Fabrication of TiO2 Nanoparticle Coating on Stainless Steel 316L and Its Assessment for Orthopaedic Applications

Manjit Singh Jadon, Sandeep Kumar
{"title":"Fabrication of TiO2 Nanoparticle Coating on Stainless Steel 316L and Its Assessment for Orthopaedic Applications","authors":"Manjit Singh Jadon, Sandeep Kumar","doi":"10.3991/ijoe.v20i10.49177","DOIUrl":null,"url":null,"abstract":"The study aims to investigate the efficacy of titanium dioxide (TiO2) nanoparticle coating on stainless steel 316L (SS 316L) orthopaedic implants to enhance their biocompatibility, osseointegration, and durability. The TiO2 nanoparticles were synthesized via the hydrothermal method and extensively characterized for composition, crystallinity, and morphology using techniques such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM) with energy dispersive X-ray analysis (EDX), corroborated by elemental mapping. SEM and XRD analyses revealed the synthesized nanoparticles have a spherical shape and an average size of approximately 23 nanometres. The synthesized TiO2 nanoparticles were uniformly coated on SS 316L substrates using the spin coating technique, as confirmed by SEM images. Cell viability of the synthesized TiO2 nanoparticles, as well as uncoated and TiO2 nanoparticle-coated SS 316L substrates, was evaluated using the MTT (3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide) assay against the NIH-3T3 mouse embryonic fibroblast cell line. The results demonstrated that the TiO2 nanoparticle-coated SS 316L substrate showed a significant increase of 22.87% in cell viability as compared to the uncoated SS 316L substrate. A ball-on-disc tribometer was employed to assess wear and friction resistance at various speeds, viz., 150 rpm, 300 rpm, and 450 rpm, under 30N load conditions for five minutes. The results collectively indicate a substantial improvement in the performance of TiO2 nanoparticle-coated SS 316L substrates for orthopaedic applications.","PeriodicalId":507997,"journal":{"name":"International Journal of Online and Biomedical Engineering (iJOE)","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Online and Biomedical Engineering (iJOE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3991/ijoe.v20i10.49177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The study aims to investigate the efficacy of titanium dioxide (TiO2) nanoparticle coating on stainless steel 316L (SS 316L) orthopaedic implants to enhance their biocompatibility, osseointegration, and durability. The TiO2 nanoparticles were synthesized via the hydrothermal method and extensively characterized for composition, crystallinity, and morphology using techniques such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM) with energy dispersive X-ray analysis (EDX), corroborated by elemental mapping. SEM and XRD analyses revealed the synthesized nanoparticles have a spherical shape and an average size of approximately 23 nanometres. The synthesized TiO2 nanoparticles were uniformly coated on SS 316L substrates using the spin coating technique, as confirmed by SEM images. Cell viability of the synthesized TiO2 nanoparticles, as well as uncoated and TiO2 nanoparticle-coated SS 316L substrates, was evaluated using the MTT (3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide) assay against the NIH-3T3 mouse embryonic fibroblast cell line. The results demonstrated that the TiO2 nanoparticle-coated SS 316L substrate showed a significant increase of 22.87% in cell viability as compared to the uncoated SS 316L substrate. A ball-on-disc tribometer was employed to assess wear and friction resistance at various speeds, viz., 150 rpm, 300 rpm, and 450 rpm, under 30N load conditions for five minutes. The results collectively indicate a substantial improvement in the performance of TiO2 nanoparticle-coated SS 316L substrates for orthopaedic applications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不锈钢 316L 上二氧化钛纳米粒子涂层的制备及其骨科应用评估
本研究旨在探讨二氧化钛(TiO2)纳米粒子涂层在不锈钢 316L (SS 316L)骨科植入物上的功效,以增强其生物相容性、骨结合性和耐用性。通过水热法合成了二氧化钛纳米粒子,并利用 X 射线衍射 (XRD)、傅立叶变换红外光谱 (FTIR)、扫描电子显微镜 (SEM) 和能量色散 X 射线分析 (EDX) 等技术对其成分、结晶度和形态进行了广泛表征,并通过元素图谱进行了证实。扫描电子显微镜和 XRD 分析表明,合成的纳米粒子呈球形,平均尺寸约为 23 纳米。利用旋涂技术将合成的 TiO2 纳米粒子均匀地涂在 SS 316L 基质上,这一点已通过扫描电镜图像得到证实。使用 MTT(3-(4, 5-二甲基噻唑-2-基)-2, 5-二苯基溴化四氮唑)测定法对 NIH-3T3 小鼠胚胎成纤维细胞系评估了合成的 TiO2 纳米粒子以及未涂层和涂层 TiO2 纳米粒子的 SS 316L 基底的细胞活力。结果表明,与未涂覆的 SS 316L 基质相比,涂覆了 TiO2 纳米粒子的 SS 316L 基质的细胞存活率显著提高了 22.87%。在 30N 负载条件下,使用盘上球摩擦仪在不同转速(即 150 rpm、300 rpm 和 450 rpm)下评估磨损和摩擦阻力,持续时间为五分钟。总的结果表明,TiO2 纳米粒子涂层的 SS 316L 基材在矫形外科应用中的性能得到了大幅提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
XAI-PhD: Fortifying Trust of Phishing URL Detection Empowered by Shapley Additive Explanations Improving the Accuracy of Oncology Diagnosis: A Machine Learning-Based Approach to Cancer Prediction Social Robots, Mindfulness, and Kindergarten Blockchain of Things for Securing and Managing Water 4.0 Applications Intelligent Interconnected Healthcare System: Integrating IoT and Big Data for Personalized Patient Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1