The use of cardiac magnetic resonance imaging for the evaluation of pulmonary hypertension

Shaimaa Saeed Mohamed, Mona Mansour Ahmed, T. M. Ali, R. Elkorashy, A M Osman, Maryam Aly Abd Elkader, Sameh Nabil Kamel
{"title":"The use of cardiac magnetic resonance imaging for the evaluation of pulmonary hypertension","authors":"Shaimaa Saeed Mohamed, Mona Mansour Ahmed, T. M. Ali, R. Elkorashy, A M Osman, Maryam Aly Abd Elkader, Sameh Nabil Kamel","doi":"10.4103/ecdt.ecdt_134_22","DOIUrl":null,"url":null,"abstract":"\n \n Evaluate the utility of cardiac magnetic resonance imaging to estimate the principle hemodynamic parameters that are measured by right heart catheterization in a noninvasive manner i.e. mean pulmonary artery pressure, pulmonary vascular resistance and pulmonary artery wedge pressure through cardiac magnetic resonance based numerical models.\n \n \n \n 29 pulmonary hypertension patients, fitting the inclusion criteria were randomly selected and included in the study. CMR Imaging and right side heart catheter (RHC) were performed within one month. 3 Cardiac MRI based models in literature that showed high accuracy were tested. Two equations for mPAP calculation; mPAP=-231.423 + 53.8(loge inter-ventricular septal angle)+log10(right ventricular mass divided by left ventricular mass) i.e ventricular mass index X 8.708+area of pulmonary artery in diastole X 0.009 and mPAP = –4.6+(0.32*septal angle)+(ventricular mass index × 16.3). One equation for PAWP; PAWP = left atrial volume index +6.43 × 0.22.\n \n \n \n The Altman and Bland correlation between mPAP invasively measured and CMR-estimated mPAP had good correlation with r= 0.594 and r=0.599 (P<0.001) for CMR based mPAP model 1 and 2, respectively. The calculated mean bias between the RHC-derived and CMR-estimated mPAP was 7.9 (agreement interval -24.8 to 40.6 mm Hg) and mean bias -3 (agreement interval -34.8 to 28.2 mm Hg) for CMR based mPAP model 1 and 2, respectively. There was no correlation between invasively measured and CMR-estimated PAWP with (P =0.092) for CMR based PAWP model. The mean bias between the RHC-derived and CMR-estimated PAWP was 2.4 (agreement interval –13.5 to 18.2 mm Hg). The correlation between invasively calculated and CMR-estimated PVR had good correlation with r=0.703 and r=0.704 (P<0.001) for CMR based PVR model 1 and 2, respectively. The mean bias between the RHC-measured and CMR-estimated mPAP was 0.6 (agreement interval -11.6 to 12.8 mm Hg) and mean bias -1.3 (agreement interval -12.1 to 9.5 mm Hg) for CMR based mPAP model 1 and 2, respectively.\n \n \n \n Our results showed good correlations between CMR findings and RHC as regard mPAP and PVR. Thus, estimation of mPAP, PAWP and PVR non-invasively using CMR is feasible but needs further studies to improve accuracy.\n","PeriodicalId":519530,"journal":{"name":"The Egyptian Journal of Chest Diseases and Tuberculosis","volume":"4 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Egyptian Journal of Chest Diseases and Tuberculosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ecdt.ecdt_134_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Evaluate the utility of cardiac magnetic resonance imaging to estimate the principle hemodynamic parameters that are measured by right heart catheterization in a noninvasive manner i.e. mean pulmonary artery pressure, pulmonary vascular resistance and pulmonary artery wedge pressure through cardiac magnetic resonance based numerical models. 29 pulmonary hypertension patients, fitting the inclusion criteria were randomly selected and included in the study. CMR Imaging and right side heart catheter (RHC) were performed within one month. 3 Cardiac MRI based models in literature that showed high accuracy were tested. Two equations for mPAP calculation; mPAP=-231.423 + 53.8(loge inter-ventricular septal angle)+log10(right ventricular mass divided by left ventricular mass) i.e ventricular mass index X 8.708+area of pulmonary artery in diastole X 0.009 and mPAP = –4.6+(0.32*septal angle)+(ventricular mass index × 16.3). One equation for PAWP; PAWP = left atrial volume index +6.43 × 0.22. The Altman and Bland correlation between mPAP invasively measured and CMR-estimated mPAP had good correlation with r= 0.594 and r=0.599 (P<0.001) for CMR based mPAP model 1 and 2, respectively. The calculated mean bias between the RHC-derived and CMR-estimated mPAP was 7.9 (agreement interval -24.8 to 40.6 mm Hg) and mean bias -3 (agreement interval -34.8 to 28.2 mm Hg) for CMR based mPAP model 1 and 2, respectively. There was no correlation between invasively measured and CMR-estimated PAWP with (P =0.092) for CMR based PAWP model. The mean bias between the RHC-derived and CMR-estimated PAWP was 2.4 (agreement interval –13.5 to 18.2 mm Hg). The correlation between invasively calculated and CMR-estimated PVR had good correlation with r=0.703 and r=0.704 (P<0.001) for CMR based PVR model 1 and 2, respectively. The mean bias between the RHC-measured and CMR-estimated mPAP was 0.6 (agreement interval -11.6 to 12.8 mm Hg) and mean bias -1.3 (agreement interval -12.1 to 9.5 mm Hg) for CMR based mPAP model 1 and 2, respectively. Our results showed good correlations between CMR findings and RHC as regard mPAP and PVR. Thus, estimation of mPAP, PAWP and PVR non-invasively using CMR is feasible but needs further studies to improve accuracy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用心脏磁共振成像评估肺动脉高压
通过基于心脏磁共振的数字模型,评估心脏磁共振成像在无创估算右心导管测量的主要血液动力学参数(即平均肺动脉压、肺血管阻力和肺动脉楔压)方面的实用性。 研究随机选取了 29 名符合纳入标准的肺动脉高压患者。在一个月内进行了心脏磁共振成像和右侧心脏导管(RHC)检查。测试了 3 个基于心脏核磁共振成像的模型,这些模型在文献中显示出较高的准确性。mPAP 的两个计算公式为:mPAP=-231.423 + 53.8(loge 室间隔角度)+log10(右心室质量除以左心室质量),即心室质量指数 X 8.708+ 舒张期肺动脉面积 X 0.009;mPAP = -4.6+(0.32* 室间隔角度)+(心室质量指数 × 16.3)。PAWP 的计算公式为:PAWP = 左心房容积指数 +6.43 × 0.22。 有创测量的 mPAP 与 CMR 估算的 mPAP 之间的 Altman 和 Bland 相关性良好,基于 CMR 的 mPAP 模型 1 和 2 分别为 r= 0.594 和 r=0.599 (P<0.001)。对于基于 CMR 的 mPAP 模型 1 和 2,RHC 导出的 mPAP 与 CMR 估算的 mPAP 之间的计算平均偏差分别为 7.9(一致区间 -24.8 至 40.6 mm Hg)和平均偏差 -3(一致区间 -34.8 至 28.2 mm Hg)。对于基于 CMR 的 PAWP 模型,有创测量和 CMR 估算的 PAWP 之间没有相关性(P =0.092)。RHC 导出的 PAWP 与 CMR 估算的 PAWP 之间的平均偏差为 2.4(一致区间为 -13.5 至 18.2 mm Hg)。有创计算的 PVR 与 CMR 估算的 PVR 之间具有良好的相关性,基于 CMR 的 PVR 模型 1 和 2 分别为 r=0.703 和 r=0.704 (P<0.001)。对于基于 CMR 的 mPAP 模型 1 和 2,RHC 测量的 mPAP 与 CMR 估算的 mPAP 之间的平均偏差分别为 0.6(一致区间 -11.6 至 12.8 mm Hg)和平均偏差-1.3(一致区间 -12.1 至 9.5 mm Hg)。 我们的结果表明,CMR 结果与 RHC 之间在 mPAP 和 PVR 方面存在良好的相关性。因此,使用 CMR 无创估计 mPAP、PAWP 和 PVR 是可行的,但需要进一步研究以提高准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of clinical management and radiological affection of coronavirus disease 2019 patients under isolation: an experience from a University Hospital Randomized prospective trial comparing two schedules of hypofractionated adjuvant radiotherapy 3 weeks against 1 week fractionation regimen in females with breast cancer ECG abnormalities in chronic obstructive pulmonary disease exacerbation: can the ECG record still astound us? A prospective study Strengthening the transportation network to improve diagnosis of multidrug-resistant tuberculosis: role of postal services Comparative evaluation of baseline SOFA score and CURB-65 score in predicting patient severity and outcome in COVID-19 patients admitted to a tertiary care ICU
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1