Evaluation of flat ridge rehabilitation using an intraoral custom-made distraction device at four weeks versus eight weeks and its impact on dental implant efficacy: A comparative study

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Saudi Dental Journal Pub Date : 2024-07-06 DOI:10.1016/j.sdentj.2024.07.007
Sherif S. Hassan , Mohamed A. Shuman , Alaa Z. Makke , Alaa W. AlQutub , Ibraheem K. Bamaga , Reda A. Nofal , Mohammed H. Al-Kabany
{"title":"Evaluation of flat ridge rehabilitation using an intraoral custom-made distraction device at four weeks versus eight weeks and its impact on dental implant efficacy: A comparative study","authors":"Sherif S. Hassan ,&nbsp;Mohamed A. Shuman ,&nbsp;Alaa Z. Makke ,&nbsp;Alaa W. AlQutub ,&nbsp;Ibraheem K. Bamaga ,&nbsp;Reda A. Nofal ,&nbsp;Mohammed H. Al-Kabany","doi":"10.1016/j.sdentj.2024.07.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>This study aimed to evaluate alveolar bone height enhancement using a custom-made distractor to evaluate its ability to support dental implants.</p></div><div><h3>Method</h3><p>The left mandibular premolars of nine dogs were extracted, followed by alveoloplasty to simulate an atrophic ridge. The dogs were divided into three groups: groups I and II received distractors followed by dental implants, while group III received implants alone. Distractors remained in place for 4 weeks in group I and 8 weeks in group II for consolidation. Subsequently, the distractors were removed, and a titanium dental implant was immediately inserted during the same visit. In the third group, implants were placed in the same area as noted. The implant was left in position for 8 weeks, after which the left hemimandible underwent dual-energy X-ray absorptiometry and histological analysis, focusing on the region of interest (ROI)<span><span><sup>1</sup></span></span> mesial and distal to the dental implant.</p></div><div><h3>Results</h3><p>Densitometric analysis revealed notable osseointegration between the regenerated bone adjacent to the dental implant. Notably, there were significant differences in osseointegration between groups I and II. Moreover, osseointegration levels were similar between groups II and III, where no distraction device was employed. Histological findings showed the formation of new bone in the distraction gap, with more advanced maturation noted in the 8-week group. It is worth noting that the integration between bone and implants in the third group surpasses that of the distraction groups.</p></div><div><h3>Conclusion</h3><p>Using the distraction device for only 4 weeks is acceptable to meet the criteria for implant placement. The small size of the distraction device reduces tissue reaction after surgery because it eliminates the necessity of complex surgeries that may require bone grafting. Density measurements and histological observations indicate that the distractor promotes the generation of enough bone for prosthetic rehabilitation with dental implants.</p></div>","PeriodicalId":47246,"journal":{"name":"Saudi Dental Journal","volume":"36 9","pages":"Pages 1241-1247"},"PeriodicalIF":1.7000,"publicationDate":"2024-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1013905224002049/pdfft?md5=2fc7bffe8163b19e0f2ef8b240851110&pid=1-s2.0-S1013905224002049-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1013905224002049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background

This study aimed to evaluate alveolar bone height enhancement using a custom-made distractor to evaluate its ability to support dental implants.

Method

The left mandibular premolars of nine dogs were extracted, followed by alveoloplasty to simulate an atrophic ridge. The dogs were divided into three groups: groups I and II received distractors followed by dental implants, while group III received implants alone. Distractors remained in place for 4 weeks in group I and 8 weeks in group II for consolidation. Subsequently, the distractors were removed, and a titanium dental implant was immediately inserted during the same visit. In the third group, implants were placed in the same area as noted. The implant was left in position for 8 weeks, after which the left hemimandible underwent dual-energy X-ray absorptiometry and histological analysis, focusing on the region of interest (ROI)1 mesial and distal to the dental implant.

Results

Densitometric analysis revealed notable osseointegration between the regenerated bone adjacent to the dental implant. Notably, there were significant differences in osseointegration between groups I and II. Moreover, osseointegration levels were similar between groups II and III, where no distraction device was employed. Histological findings showed the formation of new bone in the distraction gap, with more advanced maturation noted in the 8-week group. It is worth noting that the integration between bone and implants in the third group surpasses that of the distraction groups.

Conclusion

Using the distraction device for only 4 weeks is acceptable to meet the criteria for implant placement. The small size of the distraction device reduces tissue reaction after surgery because it eliminates the necessity of complex surgeries that may require bone grafting. Density measurements and histological observations indicate that the distractor promotes the generation of enough bone for prosthetic rehabilitation with dental implants.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估使用口内定制牵引装置在四周与八周内进行平脊修复的效果及其对种植牙疗效的影响:比较研究
背景本研究旨在评估使用定制的牵引器增强牙槽骨高度的情况,以评估其支持牙科植入物的能力。方法拔除九只狗的左下颌前磨牙,然后进行牙槽骨成形术,以模拟萎缩的牙脊。这些狗被分为三组:I 组和 II 组先使用牵引器,然后植入种植体;III 组仅植入种植体。第一组和第二组的牵引器分别放置 4 周和 8 周以进行巩固。随后,移除牵引器,并在同一次就诊中立即植入钛种植体。在第三组中,种植体被植入上述相同区域。种植体放置 8 周后,对左下颌骨进行双能 X 射线吸收测定和组织学分析,重点是种植体中、远端感兴趣区(ROI)1。值得注意的是,第一组和第二组之间的骨整合存在明显差异。此外,未使用牵引装置的 II 组和 III 组之间的骨结合水平相似。组织学结果显示,牵引间隙中有新骨形成,8 周组的新骨成熟度更高。值得注意的是,第三组骨与种植体的融合度超过了牵引组。牵引装置体积小,可减少术后组织反应,因为它避免了可能需要植骨的复杂手术。密度测定和组织学观察结果表明,牵引器能促进足够骨量的生成,以便通过种植体进行修复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Saudi Dental Journal
Saudi Dental Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.60
自引率
0.00%
发文量
86
审稿时长
22 weeks
期刊介绍: Saudi Dental Journal is an English language, peer-reviewed scholarly publication in the area of dentistry. Saudi Dental Journal publishes original research and reviews on, but not limited to: • dental disease • clinical trials • dental equipment • new and experimental techniques • epidemiology and oral health • restorative dentistry • periodontology • endodontology • prosthodontics • paediatric dentistry • orthodontics and dental education Saudi Dental Journal is the official publication of the Saudi Dental Society and is published by King Saud University in collaboration with Elsevier and is edited by an international group of eminent researchers.
期刊最新文献
Editorial Board Assessing the quality of AI information from ChatGPT regarding oral surgery, preventive dentistry, and oral cancer: An exploration study An in vitro study of fluoride-preloaded halloysite nanotubes to enhance the fluoride release in conventional and resin-modified glass ionomer cements Association between dental diseases and stroke Drug delivery systems in periodontitis: A visualization and bibliometric analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1