A Simple Primary Key Algorithm Based Shade Dispersion Method for Maximizing PV Power Generation Under Partial Shading Conditions

Prabhakaran Koothu Kesavan;A. Karthikeyan;Manoj Kumar;Sushant Mandal
{"title":"A Simple Primary Key Algorithm Based Shade Dispersion Method for Maximizing PV Power Generation Under Partial Shading Conditions","authors":"Prabhakaran Koothu Kesavan;A. Karthikeyan;Manoj Kumar;Sushant Mandal","doi":"10.23919/CJEE.2024.000067","DOIUrl":null,"url":null,"abstract":"The output power generation of a photovoltaic (PV) array reduces under partial shading, resulting in multiple local maxima in the PV characteristics and inaccurate tracking of the global maximum power point (GMPP). Various interconnection schemes are available to reduce power losses under partial shading. In this study, a primary key algorithm is proposed for distributing shading across an array. This method is suitable for any \n<tex>$n\\times n$</tex>\n PV array configuration and involves fewer calculations and variables, leading to reduced computational complexity. The power generations of a \n<tex>$9\\times 9$</tex>\n PV array under four different shading conditions were compared with the configurations of: total cross-tied (TCT) and Su Du Ku, physical relocation and fixed column position of modules with fixed electrical connection (PRFCPM-FEC), and magic square (MS) and improved-odd-even-prime (IOEP). The advantage of the proposed method is that once the primary key elements are obtained, the remaining array elements are numbered in a simpler manner. The results obtained using the proposed arrangement show that the power is enhanced with reference to the TCT and is comparable to the Su Do Ku, PRFCPM-FEC, MS, and IOEP reconfigurations.","PeriodicalId":36428,"journal":{"name":"Chinese Journal of Electrical Engineering","volume":"10 2","pages":"93-102"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10586857","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Electrical Engineering","FirstCategoryId":"1087","ListUrlMain":"https://ieeexplore.ieee.org/document/10586857/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

The output power generation of a photovoltaic (PV) array reduces under partial shading, resulting in multiple local maxima in the PV characteristics and inaccurate tracking of the global maximum power point (GMPP). Various interconnection schemes are available to reduce power losses under partial shading. In this study, a primary key algorithm is proposed for distributing shading across an array. This method is suitable for any $n\times n$ PV array configuration and involves fewer calculations and variables, leading to reduced computational complexity. The power generations of a $9\times 9$ PV array under four different shading conditions were compared with the configurations of: total cross-tied (TCT) and Su Du Ku, physical relocation and fixed column position of modules with fixed electrical connection (PRFCPM-FEC), and magic square (MS) and improved-odd-even-prime (IOEP). The advantage of the proposed method is that once the primary key elements are obtained, the remaining array elements are numbered in a simpler manner. The results obtained using the proposed arrangement show that the power is enhanced with reference to the TCT and is comparable to the Su Do Ku, PRFCPM-FEC, MS, and IOEP reconfigurations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种基于主键算法的简单遮阳分散方法,用于在部分遮阳条件下实现光伏发电量最大化
光伏阵列的输出发电量在部分遮挡的情况下会降低,导致光伏特性出现多个局部最大值,以及对全局最大功率点(GMPP)的跟踪不准确。目前有多种互联方案可用于减少部分遮挡下的功率损耗。本研究提出了一种主键算法,用于在整个阵列中分配遮光。这种方法适用于任何 $n\times n$ 的光伏阵列配置,并且涉及的计算和变量较少,从而降低了计算复杂度。在四种不同的遮阳条件下,比较了$9/times 9$ 光伏阵列的发电量:总交叉绑定(TCT)和Su Du Ku、物理搬迁和具有固定电气连接的模块的固定列位置(PRFCPM-FEC)、魔方(MS)和改进型偶偶合(IOEP)配置。建议方法的优势在于,一旦获得主键元素,其余阵列元素的编号方式就会变得更加简单。使用建议的排列方式获得的结果表明,与 TCT 相比,功率有所提高,与 Su Do Ku、PRFCPM-FEC、MS 和 IOEP 重新配置方式相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Chinese Journal of Electrical Engineering
Chinese Journal of Electrical Engineering Energy-Energy Engineering and Power Technology
CiteScore
7.80
自引率
0.00%
发文量
621
审稿时长
12 weeks
期刊最新文献
Contents Front Cover Hybrid Modulation Strategy with Voltage Balancing Control for Four-Level Neutral-Point Clamped Converters Design-Oriented Transient Stability Assessment for Droop-Controlled Converter Considering Grid Voltage Phase-Angle Jump Dynamic Reconstruction of Total-Cross-Tied Photovoltaic Array Based on Arrays Using an Improved Dung Beetle Algorithm
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1