Characterization of silicon pore optics for the NewAthena X-ray observatory in the PTB laboratory at BESSY II.

IF 2.5 3区 物理与天体物理 Journal of Synchrotron Radiation Pub Date : 2024-07-01 Epub Date: 2024-06-24 DOI:10.1107/S1600577524004090
M Krumrey, D Skroblin, L Cibik, M Collon, G Vacanti, N Barrière, E Hauser, M Bavdaz
{"title":"Characterization of silicon pore optics for the NewAthena X-ray observatory in the PTB laboratory at BESSY II.","authors":"M Krumrey, D Skroblin, L Cibik, M Collon, G Vacanti, N Barrière, E Hauser, M Bavdaz","doi":"10.1107/S1600577524004090","DOIUrl":null,"url":null,"abstract":"<p><p>The New Advanced Telescope for High ENergy Astrophysics (NewAthena) will be the largest space-based X-ray observatory ever built. It will have an effective area above 1.1 m<sup>2</sup> at 1 keV, which corresponds to a polished mirror surface of about 300 m<sup>2</sup> due to the grazing incidence. As such a mirror area is not achievable with an acceptable mass even with nested shells, silicon pore optics (SPO) technology will be utilized. In the PTB laboratory at BESSY II, two dedicated beamlines are in use for their characterization with monochromatic radiation at 1 keV and a low divergence well below 2 arcsec: the X-ray Pencil Beam Facility (XPBF 1) and the X-ray Parallel Beam Facility (XPBF 2.0), where beam sizes up to 8 mm × 8 mm are available while maintaining low beam divergence. This beamline is used for characterizing mirror stacks and controlling the focusing properties of mirror modules (MMs) - consisting of four mirror stacks - during their assembly at the beamline. A movable CCD based camera system 12 m from the MM registers the direct and the reflected beams. The positioning of the detector is verified by a laser tracker. The energy-dependent reflectance in double reflection through the pores of an MM with an Ir coating was measured at the PTB four-crystal monochromator beamline in the photon energy range 1.75 keV to 10 keV, revealing the effects of the Ir M edges. The measured reflectance properties are in agreement with the design values to achieve the envisaged effective area.</p>","PeriodicalId":48729,"journal":{"name":"Journal of Synchrotron Radiation","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11226178/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Synchrotron Radiation","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1107/S1600577524004090","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The New Advanced Telescope for High ENergy Astrophysics (NewAthena) will be the largest space-based X-ray observatory ever built. It will have an effective area above 1.1 m2 at 1 keV, which corresponds to a polished mirror surface of about 300 m2 due to the grazing incidence. As such a mirror area is not achievable with an acceptable mass even with nested shells, silicon pore optics (SPO) technology will be utilized. In the PTB laboratory at BESSY II, two dedicated beamlines are in use for their characterization with monochromatic radiation at 1 keV and a low divergence well below 2 arcsec: the X-ray Pencil Beam Facility (XPBF 1) and the X-ray Parallel Beam Facility (XPBF 2.0), where beam sizes up to 8 mm × 8 mm are available while maintaining low beam divergence. This beamline is used for characterizing mirror stacks and controlling the focusing properties of mirror modules (MMs) - consisting of four mirror stacks - during their assembly at the beamline. A movable CCD based camera system 12 m from the MM registers the direct and the reflected beams. The positioning of the detector is verified by a laser tracker. The energy-dependent reflectance in double reflection through the pores of an MM with an Ir coating was measured at the PTB four-crystal monochromator beamline in the photon energy range 1.75 keV to 10 keV, revealing the effects of the Ir M edges. The measured reflectance properties are in agreement with the design values to achieve the envisaged effective area.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在 BESSY II 的 PTB 实验室对用于 NewAthena X 射线观测台的硅孔隙光学器件进行鉴定。
新的高能天体物理学高级望远镜(NewAthena)将是有史以来最大的空间 X 射线观测站。它在 1 keV 时的有效面积将超过 1.1 平方米,由于掠入射,这相当于一个约 300 平方米的抛光镜面。由于即使采用嵌套式外壳,也无法在可接受的质量范围内实现这样的镜面面积,因此将采用硅孔光学(SPO)技术。在 BESSY II 的 PTB 实验室中,有两条专门的光束线用于用 1 keV 的单色辐射和远小于 2 弧秒的低发散对它们进行鉴定:X 射线铅笔光束设施(XPBF 1)和 X 射线平行光束设施(XPBF 2.0),在这两条光束线中,光束尺寸可达 8 毫米 × 8 毫米,同时保持低光束发散。该光束线用于鉴定镜组,并控制由四个镜组组成的镜组模块(MMs)在光束线组装时的聚焦特性。一个基于 CCD 的可移动照相系统在距离 MM 12 米处记录直射和反射光束。探测器的定位由激光跟踪器进行验证。在 PTB 四晶体单色仪光束线上,测量了在 1.75 keV 至 10 keV 的光子能量范围内,通过带有 Ir 涂层的 MM 孔隙的双反射中与能量相关的反射率,揭示了 Ir M 边缘的影响。测得的反射特性与设计值一致,达到了预期的有效面积。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Synchrotron Radiation
Journal of Synchrotron Radiation INSTRUMENTS & INSTRUMENTATIONOPTICS&-OPTICS
CiteScore
5.60
自引率
12.00%
发文量
289
审稿时长
1 months
期刊介绍: Synchrotron radiation research is rapidly expanding with many new sources of radiation being created globally. Synchrotron radiation plays a leading role in pure science and in emerging technologies. The Journal of Synchrotron Radiation provides comprehensive coverage of the entire field of synchrotron radiation and free-electron laser research including instrumentation, theory, computing and scientific applications in areas such as biology, nanoscience and materials science. Rapid publication ensures an up-to-date information resource for scientists and engineers in the field.
期刊最新文献
BEATS: BEAmline for synchrotron X-ray microTomography at SESAME. Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source. High-angular-sensitivity X-ray phase-contrast microtomography of soft tissue through a two-directional beam-tracking synchrotron set-up. In situ photodeposition of ultra-small palladium particles on TiO2. StreamSAXS: a Python-based workflow platform for processing streaming SAXS/WAXS data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1