Evaluation of Solubility, and Volumetric and Morphological Alterations of Bioceramic Filling Material for Primary Teeth: A New Methodological Approach.

IF 1.9 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Dentistry Pub Date : 2024-06-24 eCollection Date: 2024-01-01 DOI:10.1155/2024/5945033
Víctor M Ochoa-Rodríguez, Hernán Coaguila-Llerena, Leandro Fernandes, Ana B B Solcia, Juliane M Guerreiro-Tanomaru, Mário Tanomaru-Filho, Gisele Faria
{"title":"Evaluation of Solubility, and Volumetric and Morphological Alterations of Bioceramic Filling Material for Primary Teeth: A New Methodological Approach.","authors":"Víctor M Ochoa-Rodríguez, Hernán Coaguila-Llerena, Leandro Fernandes, Ana B B Solcia, Juliane M Guerreiro-Tanomaru, Mário Tanomaru-Filho, Gisele Faria","doi":"10.1155/2024/5945033","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the solubility and the volumetric and morphological alterations of bioceramic filling material (Bio-CP) for primary teeth.</p><p><strong>Materials and methods: </strong>Bio-CP, Calen thickened with zinc oxide (Calen-ZO), and with zinc oxide eugenol (ZOE) were placed in 1- or 2-mm-diameter polyethylene tubes and immersed in water or phosphate-buffered saline (PBS) for 30 days. The solubility (mass loss) was assessed using methodology modified from ISO 6876. Filling capacity, volumetric changes, and presence of voids were assessed by microcomputed tomography (micro-CT). The surface distribution of the chemical elements and the crystalline phases was evaluated by energy scattering X-ray scanning electron microscopy (SEM-EDX) and X-ray diffraction (XRD) to detect hydroxyapatite precipitate and components. The Shapiro-Wilk, Kruskal-Wallis, and Dunn's or two-way ANOVA and Tukey post hoc test were used (<i>α</i> = 0.05).</p><p><strong>Results: </strong>The solubility was ZOE > Calen-ZO = Bio-CP. Calen-ZO and Bio-CP were more soluble in water than in PBS. All the materials showed greater solubility in 2-mm tube diameter in both PBS and distilled water, except for Bio-CP in distilled water, which showed no difference between both tube diameters (1 and 2 mm). Only Calen-ZO and ZOE were analyzed by micro-CT, because Bio-CP separated into two phases during scanning. Calen-ZO had greater volumetric loss and presence of voids than ZOE in water, but there was no difference in PBS. The hydroxyapatite precipitate on the surface of Bio-CP and Calen-ZO was detected after immersion in PBS.</p><p><strong>Conclusion: </strong>Although Bio-CP had acceptable solubility and filling capacity, its composition did not allow a proper volumetric and void assessment. From a clinical perspective, Bio-CP has the potential to become a suitable material for root canal filling in primary teeth. Nonetheless, its composition must first be revised to achieve better chemical stability prior to its recommendation.</p>","PeriodicalId":13947,"journal":{"name":"International Journal of Dentistry","volume":"2024 ","pages":"5945033"},"PeriodicalIF":1.9000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11217577/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/5945033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the solubility and the volumetric and morphological alterations of bioceramic filling material (Bio-CP) for primary teeth.

Materials and methods: Bio-CP, Calen thickened with zinc oxide (Calen-ZO), and with zinc oxide eugenol (ZOE) were placed in 1- or 2-mm-diameter polyethylene tubes and immersed in water or phosphate-buffered saline (PBS) for 30 days. The solubility (mass loss) was assessed using methodology modified from ISO 6876. Filling capacity, volumetric changes, and presence of voids were assessed by microcomputed tomography (micro-CT). The surface distribution of the chemical elements and the crystalline phases was evaluated by energy scattering X-ray scanning electron microscopy (SEM-EDX) and X-ray diffraction (XRD) to detect hydroxyapatite precipitate and components. The Shapiro-Wilk, Kruskal-Wallis, and Dunn's or two-way ANOVA and Tukey post hoc test were used (α = 0.05).

Results: The solubility was ZOE > Calen-ZO = Bio-CP. Calen-ZO and Bio-CP were more soluble in water than in PBS. All the materials showed greater solubility in 2-mm tube diameter in both PBS and distilled water, except for Bio-CP in distilled water, which showed no difference between both tube diameters (1 and 2 mm). Only Calen-ZO and ZOE were analyzed by micro-CT, because Bio-CP separated into two phases during scanning. Calen-ZO had greater volumetric loss and presence of voids than ZOE in water, but there was no difference in PBS. The hydroxyapatite precipitate on the surface of Bio-CP and Calen-ZO was detected after immersion in PBS.

Conclusion: Although Bio-CP had acceptable solubility and filling capacity, its composition did not allow a proper volumetric and void assessment. From a clinical perspective, Bio-CP has the potential to become a suitable material for root canal filling in primary teeth. Nonetheless, its composition must first be revised to achieve better chemical stability prior to its recommendation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估基牙生物陶瓷填充材料的溶解性、体积和形态变化:一种新的方法论。
目的评估用于基牙的生物陶瓷填充材料(Bio-CP)的溶解性、体积和形态变化:将 Bio-CP、氧化锌增稠的 Calen(Calen-ZO)和氧化锌丁香酚(ZOE)放入直径为 1 毫米或 2 毫米的聚乙烯管中,在水或磷酸盐缓冲盐水(PBS)中浸泡 30 天。溶解度(质量损失)采用 ISO 6876 中修改过的方法进行评估。填充能力、体积变化和空隙的存在通过微计算机断层扫描(micro-CT)进行评估。通过能量散射 X 射线扫描电子显微镜(SEM-EDX)和 X 射线衍射(XRD)评估了化学元素和结晶相的表面分布,以检测羟基磷灰石沉淀和成分。采用 Shapiro-Wilk、Kruskal-Wallis、Dunn's 或双向方差分析和 Tukey 后检验(α = 0.05):溶解度为 ZOE > Calen-ZO = Bio-CP。Calen-ZO 和 Bio-CP 在水中的溶解度高于在 PBS 中的溶解度。除了 Bio-CP 在蒸馏水中的溶解度在两种管径(1 毫米和 2 毫米)中没有差异外,所有材料在 2 毫米管径的 PBS 和蒸馏水中的溶解度都更大。只有 Calen-ZO 和 ZOE 通过显微 CT 进行了分析,因为 Bio-CP 在扫描过程中分成了两相。与 ZOE 相比,Calen-ZO 在水中的体积损失更大,空隙也更多,但在 PBS 中没有差异。将 Bio-CP 和 Calen-ZO 浸入 PBS 后,可在其表面检测到羟基磷灰石沉淀:结论:虽然 Bio-CP 的溶解度和填充能力可以接受,但其成分无法进行适当的体积和空隙评估。从临床角度来看,Bio-CP 有可能成为一种适用于基牙根管充填的材料。不过,在推荐使用之前,必须首先对其成分进行修改,以获得更好的化学稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Dentistry
International Journal of Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
4.80%
发文量
219
审稿时长
20 weeks
期刊最新文献
Enhancing pH Modulation and Calcium Ions Release in External Resorption Artificial Defects: A Comparative Analysis of Ultrasonic Activation Effects on Ca(OH)2, MTA, and CEM Cement. Understanding Parental Emotions: Children's Dental Visits and the Separation Experience. Prevalence and Severity of Sleep Bruxism in Edentulous Patients: A Cross-Sectional Study. Elementary Teacher's Perception of Oral Health Education in a City of the Brazilian Amazon: A Cross-Sectional Study. Comparison of Internal and Marginal Adaptation of Endocrowns at Different Depths Fabricated by the Digital and Conventional Impression Techniques: Internal and Marginal Fit of Endocrowns.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1