Estimation of the prevalence of isolated inter-scalene compression from simultaneous arterial and venous photoplethysmography in patients referred for suspected thoracic outlet syndrome.

IF 2.3 4区 医学 Q3 BIOPHYSICS Physiological measurement Pub Date : 2024-08-02 DOI:10.1088/1361-6579/ad65b1
Simon Lecoq, Jeanne Hersant, Pierre Abraham
{"title":"Estimation of the prevalence of isolated inter-scalene compression from simultaneous arterial and venous photoplethysmography in patients referred for suspected thoracic outlet syndrome.","authors":"Simon Lecoq, Jeanne Hersant, Pierre Abraham","doi":"10.1088/1361-6579/ad65b1","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>In patients with suspected thoracic outlet syndrome (TOS), diagnosing inter-scalene compression could lead to minimally invasive treatments. During photo-plethysmography, completing a 30 s 90° abduction, external rotation ('surrender' position) by addition of a 15 s 90° antepulsion 'prayer' position, allows quantitative bilateral analysis of both arterial (A-PPG) and venous (V-PPG) results. We aimed at determining the proportion of isolated arterial compression with photo-plethysmography in TOS-suspected patients.<i>Approach.</i>We studied 116 subjects recruited over 4 months (43.3 ± 11.8 years old, 69% females). Fingertip A-PPG and forearm V-PPG were recorded on both sides at 125 Hz and 4 Hz respectively. A-PPG was converted to PPG amplitude and expressed as percentage of resting amplitude (% rest). V-PPG was expressed as percentage of the maximal value (% max) observed during the 'Surrender-Prayer' maneuver. Impairment of arterial inflow during the surrender (As+) or prayer (Ap+) phases were defined as a pulse-amplitude either <5% rest, or <25% rest. Incomplete venous emptying during the surrender (Vs+) or prayer (Vp+) phases were defined as V-PPG values either <70% max, or <87% max.<i>Main results.</i>Of the 16 possible associations of encodings, As - Vs - Ap - Vp- was the most frequent observation assumed to be a normal response. Isolated arterial inflow without venous outflow (As + Vs-) impairment in the surrender position was observed in 10.3% (95%CI: 6.7%-15.0%) to 15.1% (95%CI: 10.7%-20.4%) of limbs.<i>Significance.</i>Simultaneous A-PPG and V-PPG can discriminate arterial from venous compression and then potentially inter-scalene from other levels of compressions. As such, it opens new perspectives in evaluation and treatment of TOS.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ad65b1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.In patients with suspected thoracic outlet syndrome (TOS), diagnosing inter-scalene compression could lead to minimally invasive treatments. During photo-plethysmography, completing a 30 s 90° abduction, external rotation ('surrender' position) by addition of a 15 s 90° antepulsion 'prayer' position, allows quantitative bilateral analysis of both arterial (A-PPG) and venous (V-PPG) results. We aimed at determining the proportion of isolated arterial compression with photo-plethysmography in TOS-suspected patients.Approach.We studied 116 subjects recruited over 4 months (43.3 ± 11.8 years old, 69% females). Fingertip A-PPG and forearm V-PPG were recorded on both sides at 125 Hz and 4 Hz respectively. A-PPG was converted to PPG amplitude and expressed as percentage of resting amplitude (% rest). V-PPG was expressed as percentage of the maximal value (% max) observed during the 'Surrender-Prayer' maneuver. Impairment of arterial inflow during the surrender (As+) or prayer (Ap+) phases were defined as a pulse-amplitude either <5% rest, or <25% rest. Incomplete venous emptying during the surrender (Vs+) or prayer (Vp+) phases were defined as V-PPG values either <70% max, or <87% max.Main results.Of the 16 possible associations of encodings, As - Vs - Ap - Vp- was the most frequent observation assumed to be a normal response. Isolated arterial inflow without venous outflow (As + Vs-) impairment in the surrender position was observed in 10.3% (95%CI: 6.7%-15.0%) to 15.1% (95%CI: 10.7%-20.4%) of limbs.Significance.Simultaneous A-PPG and V-PPG can discriminate arterial from venous compression and then potentially inter-scalene from other levels of compressions. As such, it opens new perspectives in evaluation and treatment of TOS.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过对疑似胸廓出口综合征转诊患者同时进行动脉和静脉光电肌电图检查,估算孤立腕骨间压迫的发生率。
目的:对于疑似胸廓出口综合征(TOS)的患者,如果能诊断出椎骨间压迫,就可以进行微创治疗。在进行照相胸廓彩超检查时,完成 30 秒 90° 外展、外旋("投降 "体位),再加上 15 秒 90° 反外展 "祈祷 "体位,可对动脉(A-PPG)和静脉(V-PPG)结果进行双侧定量分析。我们的目的是通过光电搏动图确定疑似 TOS 患者中孤立动脉受压的比例:我们对历时 4 个月招募的 116 名受试者(43.3+/-11.8 岁,69% 为女性)进行了研究。分别以 125 Hz 和 4 Hz 的频率记录两侧指尖 A-PPG 和前臂 V-PPG。A-PPG 被转换为 PPG 振幅,并以静息振幅的百分比(%rest)表示。V-PPG 以 "投降-祈祷 "动作中观察到的最大值的百分比(%max)表示。投降(As+)或祈祷(Ap+)阶段的动脉流入量受损定义为脉搏振幅小于静息时的 5%或小于静息时的 25%。在投降(Vs+)或祈祷(Vp+)阶段,静脉排空不完全的定义是 V-PPG 值低于或低于 25%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
期刊最新文献
Predicting stroke volume variation using central venous pressure waveform: a deep learning approach. Recurrence quantification analysis of uterine vectormyometriogram reveals differences between normal-weight and overweight parturient women. Adaptive threshold algorithm for detecting EEG-interburst intervals in extremely preterm neonates. Cycle-frequency content EEG analysis improves the assessment of respiratory-related cortical activity. The impact of controlled breathing on autonomic nervous system modulation: analysis using phase-rectified signal averaging, entropy and heart rate variability.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1