Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement - an in vitro study.

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Oral and Maxillofacial Surgery-Heidelberg Pub Date : 2024-12-01 Epub Date: 2024-06-25 DOI:10.1007/s10006-024-01269-4
Florian Sebastian Reiff, Charlotte Bischoff, Henriette Woelfler, Stefan Roehling
{"title":"Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement - an in vitro study.","authors":"Florian Sebastian Reiff, Charlotte Bischoff, Henriette Woelfler, Stefan Roehling","doi":"10.1007/s10006-024-01269-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate whether inexperienced users applying a static navigation system can perform in-vitro a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians.</p><p><strong>Methods: </strong>Based on 36 identical resin models, a computer-assisted implant planning was performed and a surgical guide was produced accordingly. Three study groups were composed with 12 operators, each: control group with experienced surgeons (DOC), test group 1 with dental technicians (TEC) and test group 2 with non-specialists (OFC). Using a fully guided drilling protocol, two implants were placed into each of the 36 models. Subsequently, the differences between the virtually planned and final implant positions were determined and the transfer accuracy was evaluated.</p><p><strong>Results: </strong>For the control group DOC, the mean value of axial deviation was 1.90 ± 1.15 degrees, for 3-dimensional deviation at the implant base 0.52 ± 0.33 mm, for 3-dimensional deviation at the implant tip 0.76 ± 0.39 mm and for vertical deviation at the implant tip - 0.11 ± 0.51 mm. For corresponding parameters, the mean values of test group TEC were 1.99 ± 0.87 degrees, 0.42 ± 0.21 mm, 0.68 ± 0.30 mm and - 0.03 ± 0.33 mm and for test group OFC 2.29 ± 1.17 degrees, 0.63 ± 0.35 mm, 0.89 ± 0.43 mm and - 0.24 ± 0.57 mm, respectively. The results did not reveal any statistically significant differences between the control and the 2 test groups (p˃0.05).</p><p><strong>Conclusion: </strong>The results of the present in-vitro study demonstrated that inexperienced users applying a static navigation system can perform a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians in this specific in vitro setup.</p>","PeriodicalId":47251,"journal":{"name":"Oral and Maxillofacial Surgery-Heidelberg","volume":" ","pages":"1491-1500"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11480191/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral and Maxillofacial Surgery-Heidelberg","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10006-024-01269-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate whether inexperienced users applying a static navigation system can perform in-vitro a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians.

Methods: Based on 36 identical resin models, a computer-assisted implant planning was performed and a surgical guide was produced accordingly. Three study groups were composed with 12 operators, each: control group with experienced surgeons (DOC), test group 1 with dental technicians (TEC) and test group 2 with non-specialists (OFC). Using a fully guided drilling protocol, two implants were placed into each of the 36 models. Subsequently, the differences between the virtually planned and final implant positions were determined and the transfer accuracy was evaluated.

Results: For the control group DOC, the mean value of axial deviation was 1.90 ± 1.15 degrees, for 3-dimensional deviation at the implant base 0.52 ± 0.33 mm, for 3-dimensional deviation at the implant tip 0.76 ± 0.39 mm and for vertical deviation at the implant tip - 0.11 ± 0.51 mm. For corresponding parameters, the mean values of test group TEC were 1.99 ± 0.87 degrees, 0.42 ± 0.21 mm, 0.68 ± 0.30 mm and - 0.03 ± 0.33 mm and for test group OFC 2.29 ± 1.17 degrees, 0.63 ± 0.35 mm, 0.89 ± 0.43 mm and - 0.24 ± 0.57 mm, respectively. The results did not reveal any statistically significant differences between the control and the 2 test groups (p˃0.05).

Conclusion: The results of the present in-vitro study demonstrated that inexperienced users applying a static navigation system can perform a fully guided implant placement protocol and achieve similar results in terms of accuracy compared to experienced clinicians in this specific in vitro setup.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
临床专业知识和实践经验对引导下种植牙转移准确性的影响--一项体外研究。
目的:研究应用静态导航系统的无经验用户能否在体外执行完全引导的种植体植入方案,并在准确性方面与有经验的临床医生取得相似的结果:根据 36 个相同的树脂模型,进行计算机辅助种植规划,并制作相应的手术指南。三个研究组各有 12 名操作人员:对照组由经验丰富的外科医生(DOC)组成,测试组 1 由牙科技师(TEC)组成,测试组 2 由非专业人员(OFC)组成。采用完全引导钻孔方案,在 36 个模型中每个模型植入两个种植体。随后,确定了虚拟计划位置和最终种植体位置之间的差异,并评估了转移的准确性:对照组 DOC 的轴向偏差平均值为 1.90 ± 1.15 度,种植体基底的三维偏差平均值为 0.52 ± 0.33 毫米,种植体顶端的三维偏差平均值为 0.76 ± 0.39 毫米,种植体顶端的垂直偏差平均值为 0.11 ± 0.51 毫米。对于相应的参数,测试组 TEC 的平均值分别为 1.99 ± 0.87 度、0.42 ± 0.21 毫米、0.68 ± 0.30 毫米和 - 0.03 ± 0.33 毫米,测试组 OFC 的平均值分别为 2.29 ± 1.17 度、0.63 ± 0.35 毫米、0.89 ± 0.43 毫米和 - 0.24 ± 0.57 毫米。结果显示,对照组和 2 个测试组之间的差异无统计学意义(p˃0.05):本体外研究结果表明,在这种特定的体外设置中,应用静态导航系统的无经验用户可以执行完全引导的种植体植入方案,并在准确性方面与有经验的临床医师取得相似的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Oral and Maxillofacial Surgery-Heidelberg
Oral and Maxillofacial Surgery-Heidelberg DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.20
自引率
5.60%
发文量
118
期刊介绍: Oral & Maxillofacial Surgery founded as Mund-, Kiefer- und Gesichtschirurgie is a peer-reviewed online journal. It is designed for clinicians as well as researchers.The quarterly journal offers comprehensive coverage of new techniques, important developments and innovative ideas in oral and maxillofacial surgery and interdisciplinary aspects of cranial, facial and oral diseases and their management. The journal publishes papers of the highest scientific merit and widest possible scope on work in oral and maxillofacial surgery as well as supporting specialties. Practice-oriented articles help improve the methods used in oral and maxillofacial surgery.Every aspect of oral and maxillofacial surgery is fully covered through a range of invited review articles, clinical and research articles, technical notes, abstracts, and case reports. Specific topics are: aesthetic facial surgery, clinical pathology, computer-assisted surgery, congenital and craniofacial deformities, dentoalveolar surgery, head and neck oncology, implant dentistry, oral medicine, orthognathic surgery, reconstructive surgery, skull base surgery, TMJ and trauma.Time-limited reviewing and electronic processing allow to publish articles as fast as possible. Accepted articles are rapidly accessible online.Clinical studies submitted for publication have to include a declaration that they have been approved by an ethical committee according to the World Medical Association Declaration of Helsinki 1964 (last amendment during the 52nd World Medical Association General Assembly, Edinburgh, Scotland, October 2000). Experimental animal studies have to be carried out according to the principles of laboratory animal care (NIH publication No 86-23, revised 1985).
期刊最新文献
Correction to: Mapping trends in preemptive analgesia related to oral surgery with the use of Ibuprofen: a comprehensive quantitative and qualitative analysis of bibliometric parameters. Correction to: Acute orbital compartment syndrome due to traumatic hemorrhage: 4-year case series and relevant literature review with emphasis on its management. Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement - an in vitro study. Clinical results of two different three-dimensional plate types for the treatment of mandibular angle fractures: a retrospective analysis. Clinicopathologic and imaging features of odontogenic myxomas: a multi-institutional study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1