Observing and identifying fouled ballast bed: On-site testing with infrared thermography (IRT) and uncovering thermodynamic transfer mechanisms within the ballast bed

IF 4.1 2区 材料科学 Q1 MATERIALS SCIENCE, CHARACTERIZATION & TESTING Ndt & E International Pub Date : 2024-06-24 DOI:10.1016/j.ndteint.2024.103168
Xiaolong Liang , Rongshan Yang , Wenjin Zhu , Caihao Lan , Xinyu Ding , Qiang Zhang , Jiaxiang Chen , Haonan Geng , Haozhe Ding
{"title":"Observing and identifying fouled ballast bed: On-site testing with infrared thermography (IRT) and uncovering thermodynamic transfer mechanisms within the ballast bed","authors":"Xiaolong Liang ,&nbsp;Rongshan Yang ,&nbsp;Wenjin Zhu ,&nbsp;Caihao Lan ,&nbsp;Xinyu Ding ,&nbsp;Qiang Zhang ,&nbsp;Jiaxiang Chen ,&nbsp;Haonan Geng ,&nbsp;Haozhe Ding","doi":"10.1016/j.ndteint.2024.103168","DOIUrl":null,"url":null,"abstract":"<div><p>The ballast bed serves as the foundation of the ballasted track, and its performance is maintained through periodic ballast cleaning. Early detection of fouled ballast bed significantly reduces maintenance workload and capital investment. Some scholars have studied the feasibility of utilizing infrared thermography (IRT) for detecting fouled ballast bed (DBF) and have made some progress. Existing studies have predominantly employed simulated boxes to simulate the ballast bed. To better reflect real-world conditions, this study established two sections of ballast bed on a newly constructed line: one with clean ballast and the other fouled, with a volumetric fouling rate (VFR) of 27.6 % (FI ≈ 21.5 %). Moreover, this paper takes a pivotal step in exploring the thermodynamic transfer mechanisms within the ballast bed, the influences of meteorological factors on the detection effectiveness of IRT, and other detection indicators that could be used for DBF.</p><p>The results demonstrate that the different void fractions and composition substances of the clean and fouled ballast beds (CFB) contribute to their distinct thermodynamic properties. Furthermore, the high specific heat capacity of water exacerbates the thermodynamic property difference between the CFB. In terms of meteorological factors, both the solar radiation intensity (S) and air temperature (T) have a significant positive impact on the temperature of the ballasted structure (STT) and the temperature difference between the CFB (CF-S). Throughout the day, as the S and T increase, the ballast bed surface absorbs more solar heat than it loses, leading to an increase in its surface temperature. When it exceeds the soil temperature (S-S), heat is transferred downward. Since the poor heat conduction of the clean ballast bed, it has a higher surface temperature. As the S and T decrease, heat convection and conduction become dominant, leading to a decrease in the surface temperature of the ballast bed (BT-S). When the BT-S is lower than the S-S, heat is transferred upward, causing the surface temperature of the fouled ballast bed (F-S) to potentially exceed that of the clean ballast bed (C-S). Furthermore, the humidity (H) has a strong negative impact on the STT, while on sunny days following rain, it has a significantly positive impact on the CF-S. The effects of wind speed (W) on the STT and the CF-S are not prominently observed due to its low values during the experiment. Without considering rainfall, higher S and T, combined with reduced W, result in a greater CF-S and are more conducive to advancing fouling detection. Hence, the CF-S can reach up to about 3 °C on a sunny day and may even rise to about 5 °C after rainfall. Nonetheless, the CF-S is only around 0.71 °C on a cloudy day and 0.25 °C at night. Unexpectedly, there is a significant temperature difference between the sleeper and the ballast bed or the steel rail. These indicators could potentially be used for DBF on cloudy days. Overall, these findings demonstrate the feasibility of using IRT for DBF in the field, provding a broader theoretical support for its advancement and implementation.</p></div>","PeriodicalId":18868,"journal":{"name":"Ndt & E International","volume":"147 ","pages":"Article 103168"},"PeriodicalIF":4.1000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ndt & E International","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0963869524001336","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

Abstract

The ballast bed serves as the foundation of the ballasted track, and its performance is maintained through periodic ballast cleaning. Early detection of fouled ballast bed significantly reduces maintenance workload and capital investment. Some scholars have studied the feasibility of utilizing infrared thermography (IRT) for detecting fouled ballast bed (DBF) and have made some progress. Existing studies have predominantly employed simulated boxes to simulate the ballast bed. To better reflect real-world conditions, this study established two sections of ballast bed on a newly constructed line: one with clean ballast and the other fouled, with a volumetric fouling rate (VFR) of 27.6 % (FI ≈ 21.5 %). Moreover, this paper takes a pivotal step in exploring the thermodynamic transfer mechanisms within the ballast bed, the influences of meteorological factors on the detection effectiveness of IRT, and other detection indicators that could be used for DBF.

The results demonstrate that the different void fractions and composition substances of the clean and fouled ballast beds (CFB) contribute to their distinct thermodynamic properties. Furthermore, the high specific heat capacity of water exacerbates the thermodynamic property difference between the CFB. In terms of meteorological factors, both the solar radiation intensity (S) and air temperature (T) have a significant positive impact on the temperature of the ballasted structure (STT) and the temperature difference between the CFB (CF-S). Throughout the day, as the S and T increase, the ballast bed surface absorbs more solar heat than it loses, leading to an increase in its surface temperature. When it exceeds the soil temperature (S-S), heat is transferred downward. Since the poor heat conduction of the clean ballast bed, it has a higher surface temperature. As the S and T decrease, heat convection and conduction become dominant, leading to a decrease in the surface temperature of the ballast bed (BT-S). When the BT-S is lower than the S-S, heat is transferred upward, causing the surface temperature of the fouled ballast bed (F-S) to potentially exceed that of the clean ballast bed (C-S). Furthermore, the humidity (H) has a strong negative impact on the STT, while on sunny days following rain, it has a significantly positive impact on the CF-S. The effects of wind speed (W) on the STT and the CF-S are not prominently observed due to its low values during the experiment. Without considering rainfall, higher S and T, combined with reduced W, result in a greater CF-S and are more conducive to advancing fouling detection. Hence, the CF-S can reach up to about 3 °C on a sunny day and may even rise to about 5 °C after rainfall. Nonetheless, the CF-S is only around 0.71 °C on a cloudy day and 0.25 °C at night. Unexpectedly, there is a significant temperature difference between the sleeper and the ballast bed or the steel rail. These indicators could potentially be used for DBF on cloudy days. Overall, these findings demonstrate the feasibility of using IRT for DBF in the field, provding a broader theoretical support for its advancement and implementation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
观察和识别污垢压载床:使用红外热成像(IRT)进行现场测试,揭示压载层内的热力学传递机制
无砟道床是有砟轨道的基础,通过定期清理无砟道床来保持其性能。及早发现有碴道床可大大减少维护工作量和资金投入。一些学者研究了利用红外热成像(IRT)检测有碴道床(DBF)的可行性,并取得了一些进展。现有研究主要采用模拟箱来模拟压载层。为了更好地反映实际情况,本研究在一条新建线路上建立了两段压载层:一段为清洁压载层,另一段为污垢压载层,污垢体积率 (VFR) 为 27.6 %(FI ≈ 21.5 %)。此外,本文在探索压载层内的热力学传递机制、气象因素对 IRT 检测效果的影响以及其他可用于 DBF 的检测指标方面迈出了关键的一步。结果表明,清洁压载层和污损压载层(CFB)不同的空隙率和组成物质导致了它们不同的热力学特性。此外,水的高比热容也加剧了压载床之间的热力学性质差异。在气象因素方面,太阳辐射强度(S)和空气温度(T)对压载结构的温度(STT)和 CFB 之间的温差(CF-S)都有显著的积极影响。在一天中,随着 S 和 T 的增加,道碴床表面吸收的太阳热量大于其散失的热量,从而导致其表面温度升高。当温度超过土壤温度(S-S)时,热量就会向下传递。由于清洁压载床的热传导性能较差,因此其表面温度较高。随着 S 和 T 的降低,热对流和热传导成为主导,导致道碴床表面温度降低(BT-S)。当 BT-S 低于 S-S 时,热量向上传递,导致污垢压载床(F-S)的表面温度可能超过清洁压载床(C-S)的表面温度。此外,湿度(H)对 STT 有很大的负面影响,而在雨后的晴天,湿度对 CF-S 有显著的正面影响。风速(W)对 STT 和 CF-S 的影响并不明显,因为实验期间风速值较低。在不考虑降雨量的情况下,较高的 S 和 T 加上较低的 W 会产生较大的 CF-S,更有利于推进污垢检测。因此,CF-S 在晴天可高达约 3 °C,降雨后甚至可升至约 5 °C。然而,阴天的 CF-S 只有约 0.71 °C,夜间为 0.25 °C。意想不到的是,枕木与道碴床或钢轨之间的温差很大。这些指标有可能用于阴天的 DBF。总之,这些研究结果证明了将 IRT 用于现场 DBF 的可行性,为其推进和实施提供了更广泛的理论支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ndt & E International
Ndt & E International 工程技术-材料科学:表征与测试
CiteScore
7.20
自引率
9.50%
发文量
121
审稿时长
55 days
期刊介绍: NDT&E international publishes peer-reviewed results of original research and development in all categories of the fields of nondestructive testing and evaluation including ultrasonics, electromagnetics, radiography, optical and thermal methods. In addition to traditional NDE topics, the emerging technology area of inspection of civil structures and materials is also emphasized. The journal publishes original papers on research and development of new inspection techniques and methods, as well as on novel and innovative applications of established methods. Papers on NDE sensors and their applications both for inspection and process control, as well as papers describing novel NDE systems for structural health monitoring and their performance in industrial settings are also considered. Other regular features include international news, new equipment and a calendar of forthcoming worldwide meetings. This journal is listed in Current Contents.
期刊最新文献
Characterization of heat-treated bearing rings via measurement of electromagnetic properties for pulsed eddy current evaluation Optimising full waveform inversion with inhomogeneous transducers: Parameters and considerations for successful implementation A simplified procedure for evaluation of damage-depth in concrete exposed to high temperature using the impact-echo method Novel fast full-wavefield modeling of air-coupled surface waves and its implications for non-contact pavement testing A novel damage localization method of Circular Phased Array using Minimum Variance Distortionless Response Beamforming with Autocorrelation Matrix Diagonal Loading
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1