{"title":"Reliable unit strength correlations to predict the compressive strength of grouted concrete masonry","authors":"Julian Thamboo, Mathavanayakam Sathurshan, Tatheer Zahra","doi":"10.1617/s11527-024-02417-8","DOIUrl":null,"url":null,"abstract":"<div><p>Compressive strength of grouted concrete masonry is an important parameter to design reinforced/grouted concrete masonry walls. The design standards stipulate two methods to determine the compressive strength of masonry (1) using tabulated unit strength and mortar type, and (2) testing representative masonry prisms. The compressive strength prediction of grouted concrete masonry is influenced by compressive strength values of hollow blocks, mortar and grout, and their geometries. Therefore, a multi-level approach was employed in this study to improve the existing unit strength correlations of the standards for more reliable prediction of compressive strengths of grouted concrete masonry. The existing methods to determine the compressive strength of grouted masonry were critically appraised and a database of compression tests of grouted concrete masonry prisms/wallettes was developed. This database was then used to evaluate the correlations between the compressive strengths of block, mortar, grout and masonry. The applicability of existing unit strength correlations from the design standards and literature were assessed and their relevancy and limitations are highlighted. Subsequently, updated sets of unit strength correlations are proposed in this study, through statistical reliability analyses of the predictions against the experimental results included in the database. The proposed unit strength correlations were classified according to the mortar type/strengths (≤ 10 MPa and > 10 MPa). It has been shown that the new correlations are more structurally reliable than the existing unit strength correlations through comparing the 95th percentile error values.</p></div>","PeriodicalId":691,"journal":{"name":"Materials and Structures","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1617/s11527-024-02417-8.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials and Structures","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1617/s11527-024-02417-8","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Compressive strength of grouted concrete masonry is an important parameter to design reinforced/grouted concrete masonry walls. The design standards stipulate two methods to determine the compressive strength of masonry (1) using tabulated unit strength and mortar type, and (2) testing representative masonry prisms. The compressive strength prediction of grouted concrete masonry is influenced by compressive strength values of hollow blocks, mortar and grout, and their geometries. Therefore, a multi-level approach was employed in this study to improve the existing unit strength correlations of the standards for more reliable prediction of compressive strengths of grouted concrete masonry. The existing methods to determine the compressive strength of grouted masonry were critically appraised and a database of compression tests of grouted concrete masonry prisms/wallettes was developed. This database was then used to evaluate the correlations between the compressive strengths of block, mortar, grout and masonry. The applicability of existing unit strength correlations from the design standards and literature were assessed and their relevancy and limitations are highlighted. Subsequently, updated sets of unit strength correlations are proposed in this study, through statistical reliability analyses of the predictions against the experimental results included in the database. The proposed unit strength correlations were classified according to the mortar type/strengths (≤ 10 MPa and > 10 MPa). It has been shown that the new correlations are more structurally reliable than the existing unit strength correlations through comparing the 95th percentile error values.
期刊介绍:
Materials and Structures, the flagship publication of the International Union of Laboratories and Experts in Construction Materials, Systems and Structures (RILEM), provides a unique international and interdisciplinary forum for new research findings on the performance of construction materials. A leader in cutting-edge research, the journal is dedicated to the publication of high quality papers examining the fundamental properties of building materials, their characterization and processing techniques, modeling, standardization of test methods, and the application of research results in building and civil engineering. Materials and Structures also publishes comprehensive reports prepared by the RILEM’s technical committees.