Fundamentals of System Design for Cardiac Pulsed Field Ablation: Optimization of Safety, Efficacy, and Usability.

IF 1.3 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pace-Pacing and Clinical Electrophysiology Pub Date : 2026-01-01 Epub Date: 2025-02-06 DOI:10.1111/pace.15120
Brendan Koop
{"title":"Fundamentals of System Design for Cardiac Pulsed Field Ablation: Optimization of Safety, Efficacy, and Usability.","authors":"Brendan Koop","doi":"10.1111/pace.15120","DOIUrl":null,"url":null,"abstract":"<p><p>The goal of a cardiac pulsed field ablation (PFA) system is to provide safe, effective, and usable therapy for the treatment of cardiac arrhythmias. Achieving this goal is a complex exercise in system design, requiring optimization of catheter, waveform, and dosing. This optimization is often iterative, as myriad design factors are balanced to achieve the goal while making use of computational modeling, bench testing, preclinical animal studies, and human clinical studies to evaluate system performance. It is important for both engineers and clinicians to understand the fundamentals of cardiac PFA system design in order to partner to continuously improve performance of this expanding ablation modality.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":" ","pages":"5-14"},"PeriodicalIF":1.3000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12813650/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15120","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

The goal of a cardiac pulsed field ablation (PFA) system is to provide safe, effective, and usable therapy for the treatment of cardiac arrhythmias. Achieving this goal is a complex exercise in system design, requiring optimization of catheter, waveform, and dosing. This optimization is often iterative, as myriad design factors are balanced to achieve the goal while making use of computational modeling, bench testing, preclinical animal studies, and human clinical studies to evaluate system performance. It is important for both engineers and clinicians to understand the fundamentals of cardiac PFA system design in order to partner to continuously improve performance of this expanding ablation modality.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
心脏脉冲场消融系统设计的基础:安全性、有效性和可用性的优化。
心脏脉冲场消融(PFA)系统的目标是为心律失常的治疗提供安全、有效和可用的治疗方法。实现这一目标是一项复杂的系统设计工作,需要优化导管、波形和剂量。这种优化通常是迭代的,因为在利用计算建模、台架测试、临床前动物研究和人类临床研究来评估系统性能的同时,需要平衡无数的设计因素来实现目标。对于工程师和临床医生来说,了解心脏PFA系统设计的基本原理是很重要的,以便合作不断提高这种扩展消融模式的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pace-Pacing and Clinical Electrophysiology
Pace-Pacing and Clinical Electrophysiology 医学-工程:生物医学
CiteScore
2.70
自引率
5.60%
发文量
209
审稿时长
2-4 weeks
期刊介绍: Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.
期刊最新文献
Coronary Spasm Due to Pulsed Field Ablation: A State-of-the-Art Review. Lesion Formation in Cardiac Pulsed-Field Ablation: Acute to Chronic Cellular Level Changes. Fundamentals of System Design for Cardiac Pulsed Field Ablation: Optimization of Safety, Efficacy, and Usability. Functional Substrate Mapping Using Atrial Decrement Evoked Potentials to Predict Critical Isthmus of Atrial Tachycardia. Gastric Hypomotility After Pulmonary Vein Isolation With or Without Left Atrial Roof Ablation Using a Novel Cryoballoon.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1