Incidence of anastomotic leakage using powered circular staplers versus manual circular staplers for left colorectal anastomosis: a cost-effectiveness analysis.
V Pla-Martí, J Martín-Arévalo, D Moro-Valdezate, S García-Botello, L Pérez-Santiago, I Barrachina-Martinez, S González-de-Julián, D Vivas-Consuelo, A Espí-Macías
{"title":"Incidence of anastomotic leakage using powered circular staplers versus manual circular staplers for left colorectal anastomosis: a cost-effectiveness analysis.","authors":"V Pla-Martí, J Martín-Arévalo, D Moro-Valdezate, S García-Botello, L Pérez-Santiago, I Barrachina-Martinez, S González-de-Julián, D Vivas-Consuelo, A Espí-Macías","doi":"10.1007/s10151-024-02936-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Colorectal anastomotic leakage causes severe consequences for patients and healthcare system as it will lead to increased consumption of hospital resources and costs. Technological improvements in anastomotic devices could reduce the incidence of leakage and its economic impact. The aim of the present study was to assess if the use of a new powered circular stapler is cost-effective.</p><p><strong>Method: </strong>This observational study included patients undergoing left-sided circular stapled colorectal anastomosis between January 2018 and December 2021. Propensity score matching was carried out to create two comparable groups depending on whether the anastomosis was performed using a manual or powered circular device. The rate of anastomotic leakage, its severity, the consumption of hospital resources, and its cost were the main outcome measures. A cost-effectiveness analysis comparing the powered circular stapler versus manual circular staplers was performed.</p><p><strong>Results: </strong>A total of 330 patients were included in the study, 165 in each group. Anastomotic leakage rates were significantly different (p = 0.012): 22 patients (13.3%) in the manual group versus 8 patients (4.8%) in the powered group. The effectiveness of the powered stapler and manual stapler was 98.27% and 93.69%, respectively. The average cost per patient in the powered group was €6238.38, compared with €9700.12 in the manual group. The incremental cost-effectiveness ratio was - €74,915.28 per patient without anastomotic complications.</p><p><strong>Conclusion: </strong>The incremental cost of powered circular stapler compared with manual devices was offset by the savings from lowered incidence and cost of management of anastomotic leaks.</p>","PeriodicalId":51192,"journal":{"name":"Techniques in Coloproctology","volume":"28 1","pages":"76"},"PeriodicalIF":2.7000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11219427/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Coloproctology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10151-024-02936-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Colorectal anastomotic leakage causes severe consequences for patients and healthcare system as it will lead to increased consumption of hospital resources and costs. Technological improvements in anastomotic devices could reduce the incidence of leakage and its economic impact. The aim of the present study was to assess if the use of a new powered circular stapler is cost-effective.
Method: This observational study included patients undergoing left-sided circular stapled colorectal anastomosis between January 2018 and December 2021. Propensity score matching was carried out to create two comparable groups depending on whether the anastomosis was performed using a manual or powered circular device. The rate of anastomotic leakage, its severity, the consumption of hospital resources, and its cost were the main outcome measures. A cost-effectiveness analysis comparing the powered circular stapler versus manual circular staplers was performed.
Results: A total of 330 patients were included in the study, 165 in each group. Anastomotic leakage rates were significantly different (p = 0.012): 22 patients (13.3%) in the manual group versus 8 patients (4.8%) in the powered group. The effectiveness of the powered stapler and manual stapler was 98.27% and 93.69%, respectively. The average cost per patient in the powered group was €6238.38, compared with €9700.12 in the manual group. The incremental cost-effectiveness ratio was - €74,915.28 per patient without anastomotic complications.
Conclusion: The incremental cost of powered circular stapler compared with manual devices was offset by the savings from lowered incidence and cost of management of anastomotic leaks.
期刊介绍:
Techniques in Coloproctology is an international journal fully devoted to diagnostic and operative procedures carried out in the management of colorectal diseases. Imaging, clinical physiology, laparoscopy, open abdominal surgery and proctoperineology are the main topics covered by the journal. Reviews, original articles, technical notes and short communications with many detailed illustrations render this publication indispensable for coloproctologists and related specialists. Both surgeons and gastroenterologists are represented on the distinguished Editorial Board, together with pathologists, radiologists and basic scientists from all over the world. The journal is strongly recommended to those who wish to be updated on recent developments in the field, and improve the standards of their work.
Manuscripts submitted for publication must contain a statement to the effect that all human studies have been reviewed by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in an appropriate version of the 1965 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted. Reports of animal experiments must state that the Principles of Laboratory Animal Care (NIH publication no. 86-23 revised 1985) were followed as were applicable national laws (e.g. the current version of the German Law on the Protection of Animals). The Editor-in-Chief reserves the right to reject manuscripts that do not comply with the above-mentioned requirements. Authors will be held responsible for false statements or for failure to fulfill such requirements.