{"title":"Analysis of the Application Value of Dynamic Navigation Guidance in Oral Implantation.","authors":"Zhuo Wang","doi":"10.3290/j.ijcd.b5594243","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the application of dynamic navigation guidance technology in different implantation scenarios, and to provide a scientific basis for the innovation and advancement of implantation techniques.</p><p><strong>Methods: </strong>Fifteen cases of patients with malocclusions admitted between January 2021 and February 2023 were selected as the study subjects. All patients underwent dynamic navigation-guided oral implantation interventions. CBCT scans were taken after implantation surgery to record deviations of implantation points, including implantation point deviation, endpoint deviation, and angle deviation.</p><p><strong>Results: </strong>Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. CBCT effectively evaluated the state of the patient's periodontal implant, analyzed the state of the patient's lesion area, and improved the quality of implant intervention through CBCT guidance. The implantation point deviation was (0.407±0.193) mm, the endpoint deviation was (0.492±0.201) mm, and the implant angle deviation was (2.162±0.283)°. There was no significant difference in implantation point deviation in the anterior and posterior parts of the upper and lower jaws after intervention (P>0.05). However, there were significant differences in endpoint deviation and implant angle deviation among the anterior and posterior parts of the upper and lower jaws (P<0.05).</p><p><strong>Conclusion: </strong>Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. However, there is relatively greater endpoint deviation and implant angle deviation in the posterior part of the upper jaw.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"0"},"PeriodicalIF":1.8000,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b5594243","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the application of dynamic navigation guidance technology in different implantation scenarios, and to provide a scientific basis for the innovation and advancement of implantation techniques.

Methods: Fifteen cases of patients with malocclusions admitted between January 2021 and February 2023 were selected as the study subjects. All patients underwent dynamic navigation-guided oral implantation interventions. CBCT scans were taken after implantation surgery to record deviations of implantation points, including implantation point deviation, endpoint deviation, and angle deviation.

Results: Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. CBCT effectively evaluated the state of the patient's periodontal implant, analyzed the state of the patient's lesion area, and improved the quality of implant intervention through CBCT guidance. The implantation point deviation was (0.407±0.193) mm, the endpoint deviation was (0.492±0.201) mm, and the implant angle deviation was (2.162±0.283)°. There was no significant difference in implantation point deviation in the anterior and posterior parts of the upper and lower jaws after intervention (P>0.05). However, there were significant differences in endpoint deviation and implant angle deviation among the anterior and posterior parts of the upper and lower jaws (P<0.05).

Conclusion: Dynamic navigation guidance effectively improves the reliability and stability of implantation in oral implant patients. However, there is relatively greater endpoint deviation and implant angle deviation in the posterior part of the upper jaw.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
动态导航引导在口腔种植中的应用价值分析
目的研究动态导航引导技术在不同种植情况下的应用,为种植技术的创新和进步提供科学依据:选取 2021 年 1 月至 2023 年 2 月期间收治的 15 例畸形牙患者作为研究对象。所有患者均接受了动态导航引导下的口腔种植干预。种植手术后进行CBCT扫描,记录种植点偏差,包括种植点偏差、端点偏差和角度偏差:结果:动态导航引导有效提高了口腔种植患者种植的可靠性和稳定性。CBCT有效评估了患者牙周种植体的状态,分析了患者病变区域的状态,通过CBCT引导提高了种植介入的质量。种植点偏差为(0.407±0.193)mm,端点偏差为(0.492±0.201)mm,种植角度偏差为(2.162±0.283)°。干预后,上下颌骨前部和后部的种植点偏差无明显差异(P>0.05)。但是,上下颌骨前部和后部的种植终点偏差和种植角度偏差有明显差异(P结论:动态导航引导能有效提高口腔种植患者种植体植入的可靠性和稳定性。然而,上颌后部的端点偏差和种植体角度偏差相对较大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
期刊最新文献
Impact of Digital Manufacturing Methods on the Accuracy of Ceramic Crowns. Accuracy of imaging software usable in clinical settings for 3D rendering of tooth structures. Digital workflow in oral splint manufacturing. Deep learning for diagnostic charting on pediatric panoramic radiographs. Preformed customized healing abutments in a biologically oriented preparation technique procedure: a 3-year retrospective case-control study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1