Inflammation assessment and therapeutic monitoring based on highly sensitive and multi-level electrochemical detection of PGE2

IF 10.7 1区 生物学 Q1 BIOPHYSICS Biosensors and Bioelectronics Pub Date : 2024-06-28 DOI:10.1016/j.bios.2024.116539
Tingting Zhang, Congcong Zhang, Xue Li, Dongfang Ren, Mingshuang Zheng, Shuo Zhang, Fangping Yuan, Xin Du, Zhenguo Zhang
{"title":"Inflammation assessment and therapeutic monitoring based on highly sensitive and multi-level electrochemical detection of PGE2","authors":"Tingting Zhang,&nbsp;Congcong Zhang,&nbsp;Xue Li,&nbsp;Dongfang Ren,&nbsp;Mingshuang Zheng,&nbsp;Shuo Zhang,&nbsp;Fangping Yuan,&nbsp;Xin Du,&nbsp;Zhenguo Zhang","doi":"10.1016/j.bios.2024.116539","DOIUrl":null,"url":null,"abstract":"<div><p>Prostaglandin E2 (PGE2), an eicosane, regulates the physiological activity of inflammatory cells and represents a potential therapeutic target for facilitating tissue repair in vivo. In our work, an electrochemical immunosensor employing Ketjen black-Au nanoparticles (KB–Au) and poly tannic acid nanospheres conjugated with anti-PGE2 polyclonal antibody (PTAN-Ab) was designed to ultra-sensitively analyze PGE2 levels secreted by living cells and tissues. Antibody assembly strategies were explored to achieve signal amplification. Moreover, we studied the therapy effects of docosahexaenoic acid (DHA), arachidonic acid (AA), hyaluronic acid (HA), and small molecule 15-hydroxyprostaglandin dehydrogenase inhibitor (SW033291) on inflammation and evaluated the protective functions of HA and SW033291 in a murine model subjected to colitis induced by dextran sulfate sodium (DSS) using the developed sensor. The sensor exhibited a linear range of 10<sup>−5</sup>–10<sup>6</sup> fg/mL and a detection limit (LOD) of 10<sup>−5</sup> fg/mL. Fetal bovine serum (FBS) samples were used to achieve high recovery of target analytes. This study not only presents an effective strategy for ultra-sensitively monitoring PGE2 but also provides valuable insights into assessing the degree of inflammation and the therapeutic effect of related drugs. Research on human health monitoring and regenerative medicine could greatly benefit from the findings.</p></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":null,"pages":null},"PeriodicalIF":10.7000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S095656632400544X","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Prostaglandin E2 (PGE2), an eicosane, regulates the physiological activity of inflammatory cells and represents a potential therapeutic target for facilitating tissue repair in vivo. In our work, an electrochemical immunosensor employing Ketjen black-Au nanoparticles (KB–Au) and poly tannic acid nanospheres conjugated with anti-PGE2 polyclonal antibody (PTAN-Ab) was designed to ultra-sensitively analyze PGE2 levels secreted by living cells and tissues. Antibody assembly strategies were explored to achieve signal amplification. Moreover, we studied the therapy effects of docosahexaenoic acid (DHA), arachidonic acid (AA), hyaluronic acid (HA), and small molecule 15-hydroxyprostaglandin dehydrogenase inhibitor (SW033291) on inflammation and evaluated the protective functions of HA and SW033291 in a murine model subjected to colitis induced by dextran sulfate sodium (DSS) using the developed sensor. The sensor exhibited a linear range of 10−5–106 fg/mL and a detection limit (LOD) of 10−5 fg/mL. Fetal bovine serum (FBS) samples were used to achieve high recovery of target analytes. This study not only presents an effective strategy for ultra-sensitively monitoring PGE2 but also provides valuable insights into assessing the degree of inflammation and the therapeutic effect of related drugs. Research on human health monitoring and regenerative medicine could greatly benefit from the findings.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于高灵敏度和多层次 PGE2 电化学检测的炎症评估和治疗监测。
前列腺素 E2(PGE2)是一种二十烷,可调节炎症细胞的生理活动,是促进体内组织修复的潜在治疗靶点。在我们的工作中,我们设计了一种电化学免疫传感器,采用了与抗 PGE2 多克隆抗体(PTAN-Ab)连接的 Ketjen 黑金纳米粒子(KB-Au)和聚单宁酸纳米球,以超灵敏地分析活细胞和组织分泌的 PGE2 水平。我们探索了抗体组装策略,以实现信号放大。此外,我们还研究了二十二碳六烯酸(DHA)、花生四烯酸(AA)、透明质酸(HA)和小分子 15-羟基前列腺素脱氢酶抑制剂(SW033291)对炎症的治疗作用,并利用所开发的传感器在右旋糖酐硫酸钠(DSS)诱导的小鼠结肠炎模型中评估了 HA 和 SW033291 的保护功能。该传感器的线性范围为 10-5-106 fg/mL,检测限 (LOD) 为 10-5 fg/mL。使用胎牛血清(FBS)样品实现了目标分析物的高回收率。这项研究不仅提出了超灵敏监测 PGE2 的有效策略,还为评估炎症程度和相关药物的治疗效果提供了宝贵的见解。人类健康监测和再生医学研究将从这些发现中受益匪浅。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biosensors and Bioelectronics
Biosensors and Bioelectronics 工程技术-电化学
CiteScore
20.80
自引率
7.10%
发文量
1006
审稿时长
29 days
期刊介绍: Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.
期刊最新文献
A novel platform for mutation detection in colorectal cancer using a PNA-LNA molecular switch Enzyme-accelerated catalytic DNA circuits enable rapid and one-pot detection of bacterial pathogens. A novel cleanroom-free technique for simultaneous electrodeposition of polypyrrole onto array of IDuEs: Towards low-cost, stable and accurate point-of-care TBI diagnosis without trained manpower. In situ surface-enhanced Raman spectroscopy for membrane protein analysis and sensing. Electrochemical cytosensors for non-invasive liquid biopsy: Detection procedures and technologies for circulating tumor cells
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1