{"title":"Correlation Between Implant Stability Quotient and Percussion Sound Frequency","authors":"Wansiri Peeraprasompong,&nbsp;Weerapan Aunmeungtong,&nbsp;Pathawee Khongkhunthian","doi":"10.1002/cre2.917","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To determine the correlation between the primary implant stability quotient and the implant percussion sound frequency.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>A total of 14 pigs' ribs were scanned using a dental cone beam computed tomography (CBCT) scanner to classify the bone specimens into three distinct bone density Hounsfield units (HU) value categories: D1 bone: &gt;1250 HU; D2: 850–1250 HU; D3: &lt;850 HU. Then, 96 implants were inserted: 32 implants in D1 bone, 32 implants in D2 bone, and 32 implants in D3 bone. The primary implant stability quotient (ISQ) was analyzed, and percussion sound was recorded using a wireless microphone connected and analyzed with frequency analysis software.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Statistically significant positive correlations were found between the primary ISQ and the bone density HU value (<i>r</i> = 0.719; <i>p</i> &lt; 0.001), and statistically significant positive correlations between the primary ISQ and the percussion sound frequency (<i>r</i> = 0.606; <i>p</i> &lt; 0.001). Furthermore, significant differences in primary ISQ values and percussion sound frequency were found between D1 and D2 bone, as well as between D1 and D3 bone. However, no significant differences were found in primary ISQ values and percussion sound frequency between D2 and D3 bone.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The primary ISQ value and the percussion sound frequency are positively correlated.</p>\n </section>\n </div>","PeriodicalId":10203,"journal":{"name":"Clinical and Experimental Dental Research","volume":"10 4","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11228351/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cre2.917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To determine the correlation between the primary implant stability quotient and the implant percussion sound frequency.

Materials and Methods

A total of 14 pigs' ribs were scanned using a dental cone beam computed tomography (CBCT) scanner to classify the bone specimens into three distinct bone density Hounsfield units (HU) value categories: D1 bone: >1250 HU; D2: 850–1250 HU; D3: <850 HU. Then, 96 implants were inserted: 32 implants in D1 bone, 32 implants in D2 bone, and 32 implants in D3 bone. The primary implant stability quotient (ISQ) was analyzed, and percussion sound was recorded using a wireless microphone connected and analyzed with frequency analysis software.

Results

Statistically significant positive correlations were found between the primary ISQ and the bone density HU value (r = 0.719; p < 0.001), and statistically significant positive correlations between the primary ISQ and the percussion sound frequency (r = 0.606; p < 0.001). Furthermore, significant differences in primary ISQ values and percussion sound frequency were found between D1 and D2 bone, as well as between D1 and D3 bone. However, no significant differences were found in primary ISQ values and percussion sound frequency between D2 and D3 bone.

Conclusion

The primary ISQ value and the percussion sound frequency are positively correlated.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
种植体稳定性商数与叩击声频率之间的相关性
目的:确定主要种植体稳定性商数与种植体叩击声频率之间的相关性:确定主要种植体稳定性商数与种植体叩击声频率之间的相关性:使用牙科锥形束计算机断层扫描(CBCT)扫描仪对总共 14 根猪肋骨进行扫描,将骨标本分为三个不同的骨密度 Hounsfield 单位(HU)值类别:D1 骨:>1250 HU;D2:850-1250 HU;D3:850-1250 HU:结果主要 ISQ 值与骨密度 HU 值之间存在统计学意义上的明显正相关(r = 0.719;p 结论:主要 ISQ 值与骨密度 HU 值之间存在统计学意义上的明显正相关:原发性 ISQ 值与叩击声频率呈正相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical and Experimental Dental Research
Clinical and Experimental Dental Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.60%
发文量
165
审稿时长
26 weeks
期刊介绍: Clinical and Experimental Dental Research aims to provide open access peer-reviewed publications of high scientific quality representing original clinical, diagnostic or experimental work within all disciplines and fields of oral medicine and dentistry. The scope of Clinical and Experimental Dental Research comprises original research material on the anatomy, physiology and pathology of oro-facial, oro-pharyngeal and maxillofacial tissues, and functions and dysfunctions within the stomatognathic system, and the epidemiology, aetiology, prevention, diagnosis, prognosis and therapy of diseases and conditions that have an effect on the homeostasis of the mouth, jaws, and closely associated structures, as well as the healing and regeneration and the clinical aspects of replacement of hard and soft tissues with biomaterials, and the rehabilitation of stomatognathic functions. Studies that bring new knowledge on how to advance health on the individual or public health levels, including interactions between oral and general health and ill-health are welcome.
期刊最新文献
The Influence of Patient-, Site-, and Implant-Related Factors on Marginal Bone Levels of Dental Implants in a Rural Population in China: A Retrospective Study. Understanding Occlusion and Temporomandibular Joint Function Using Deep Learning and Predictive Modeling Evaluation of Panoramic Radiography Diagnostic Accuracy in the Assessment of Interdental Alveolar Bone Loss Using CBCT Higher Prevalence of Tooth Loss in People With Abdominal Obesity but Normal Weight: Findings From the United States and Scottish Populations A Prediction Model for Lymph Node Metastasis of Oral Squamous Cell Carcinoma Based on Multiple Risk Factors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1