed AE achieves 100GΩ input impedance at 50Hz and over 1GΩ at 1kHz with a low input-referred noise of 382nVrms integrated from 0.5Hz to 70Hz. This design is the first 100GΩ@50Hz input impedance chopper stabilized AE compared to the state-of-the-art. Dry-electrode EEG recording capability of the proposed AE are verified on three types of experiments including spontaneous α-wave, event related potential and steady-state visual evoked potential.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBCAS.2024.3417716","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This article describes a low noise and ultra-high input impedance active electrode (AE) interface chip for dry-electrode EEG recording. To compensate the input parasitic capacitance and the ESD leakage, power/ground/ESD bootstrapping is proposed. This design integrates chopping stabilization technique to suppress flicker noise of the amplifier which has never been tackled in previous bootstrapped AE design. Both on-chip and off-chip input routing is active shielded to minimize wire parasitic. Fabricated in a 0.18μm CMOS process, the AE core occupies about 0.056mm2 and draws 17.95μA from a 1.8V supply. The proposed AE achieves 100GΩ input impedance at 50Hz and over 1GΩ at 1kHz with a low input-referred noise of 382nVrms integrated from 0.5Hz to 70Hz. This design is the first 100GΩ@50Hz input impedance chopper stabilized AE compared to the state-of-the-art. Dry-electrode EEG recording capability of the proposed AE are verified on three types of experiments including spontaneous α-wave, event related potential and steady-state visual evoked potential.