{"title":"Model-based Roentgen Stereophotogrammetric Analysis (RSA) of polyethylene implants","authors":"F.P. Zaribaf , L.A. Koster , B.L. Kaptein , E.C. Pegg , H.S. Gill","doi":"10.1016/j.medengphy.2024.104201","DOIUrl":null,"url":null,"abstract":"<div><p>Model-based Roentgen Stereophotogrammetric Analysis (RSA) is able to measure the migration of metallic prostheses with submillimeter accuracy through contour-detection and 3D surface model matching techniques. However, contour-detection is only possible if the prosthesis is clearly visible in the radiograph; consequently Model-based RSA cannot be directly used for polymeric materials due to their limited X-ray attenuation; this is especially clinically relevant for all-polyethylene implants. In this study the radiopacity of unicompartmental Ultra-High Molecular Weight Polyethylene (UHMWPE) knee bearings was increased by diffusing an oil-based contrast agent into the surface to create three different levels of surface radiopacity. Model-based RSA was performed on the bearings alone, the bearings alongside a metallic component held in position using a phantom, the bearings cemented into a Sawbone tibia, and the bearings at different distances from the femoral component. For each condition the precision and accuracy of zero motion of Model-based RSA were assessed. The radiopaque bearings could be located in the stereo-radiographs using Model-based RSA an accuracy comparable to metallic parts for translational movements (0.03 mm to 0.50 mm). For rotational movements, the accuracy was lower (0.1<sup>∘</sup> to 3.0<sup>∘</sup>). The measurement accuracy was compared for all the radiopacity levels and no significant difference was found (p=0.08). This study demonstrates that contrast enhanced radiopaque polyethylene can be used for Model-based RSA studies and has equivalent translational measurement precision to metallic parts in the superior-inferior direction.</p></div>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1350453324001024/pdfft?md5=cc0745878a1562084c7c41d5ac4a9744&pid=1-s2.0-S1350453324001024-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350453324001024","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Model-based Roentgen Stereophotogrammetric Analysis (RSA) is able to measure the migration of metallic prostheses with submillimeter accuracy through contour-detection and 3D surface model matching techniques. However, contour-detection is only possible if the prosthesis is clearly visible in the radiograph; consequently Model-based RSA cannot be directly used for polymeric materials due to their limited X-ray attenuation; this is especially clinically relevant for all-polyethylene implants. In this study the radiopacity of unicompartmental Ultra-High Molecular Weight Polyethylene (UHMWPE) knee bearings was increased by diffusing an oil-based contrast agent into the surface to create three different levels of surface radiopacity. Model-based RSA was performed on the bearings alone, the bearings alongside a metallic component held in position using a phantom, the bearings cemented into a Sawbone tibia, and the bearings at different distances from the femoral component. For each condition the precision and accuracy of zero motion of Model-based RSA were assessed. The radiopaque bearings could be located in the stereo-radiographs using Model-based RSA an accuracy comparable to metallic parts for translational movements (0.03 mm to 0.50 mm). For rotational movements, the accuracy was lower (0.1∘ to 3.0∘). The measurement accuracy was compared for all the radiopacity levels and no significant difference was found (p=0.08). This study demonstrates that contrast enhanced radiopaque polyethylene can be used for Model-based RSA studies and has equivalent translational measurement precision to metallic parts in the superior-inferior direction.
期刊介绍:
Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.