Reading of gafchromic EBT-3 film using an overhead scanner.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Biomedical Physics & Engineering Express Pub Date : 2024-07-09 DOI:10.1088/2057-1976/ad5cf8
H Bantan, H Yasuda
{"title":"Reading of gafchromic EBT-3 film using an overhead scanner.","authors":"H Bantan, H Yasuda","doi":"10.1088/2057-1976/ad5cf8","DOIUrl":null,"url":null,"abstract":"<p><p>Gafchromic film, a commercially available radiochromic film, has been developed and widely used as an effective tool for radiation dose verification and quality assurance in radiotherapy. However, the orientation effect in scanning a film remains a concern for practical application in beam profile monitoring. To resolve this issue, the authors introduced a novel method using an overhead scanner (OHS) coupled with a tracing light board instead of a conventional flatbed scanner (FBS) to read Gafchromic EBT3 films. We investigated the orientation effect of the EBT3 film with a regular hexagonal shape after irradiation with 5 Gy x-rays (160 kV, 6.3 mA) and compared the digitized images acquired using a commercially available OHS (CZUR Aura) and a conventional FBS (EPSON GT-X980). As a result, RGB color intensities acquired from the OHS showed significantly lower orientation effect of the color intensities of RGB components than those from FBS. This finding indicates the high potential of the proposed method for achieving more precise two-dimensional dosimetry. Further studies are required to confirm the effectiveness of this method under different irradiation conditions over a wider dose range.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/ad5cf8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Gafchromic film, a commercially available radiochromic film, has been developed and widely used as an effective tool for radiation dose verification and quality assurance in radiotherapy. However, the orientation effect in scanning a film remains a concern for practical application in beam profile monitoring. To resolve this issue, the authors introduced a novel method using an overhead scanner (OHS) coupled with a tracing light board instead of a conventional flatbed scanner (FBS) to read Gafchromic EBT3 films. We investigated the orientation effect of the EBT3 film with a regular hexagonal shape after irradiation with 5 Gy x-rays (160 kV, 6.3 mA) and compared the digitized images acquired using a commercially available OHS (CZUR Aura) and a conventional FBS (EPSON GT-X980). As a result, RGB color intensities acquired from the OHS showed significantly lower orientation effect of the color intensities of RGB components than those from FBS. This finding indicates the high potential of the proposed method for achieving more precise two-dimensional dosimetry. Further studies are required to confirm the effectiveness of this method under different irradiation conditions over a wider dose range.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用高架扫描仪读取 Gafchromic EBT-3 胶片。
Gafchromic 胶片是一种市场上可买到的放射性变色胶片,已被开发出来并广泛应用于放射治疗中的辐射剂量验证和质量保证。然而,在实际应用中,扫描胶片时的取向效应仍然是光束轮廓监测的一个令人担忧的问题。为了解决这个问题,作者采用了一种新方法,即使用高架扫描仪(OHS)和追踪灯板,而不是传统的平板扫描仪(FBS)来读取加富色EBT3胶片。我们研究了具有规则六边形的 EBT3 薄膜在 5 Gy X 射线(160 kV,6.3 mA)照射后的取向效应,并比较了使用市售高架扫描仪(Aura,CZUR)和传统平板扫描仪(GT-X980,EPSON)获取的数字化图像。结果显示,从 OHS 采集的 RGB 色彩强度对 RGB 成分色彩强度的定向影响明显低于从 FBS 采集的 RGB 色彩强度。这一结果表明,建议的方法在实现更精确的二维剂量测定方面具有很大的潜力。还需要进一步的研究来证实这种方法在更大剂量范围内不同辐照条件下的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
期刊最新文献
Innovative 3D bioprinting approaches for advancing brain science and medicine: a literature review. Assessing Anticancer Properties of PEGylated Platinum Nanoparticles on Human Breast Cancer Cell lines using in-vitro Assays. Prediction of directional solidification in freeze casting of biomaterial scaffolds using physics-informed neural networks. Synthetic CT generation from CBCT based on structural constraint cycle-EEM-GAN Detection of Invasive Ductal Carcinoma by Electrical Impedance Spectroscopy Implementing Gaussian Relaxation-Time Distribution (EIS-GRTD).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1