Comparison of stereotactic radiotherapy and protons for uveal melanoma patients

Emmanuelle Fleury , Jean-Philippe Pignol , Emine Kiliç , Maaike Milder , Caroline van Rij , Nicole Naus , Serdar Yavuzyigitoglu , Wilhelm den Toom , Andras Zolnay , Kees Spruijt , Marco van Vulpen , Petra Trnková , Mischa Hoogeman
{"title":"Comparison of stereotactic radiotherapy and protons for uveal melanoma patients","authors":"Emmanuelle Fleury ,&nbsp;Jean-Philippe Pignol ,&nbsp;Emine Kiliç ,&nbsp;Maaike Milder ,&nbsp;Caroline van Rij ,&nbsp;Nicole Naus ,&nbsp;Serdar Yavuzyigitoglu ,&nbsp;Wilhelm den Toom ,&nbsp;Andras Zolnay ,&nbsp;Kees Spruijt ,&nbsp;Marco van Vulpen ,&nbsp;Petra Trnková ,&nbsp;Mischa Hoogeman","doi":"10.1016/j.phro.2024.100605","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and purpose</h3><p>Uveal melanoma (UM) is the most common primary ocular malignancy. We compared fractionated stereotactic radiotherapy (SRT) with proton therapy, including toxicity risks for UM patients.</p></div><div><h3>Materials and methods</h3><p>For a total of 66 UM patients from a single center, SRT dose distributions were compared to protons using the same planning CT. Fourteen dose-volume parameters were compared in 2-Gy equivalent dose per fraction (EQD2). Four toxicity profiles were evaluated: maculopathy, optic-neuropathy, visual acuity impairment (Profile I); neovascular glaucoma (Profile II); radiation-induced retinopathy (Profile III); and dry-eye syndrome (Profile IV). For Profile III, retina Mercator maps were generated to visualize the geographical location of dose differences.</p></div><div><h3>Results</h3><p>In 9/66 cases, (14 %) proton plans were superior for all dose-volume parameters. Higher T stages benefited more from protons in Profile I, especially tumors located within 3 mm or less from the optic nerve. In Profile II, only 9/66 cases resulted in a better proton plan. In Profile III, better retina volume sparing was always achievable with protons, with a larger gain for T3 tumors. In Profile IV, protons always reduced the risk of toxicity with a median RBE-weighted EQD2 reduction of 15.3 Gy.</p></div><div><h3>Conclusions</h3><p>This study reports the first side-by-side imaging-based planning comparison between protons and SRT for UM patients. Globally, while protons appear almost always better regarding the risk of optic-neuropathy, retinopathy and dry-eye syndrome, for other toxicity like neovascular glaucoma, a plan comparison is warranted. Choice would depend on the prioritization of risks.</p></div>","PeriodicalId":36850,"journal":{"name":"Physics and Imaging in Radiation Oncology","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2405631624000757/pdfft?md5=31bfef88b971c8f260126a467af2f91c&pid=1-s2.0-S2405631624000757-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics and Imaging in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405631624000757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose

Uveal melanoma (UM) is the most common primary ocular malignancy. We compared fractionated stereotactic radiotherapy (SRT) with proton therapy, including toxicity risks for UM patients.

Materials and methods

For a total of 66 UM patients from a single center, SRT dose distributions were compared to protons using the same planning CT. Fourteen dose-volume parameters were compared in 2-Gy equivalent dose per fraction (EQD2). Four toxicity profiles were evaluated: maculopathy, optic-neuropathy, visual acuity impairment (Profile I); neovascular glaucoma (Profile II); radiation-induced retinopathy (Profile III); and dry-eye syndrome (Profile IV). For Profile III, retina Mercator maps were generated to visualize the geographical location of dose differences.

Results

In 9/66 cases, (14 %) proton plans were superior for all dose-volume parameters. Higher T stages benefited more from protons in Profile I, especially tumors located within 3 mm or less from the optic nerve. In Profile II, only 9/66 cases resulted in a better proton plan. In Profile III, better retina volume sparing was always achievable with protons, with a larger gain for T3 tumors. In Profile IV, protons always reduced the risk of toxicity with a median RBE-weighted EQD2 reduction of 15.3 Gy.

Conclusions

This study reports the first side-by-side imaging-based planning comparison between protons and SRT for UM patients. Globally, while protons appear almost always better regarding the risk of optic-neuropathy, retinopathy and dry-eye syndrome, for other toxicity like neovascular glaucoma, a plan comparison is warranted. Choice would depend on the prioritization of risks.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
立体定向放射治疗与质子治疗葡萄膜黑色素瘤患者的比较
背景和目的葡萄膜黑色素瘤(UM)是最常见的原发性眼部恶性肿瘤。我们比较了分次立体定向放射治疗(SRT)和质子治疗,包括 UM 患者的毒性风险。材料和方法对于来自一个中心的总共 66 名 UM 患者,使用相同的计划 CT 比较了 SRT 和质子的剂量分布。以每分 2-Gy 等效剂量 (EQD2) 为单位,比较了 14 个剂量-体积参数。评估了四种毒性情况:黄斑病变、视神经病变、视力损伤(情况 I);新生血管性青光眼(情况 II);辐射诱发视网膜病变(情况 III);干眼症(情况 IV)。结果在 9/66 个病例(14%)中,质子计划在所有剂量-体积参数上都更胜一筹。在轮廓 I 中,较高的 T 期从质子计划中获益更多,尤其是距离视神经 3 毫米以内的肿瘤。在特征 II 中,只有 9/66 的病例采用了更好的质子计划。在Profile III中,质子始终能更好地保留视网膜体积,T3肿瘤的收益更大。在Profile IV中,质子始终能降低毒性风险,中位RBE加权EQD2减少量为15.3 Gy。从全球范围来看,质子在视神经病变、视网膜病变和干眼综合征的风险方面几乎总是更胜一筹,但对于新生血管性青光眼等其他毒性,则需要进行计划比较。选择取决于风险的优先级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology Physics and Astronomy-Radiation
CiteScore
5.30
自引率
18.90%
发文量
93
审稿时长
6 weeks
期刊最新文献
Results of 2023 survey on the use of synthetic computed tomography for magnetic resonance Imaging-only radiotherapy: Current status and future steps Head and neck automatic multi-organ segmentation on Dual-Energy Computed Tomography Automatic segmentation for magnetic resonance imaging guided individual elective lymph node irradiation in head and neck cancer patients Development of a novel 3D-printed dynamic anthropomorphic thorax phantom for evaluation of four-dimensional computed tomography Technical feasibility of delivering a simultaneous integrated boost in partial breast irradiation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1