Ahmed A Ibrahim, Ahmed Elaraby, Omar Almaadawy, Mohamed Abuelazm, Abdul Rhman Hassan, Ali Bakr, Muhammad Ashraf Husain, Hesham Elsayed, Basel Abdelazeem
{"title":"Adjunctive left atrial posterior wall isolation for atrial fibrillation: An updated systematic review and meta-analysis.","authors":"Ahmed A Ibrahim, Ahmed Elaraby, Omar Almaadawy, Mohamed Abuelazm, Abdul Rhman Hassan, Ali Bakr, Muhammad Ashraf Husain, Hesham Elsayed, Basel Abdelazeem","doi":"10.1111/pace.15035","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Posterior left atrial wall isolation (PWI) plus traditional pulmonary vein isolation (PVI) has been proposed as a promising intervention to decrease atrial fibrillation (AF) recurrence. We aim to investigate the efficacy and safety of adding PWI to the traditional PVI in patients with AF.</p><p><strong>Methods: </strong>A systematic review and meta-analysis was conducted using synthesizing randomized controlled trials (RCTs) retrieved by systematically searching PubMed, Web of Science, SCOPUS, EMBASE, and Cochrane through June 14, 2023. We used Stata version 17 to pool dichotomous data using risk ratio (RR) and continuous data using mean difference (MD), with a 95% confidence interval (CI) (PROSPERO ID: CRD42023446227).</p><p><strong>Results: </strong>We included 11 RCTs with a total number of 1534 patients. Combined ablation with PWI + PVI was not associated with any significant difference over PVI only regarding the recurrence of clinical AF (RR: 0.86 with 95% CI [0.70-1.06]), all atrial arrhythmia (RR: 0.93 with 95% CI [0.82-1.07]), nonatrial fibrillation arrhythmia (RR: 1.22 with 95% CI [0.97-1.53]), early AF (RR: 0.89 with 95% CI [0.62-1.27]), and antiarrhythmic drugs at discharge (RR: 0.83 with 95% CI [0.67-1.04]). However, it was associated with increased total ablation duration (minutes) (MD: 12.58 with 95% CI [6.80-18.37]) and total procedure duration (minutes) (MD: 16.77 with 95% CI [9.63-23.91]), without any significant difference regarding adverse events (RR: 1.05 with 95% CI [0.63-1.74]).</p><p><strong>Conclusion: </strong>While the pooled data from PWI + PVI using point-by-point radiofrequency did not suggest a benefit in the recurrence of various atrial arrhythmias compared to PVI alone, PWI+PVI using direct posterior wall ablation, especially with cryoballoon, demonstrated a significant reduction in recurrence of AF/atrial arrhythmias. Also, PWI + PVI significantly increased the ablation and total procedure durations.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15035","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Posterior left atrial wall isolation (PWI) plus traditional pulmonary vein isolation (PVI) has been proposed as a promising intervention to decrease atrial fibrillation (AF) recurrence. We aim to investigate the efficacy and safety of adding PWI to the traditional PVI in patients with AF.
Methods: A systematic review and meta-analysis was conducted using synthesizing randomized controlled trials (RCTs) retrieved by systematically searching PubMed, Web of Science, SCOPUS, EMBASE, and Cochrane through June 14, 2023. We used Stata version 17 to pool dichotomous data using risk ratio (RR) and continuous data using mean difference (MD), with a 95% confidence interval (CI) (PROSPERO ID: CRD42023446227).
Results: We included 11 RCTs with a total number of 1534 patients. Combined ablation with PWI + PVI was not associated with any significant difference over PVI only regarding the recurrence of clinical AF (RR: 0.86 with 95% CI [0.70-1.06]), all atrial arrhythmia (RR: 0.93 with 95% CI [0.82-1.07]), nonatrial fibrillation arrhythmia (RR: 1.22 with 95% CI [0.97-1.53]), early AF (RR: 0.89 with 95% CI [0.62-1.27]), and antiarrhythmic drugs at discharge (RR: 0.83 with 95% CI [0.67-1.04]). However, it was associated with increased total ablation duration (minutes) (MD: 12.58 with 95% CI [6.80-18.37]) and total procedure duration (minutes) (MD: 16.77 with 95% CI [9.63-23.91]), without any significant difference regarding adverse events (RR: 1.05 with 95% CI [0.63-1.74]).
Conclusion: While the pooled data from PWI + PVI using point-by-point radiofrequency did not suggest a benefit in the recurrence of various atrial arrhythmias compared to PVI alone, PWI+PVI using direct posterior wall ablation, especially with cryoballoon, demonstrated a significant reduction in recurrence of AF/atrial arrhythmias. Also, PWI + PVI significantly increased the ablation and total procedure durations.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.