A pH ultra-sensitive hydrated iridium oxyhydroxide films electrochemical sensor for label-free detection of Vibrio parahaemolyticus

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-07-03 DOI:10.1016/j.ab.2024.115597
Lin Tian , Yang Li , Huiqing Wang , Xinyi Li , Qian Gao , Yaru Liu , Yao Liu , Qing Wang , Cuiping Ma , Chao Shi
{"title":"A pH ultra-sensitive hydrated iridium oxyhydroxide films electrochemical sensor for label-free detection of Vibrio parahaemolyticus","authors":"Lin Tian ,&nbsp;Yang Li ,&nbsp;Huiqing Wang ,&nbsp;Xinyi Li ,&nbsp;Qian Gao ,&nbsp;Yaru Liu ,&nbsp;Yao Liu ,&nbsp;Qing Wang ,&nbsp;Cuiping Ma ,&nbsp;Chao Shi","doi":"10.1016/j.ab.2024.115597","DOIUrl":null,"url":null,"abstract":"<div><p><em>Vibrio parahaemolyticus</em> (<em>V. parahaemolyticus</em>) is a major foodborne pathogen, which can cause serious foodborne illnesses like diarrhoea. Rapid on-site detection of foodborne pathogens is an ideal way to respond to foodborne illnesses. Herein, we provide an electrochemical sensor for rapid on-site detection. This sensor utilized a pH-sensitive metal-oxide material for the concurrent isothermal amplification and label-free detection of nucleic acids. Based on a pH-sensitive hydrated iridium oxide oxyhydroxide film (HIROF), the electrode transforms the hydrogen ion compound generated during nucleic acid amplification into potential, so as to achieve a real-time detection. The results can be transmitted to a smartphone via Bluetooth. Moreover, HIROF was applied in nucleic acid device detection, with a super-Nernst sensitivity of 77.6 mV/pH in the pH range of 6.0–8.5, and the sensitivity showed the best results so far. Detection of <em>V. parahaemolyticus</em> by this novel method showed a detection limit of 1.0 × 10<sup>3</sup> CFU/mL, while the time consumption was only 30 min, outperforming real-time fluorescence loop-mediated isothermal amplification (LAMP). Therefore, the characteristics of compact, portable, and fast make the sensor more widely used in on-site detection.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003269724001416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Vibrio parahaemolyticus (V. parahaemolyticus) is a major foodborne pathogen, which can cause serious foodborne illnesses like diarrhoea. Rapid on-site detection of foodborne pathogens is an ideal way to respond to foodborne illnesses. Herein, we provide an electrochemical sensor for rapid on-site detection. This sensor utilized a pH-sensitive metal-oxide material for the concurrent isothermal amplification and label-free detection of nucleic acids. Based on a pH-sensitive hydrated iridium oxide oxyhydroxide film (HIROF), the electrode transforms the hydrogen ion compound generated during nucleic acid amplification into potential, so as to achieve a real-time detection. The results can be transmitted to a smartphone via Bluetooth. Moreover, HIROF was applied in nucleic acid device detection, with a super-Nernst sensitivity of 77.6 mV/pH in the pH range of 6.0–8.5, and the sensitivity showed the best results so far. Detection of V. parahaemolyticus by this novel method showed a detection limit of 1.0 × 103 CFU/mL, while the time consumption was only 30 min, outperforming real-time fluorescence loop-mediated isothermal amplification (LAMP). Therefore, the characteristics of compact, portable, and fast make the sensor more widely used in on-site detection.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于无标记检测副溶血性弧菌的 pH 超灵敏水合氢氧化铱薄膜电化学传感器。
副溶血性弧菌(V. parahaemolyticus)是一种主要的食源性病原体,可引起腹泻等严重食源性疾病。现场快速检测食源性病原体是应对食源性疾病的理想方法。在此,我们提供了一种用于现场快速检测的电化学传感器。该传感器采用了一种对 pH 值敏感的金属氧化物材料,可同时对核酸进行等温扩增和无标记检测。该电极以对 pH 值敏感的水合氢氧化铱薄膜(HIROF)为基础,将核酸扩增过程中产生的氢离子化合物转化为电势,从而实现实时检测。检测结果可通过蓝牙传输到智能手机上。此外,HIROF 被应用于核酸装置检测,在 pH 值为 6.0-8.5 的范围内,其超诺恩特灵敏度为 77.6 mV/pH,灵敏度显示出迄今为止最好的结果。用这种新型方法检测副溶血性大肠杆菌的检出限为 1.0×103 CFU/mL,耗时仅为 30 分钟,优于实时荧光环介导等温扩增法(LAMP)。因此,小巧、便携、快速的特点使该传感器在现场检测中得到了更广泛的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
文献相关原料
公司名称产品信息其他信息采购帮参考价格
阿拉丁 All the other chemicals and reagents
¥1743.90~¥14472.00
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1