Three-dimensional simultaneous T1 and T2* relaxation times and quantitative susceptibility mapping at 3 T: A multicenter validation study

IF 2.1 4区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Magnetic resonance imaging Pub Date : 2024-07-05 DOI:10.1016/j.mri.2024.07.004
Shohei Fujita , Akifumi Hagiwara , Koichiro Kimura , Yo Taniguchi , Kosuke Ito , Hisako Nagao , Masahiro Takizawa , Wataru Uchida , Koji Kamagata , Ukihide Tateishi , Shigeki Aoki
{"title":"Three-dimensional simultaneous T1 and T2* relaxation times and quantitative susceptibility mapping at 3 T: A multicenter validation study","authors":"Shohei Fujita ,&nbsp;Akifumi Hagiwara ,&nbsp;Koichiro Kimura ,&nbsp;Yo Taniguchi ,&nbsp;Kosuke Ito ,&nbsp;Hisako Nagao ,&nbsp;Masahiro Takizawa ,&nbsp;Wataru Uchida ,&nbsp;Koji Kamagata ,&nbsp;Ukihide Tateishi ,&nbsp;Shigeki Aoki","doi":"10.1016/j.mri.2024.07.004","DOIUrl":null,"url":null,"abstract":"<div><p>We aimed to determine the intra-site repeatability and cross-site reproducibility of T1 and T2* relaxation times and quantitative susceptibility (χ) values obtained through quantitative parameter mapping (QPM) at 3 T. This prospective study included three 3-T scanners with the same hardware and software platform at three sites. The brains of twelve healthy volunteers were scanned three times using QPM at three sites. Intra-site repeatability and cross-site reproducibility were evaluated based on voxel-wise and region-of-interest analyses. The within-subject coefficient of variation (wCV), within-subject standard deviation (wSD), linear regression, Bland–Altman plot, and intraclass correlation coefficient (ICC) were used for evaluation. The intra-site repeatability wCV was 11.9 ± 6.86% for T1 and 3.15 ± 0.03% for T2*, and wSD of χ at 3.35 ± 0.10 parts per billion (ppb). Intra-site ICC(1,<em>k</em>) values for T1, T2*, and χ were 0.878–0.904, 0.972–0.976, and 0.966–0.972, respectively, indicating high consistency within the same scanner. Linear regression analysis revealed a strong agreement between measurements from each site and the site-average measurement, with R-squared values ranging from 0.79 to 0.83 for T1, 0.94–0.95 for T2*, and 0.95–0.96 for χ. The cross-site wCV was 13.4 ± 5.47% for T1 and 3.69 ± 2.25% for T2*, and cross-site wSD of χ at 4.08 ± 3.22 ppb. The cross-site ICC(2,1) was 0.707, 0.913, and 0.902 for T1, T2*, and χ, respectively. QPM provides T1, T2*, and χ values with an intra-site repeatability of &lt;12% and cross-site reproducibility of &lt;14%. These findings may contribute to the development of multisite studies.</p></div>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"112 ","pages":"Pages 100-106"},"PeriodicalIF":2.1000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0730725X24001796","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

We aimed to determine the intra-site repeatability and cross-site reproducibility of T1 and T2* relaxation times and quantitative susceptibility (χ) values obtained through quantitative parameter mapping (QPM) at 3 T. This prospective study included three 3-T scanners with the same hardware and software platform at three sites. The brains of twelve healthy volunteers were scanned three times using QPM at three sites. Intra-site repeatability and cross-site reproducibility were evaluated based on voxel-wise and region-of-interest analyses. The within-subject coefficient of variation (wCV), within-subject standard deviation (wSD), linear regression, Bland–Altman plot, and intraclass correlation coefficient (ICC) were used for evaluation. The intra-site repeatability wCV was 11.9 ± 6.86% for T1 and 3.15 ± 0.03% for T2*, and wSD of χ at 3.35 ± 0.10 parts per billion (ppb). Intra-site ICC(1,k) values for T1, T2*, and χ were 0.878–0.904, 0.972–0.976, and 0.966–0.972, respectively, indicating high consistency within the same scanner. Linear regression analysis revealed a strong agreement between measurements from each site and the site-average measurement, with R-squared values ranging from 0.79 to 0.83 for T1, 0.94–0.95 for T2*, and 0.95–0.96 for χ. The cross-site wCV was 13.4 ± 5.47% for T1 and 3.69 ± 2.25% for T2*, and cross-site wSD of χ at 4.08 ± 3.22 ppb. The cross-site ICC(2,1) was 0.707, 0.913, and 0.902 for T1, T2*, and χ, respectively. QPM provides T1, T2*, and χ values with an intra-site repeatability of <12% and cross-site reproducibility of <14%. These findings may contribute to the development of multisite studies.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3 T 下三维同步 T1 和 T2* 弛豫时间及定量易感性绘图:一项多中心验证研究。
我们的目的是确定在 3 T 下通过定量参数图谱(QPM)获得的 T1 和 T2* 弛豫时间以及定量易感度(χ)值的站内重复性和跨站重复性。这项前瞻性研究包括在三个地点使用具有相同硬件和软件平台的三台 3 T 扫描仪。在三个地点使用 QPM 对 12 名健康志愿者的大脑进行了三次扫描。根据体素分析和感兴趣区分析评估了站内可重复性和跨站可重复性。评估采用了受试者内变异系数(wCV)、受试者内标准偏差(wSD)、线性回归、Bland-Altman 图和类内相关系数(ICC)。T1 的站内重复性 wCV 为 11.9 ± 6.86%,T2* 为 3.15 ± 0.03%,χ 的 wSD 为 3.35 ± 0.10 十亿分之一(ppb)。T1、T2* 和 χ 的站内 ICC(1,k) 值分别为 0.878-0.904、0.972-0.976 和 0.966-0.972,表明同一扫描仪内的一致性很高。线性回归分析表明,每个站点的测量值与站点平均测量值之间的一致性很高,T1 的 R 平方值为 0.79 至 0.83,T2* 为 0.94 至 0.95,χ 为 0.95 至 0.96。T1 和 T2* 的跨位点 wCV 分别为 13.4 ± 5.47% 和 3.69 ± 2.25%,χ 的跨位点 wSD 为 4.08 ± 3.22 ppb。T1、T2* 和 χ 的跨位点 ICC(2,1) 分别为 0.707、0.913 和 0.902。QPM 提供的 T1、T2* 和 χ 值的站内重复性为
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Magnetic resonance imaging
Magnetic resonance imaging 医学-核医学
CiteScore
4.70
自引率
4.00%
发文量
194
审稿时长
83 days
期刊介绍: Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.
期刊最新文献
Preclinical validation of a metasurface-inspired conformal elliptical-cylinder resonator for wrist MRI at 1.5 T. P53 status combined with MRI findings for prognosis prediction of single hepatocellular carcinoma. Predicting progression in triple-negative breast cancer patients undergoing neoadjuvant chemotherapy: Insights from peritumoral radiomics. Deep learning radiomics nomograms predict Isocitrate dehydrogenase (IDH) genotypes in brain glioma: A multicenter study. Reliability of post-contrast deep learning-based highly accelerated cardiac cine MRI for the assessment of ventricular function.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1