Breast segmentation in infrared thermography from characteristical inframammary shape

IF 2.2 4区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal for Numerical Methods in Biomedical Engineering Pub Date : 2024-07-04 DOI:10.1002/cnm.3843
Francisco J. Alvarez-Padilla, Jorge L. Flores-Nunez, Juan R. Alvarez-Padilla, Francisco J. Gonzalez, Antonio Oceguera-Villanueva, Brian A. Gutierrez-Quiroz
{"title":"Breast segmentation in infrared thermography from characteristical inframammary shape","authors":"Francisco J. Alvarez-Padilla,&nbsp;Jorge L. Flores-Nunez,&nbsp;Juan R. Alvarez-Padilla,&nbsp;Francisco J. Gonzalez,&nbsp;Antonio Oceguera-Villanueva,&nbsp;Brian A. Gutierrez-Quiroz","doi":"10.1002/cnm.3843","DOIUrl":null,"url":null,"abstract":"<p>Infrared thermography is gaining relevance in breast cancer assessment. For this purpose, breast segmentation in thermograms is an important task for performing automatic image analysis and detecting possible temperature changes that indicate the presence of malignancy. However, it is not a simple task since the breast limit borders, especially the top borders, often have low contrast, making it difficult to isolate the breast area. Several algorithms have been proposed for breast segmentation, but these highly depend on the contrast at the lower breast borders and on filtering algorithms to remove false edges. This work focuses on taking advantage of the distinctive inframammary shape to simplify the definition of the lower breast border, regardless of the contrast level, which indeed also provides a strong anatomical reference to support the definition of the poorly marked upper boundary of the breasts, which has been one of the major challenges in the literature. In order to demonstrate viability of the proposed technique for an automatic breast segmentation, we applied it to a database with 180 thermograms and compared their results with those reported by others in the literature. We found that our approach achieved a high performance, in terms of Intersection over Union of 0.934, even higher than that reported by artificial intelligence algorithms. The performance is invariant to breast sizes and thermal contrast of the images.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":"40 8","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cnm.3843","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Infrared thermography is gaining relevance in breast cancer assessment. For this purpose, breast segmentation in thermograms is an important task for performing automatic image analysis and detecting possible temperature changes that indicate the presence of malignancy. However, it is not a simple task since the breast limit borders, especially the top borders, often have low contrast, making it difficult to isolate the breast area. Several algorithms have been proposed for breast segmentation, but these highly depend on the contrast at the lower breast borders and on filtering algorithms to remove false edges. This work focuses on taking advantage of the distinctive inframammary shape to simplify the definition of the lower breast border, regardless of the contrast level, which indeed also provides a strong anatomical reference to support the definition of the poorly marked upper boundary of the breasts, which has been one of the major challenges in the literature. In order to demonstrate viability of the proposed technique for an automatic breast segmentation, we applied it to a database with 180 thermograms and compared their results with those reported by others in the literature. We found that our approach achieved a high performance, in terms of Intersection over Union of 0.934, even higher than that reported by artificial intelligence algorithms. The performance is invariant to breast sizes and thermal contrast of the images.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据乳房下形状特征对红外热成像中的乳房进行分割。
红外热成像技术在乳腺癌评估中的应用越来越广泛。为此,热成像中的乳房分割是一项重要任务,可用于进行自动图像分析和检测表明存在恶性肿瘤的可能温度变化。然而,这并不是一项简单的任务,因为乳房的极限边界,尤其是顶部边界,通常对比度较低,很难将乳房区域分离出来。目前已经提出了几种乳房分割算法,但这些算法在很大程度上依赖于乳房下边界的对比度和滤波算法来去除虚假边缘。这项工作的重点是利用乳房下部的独特形状来简化乳房下部边界的定义,无论对比度如何,这实际上也为乳房上部边界的定义提供了强有力的解剖学参考,而这一直是文献中的主要挑战之一。为了证明所提出的技术在自动乳房分割中的可行性,我们将其应用于一个包含 180 张热敏图的数据库,并将其结果与其他文献中报告的结果进行了比较。我们发现,我们的方法取得了很高的性能,交集大于联合度为 0.934,甚至高于人工智能算法。这种性能不受乳房大小和图像热对比度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
期刊最新文献
Phonoangiographic Diagnosis of Stenosed Arteries: A Computational Fluid Flexible-Structure Acoustic Interaction Study Long-Term Longitudinal Computational Study of a Marfan Syndrome Patient After Hybrid Repair of Aortic Arch Dissection With Parallel Stent-Grafts Total Arch Replacement Versus Hemiarch Replacement in Hemodynamic Performance: A Simulation Study A Computational Study on the Neck-Stem Rectangular Tapered Connection: Effects of Angular Mismatch, Assembly, and Cyclic Loading Comparing Interface Conditions for a 3D–0D Multiscale Interface Coupling With Applications in Tissue Perfusion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1