Use of two different methods for glucose determination in sheep under normoglycemic, hypoglycemic, and hyperglycemic conditions: an evaluation of practical diagnostic methods in ovines

IF 17.7 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-07-16 DOI:10.1071/an24165
M. G. Chenard, Jade de Menezes Paes Bastos, Matheus Dias Valle, Isabelle Magalhães da Cunha, N. Alencar, Daniel Augusto Barroso Lessa, Guilherme Nunes de Souza, Nathalie Costa da Cunha, M. A. Helayel
{"title":"Use of two different methods for glucose determination in sheep under normoglycemic, hypoglycemic, and hyperglycemic conditions: an evaluation of practical diagnostic methods in ovines","authors":"M. G. Chenard, Jade de Menezes Paes Bastos, Matheus Dias Valle, Isabelle Magalhães da Cunha, N. Alencar, Daniel Augusto Barroso Lessa, Guilherme Nunes de Souza, Nathalie Costa da Cunha, M. A. Helayel","doi":"10.1071/an24165","DOIUrl":null,"url":null,"abstract":"Context Animals can present abnormal blood glucose concentrations because of various diseases or pathological conditions, stress, or hunger. Early diagnosis prevents complications, economic losses, and death. The use of a portable glucometer (PGM) has been shown to be a good, simple, and practical alternative method with good precision and accuracy for assessing blood glucose in humans and companion animals. Aims The objective of this work was to evaluate the accuracy and reliability of a portable glucometer (PGM) for assessing glycemia in normoglycemic, hypoglycemic, and hyperglycemic sheep. Methods Blood glucose was evaluated in 60 normoglycemic, 15 hypoglycemic, and 15 hyperglycemic sheep. Blood samples were collected and analysed within 2 h by using PGM and the enzymatic method (EM). Each test was evaluated for sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve for two cutoff points, namely, one for hypoglycemia and the other for hyperglycemia. Key results The results of the Kolmogorov–Smirnov test (P < 0.05) for all groups evaluated did not show a normal distribution for the values evaluated by PGM and EM. Despite the significant difference found between the medians of the methods and the low homogeneity according to the coefficient of variation (CV), there was a homogeneous and linear dispersion of the results. The Bland–Altman test showed that the mean difference between the two methods was close to zero, denoting good agreement, precision, and accuracy of PGM when compared to EM. Conclusions PGM presents high accuracy and precision for assessing glycemia in sheep, providing satisfactory and reliable results when compared with EM. Implications The use of PGM facilitates the veterinarian’s routine, promoting early diagnosis, field examinations, and monitoring of metabolic diseases.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"7 19","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1071/an24165","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Context Animals can present abnormal blood glucose concentrations because of various diseases or pathological conditions, stress, or hunger. Early diagnosis prevents complications, economic losses, and death. The use of a portable glucometer (PGM) has been shown to be a good, simple, and practical alternative method with good precision and accuracy for assessing blood glucose in humans and companion animals. Aims The objective of this work was to evaluate the accuracy and reliability of a portable glucometer (PGM) for assessing glycemia in normoglycemic, hypoglycemic, and hyperglycemic sheep. Methods Blood glucose was evaluated in 60 normoglycemic, 15 hypoglycemic, and 15 hyperglycemic sheep. Blood samples were collected and analysed within 2 h by using PGM and the enzymatic method (EM). Each test was evaluated for sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve for two cutoff points, namely, one for hypoglycemia and the other for hyperglycemia. Key results The results of the Kolmogorov–Smirnov test (P < 0.05) for all groups evaluated did not show a normal distribution for the values evaluated by PGM and EM. Despite the significant difference found between the medians of the methods and the low homogeneity according to the coefficient of variation (CV), there was a homogeneous and linear dispersion of the results. The Bland–Altman test showed that the mean difference between the two methods was close to zero, denoting good agreement, precision, and accuracy of PGM when compared to EM. Conclusions PGM presents high accuracy and precision for assessing glycemia in sheep, providing satisfactory and reliable results when compared with EM. Implications The use of PGM facilitates the veterinarian’s routine, promoting early diagnosis, field examinations, and monitoring of metabolic diseases.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在正常血糖、低血糖和高血糖条件下使用两种不同方法测定绵羊的葡萄糖:对绵羊实用诊断方法的评估
背景 动物会因各种疾病或病理状况、压力或饥饿而导致血糖浓度异常。早期诊断可预防并发症、经济损失和死亡。使用便携式血糖仪(PGM)已被证明是一种良好、简单、实用的替代方法,具有良好的精确性和准确性,可用于评估人类和伴侣动物的血糖。目的 评估便携式血糖仪(PGM)评估血糖正常、血糖过低和血糖过高绵羊血糖的准确性和可靠性。方法 对 60 只正常血糖绵羊、15 只低血糖绵羊和 15 只高血糖绵羊的血糖进行评估。采集血样并在 2 小时内用 PGM 和酶法(EM)进行分析。对每种检测方法的灵敏度、特异性以及两个截断点(一个为低血糖,另一个为高血糖)的接收器操作特征曲线下面积进行了评估。主要结果 对所有评估组进行的 Kolmogorov-Smirnov 检验(P < 0.05)结果显示,PGM 和 EM 评估值不呈正态分布。尽管这两种方法的中位数之间存在明显差异,而且根据变异系数(CV)计算的同质性较低,但结果仍呈均匀的线性分布。Bland-Altman 检验表明,两种方法的平均差异接近零,这表明与 EM 相比,PGM 具有良好的一致性、精确性和准确性。结论 PGM 在评估绵羊血糖方面具有较高的准确性和精确度,与 EM 相比可提供令人满意的可靠结果。意义 使用 PGM 方便了兽医的日常工作,促进了代谢疾病的早期诊断、现场检查和监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Corrigendum to "Do All Isolated Traumatic Subarachnoid Hemorrhages Need to Be Transferred to a Level 1 Trauma Center?" Unique Defect Characteristics of Antimony Chalcogenide Photovoltaic Materials. Bright, Biocompatible NIR-II-Emitting I-VI Quantum Dots for Rapid Disease Diagnosis. Mechanistic Insights into Dinitrogen Reduction to Ammonia in Light-Controlled Nanocrystal:Nitrogenase Complexes. Supramolecular Control of Fullerene Recognition and Reactivity through Nanocapsule Confinement.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1